9 resultados para HSM CIR VASC
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVE: To evaluate implant accuracy and cosmetic outcome of a new intraoperative patient-specific cranioplasty method after convexity meningioma resection. METHODS: The patient's own bone flap served as a template to mold a negative form with the use of polymethyl methacrylate (PMMA). The area of bone invasion was determined and broadly excised under white light illumination with a safety margin of at least 1 cm. The definitive replica was cast within the remaining bone flap frame and the imprint. Clinical and radiologic follow-up examinations were performed 3 months after surgery. RESULTS: Four women and two men (mean age 51.4 years ± 12.8) underwent reconstruction of bone flap defects after meningioma resection. Mean duration of intraoperative reconstruction of the partial bone flap defects was 19 minutes ± 4 (range 14-24 minutes). Implant sizes ranged from 17-35 cm(2) (mean size 22 cm(2) ± 8). Radiologic and clinical follow-up examinations revealed excellent implant alignment and favorable cosmesis (visual analogue scale for cosmesis [VASC] = 97 ± 5) in all patients. CONCLUSIONS: Patient-specific reconstruction of partial bone flap defects after convexity meningioma resection using the presented intraoperative PMMA cast method resulted in excellent bony alignment and a favorable cosmetic outcome. Relatively low costs and minimized operation time for adjustment and insertion of the cranioplasty implant justify use of this method in small bony defects as well.
Resumo:
All-trans retinoic acid (ATRA) plus anthracycline chemotherapy is the reference treatment of newly diagnosed acute promyelocytic leukemia (APL), whereas the role of cytosine arabinoside (AraC) remains disputed. We performed a joint analysis of patients younger than 65 years included in Programa para el Estudio de la Terapéutica en Hemopatía Maligna (PETHEMA) LPA 99 trial, where patients received no AraC in addition to ATRA, high cumulative dose idarubicin, and mitoxantrone, and APL 2000 trial, where patients received AraC in addition to ATRA and lower cumulative dose daunorubicin. In patients with white blood cell (WBC) count less than 10 x 10(9)/L, complete remission (CR) rates were similar, but 3-year cumulative incidence of relapse (CIR) was significantly lower in LPA 99 trial: 4.2% versus 14.3% (P = .03), although 3-year survival was similar in both trials. This suggested that AraC is not required in APL with WBC count less than 10 x 10(9)/L, at least in trials with high-dose anthracycline and maintenance treatment. In patients with WBC of 10 x 10(9)/L or more, however, the CR rate (95.1% vs 83.6% P = .018) and 3-year survival (91.5% vs 80.8%, P = .026) were significantly higher in APL 2000 trial, and there was a trend for lower 3-year CIR (9.9% vs 18.5%, P = .12), suggesting a beneficial role for AraC in those patients.
Resumo:
Aims: Newer-generation everolimus-eluting stents (EES) have been shown to improve clinical outcomes compared with early-generation sirolimus-eluting (SES) and paclitaxel-eluting stents (PES) in patients undergoing percutaneous coronary intervention (PCI). Whether this benefit is maintained among patients with saphenous vein graft (SVG) disease remains controversial. Methods and results: We assessed cumulative incidence rates (CIR) per 100 patient years after inverse probability of treatment weighting to compare clinical outcomes. The pre-specified primary endpoint was the composite of cardiac death, myocardial infarction (MI), and target vessel revascularisation (TVR). Out of 12,339 consecutively treated patients, 288 patients (5.7%) underwent PCI of at least one SVG lesion with EES (n=127), SES (n=103) or PES (n=58). Up to four years, CIR of the primary endpoint were 58.7 for EES, 45.2 for SES and 45.6 for PES with similar adjusted risks between groups (EES vs. SES; HR 0.94, 95% CI: 0.55-1.60, EES vs. PES; HR 1.07, 95% CI: 0.60-1.91). Adjusted risks showed no significant differences between stent types for cardiac death, MI and TVR. Conclusions: Among patients undergoing PCI for SVG lesions, newer-generation EES have similar safety and efficacy to early-generation SES and PES during long-term follow-up to four years.
Resumo:
OBJECTIVES To report a 10-year single center experience with Amplatzer devices for left atrial appendage (LAA) occlusion. BACKGROUND Intermediate-term outcome data following LAA occlusion are scarce. METHODS Short- and intermediate-term outcomes of patients who underwent LAA occlusion were assessed. All procedures were performed under local aesthesia without transesophageal echocardiography. Patients were discharged on acetylsalicylic acid and clopidogrel for 1-6 months. RESULTS LAA occlusion was attempted in 152 patients (105 males, age 72 ± 10 years, CHA2 DS2 -Vasc-score 3.4 ± 1.7, HAS-BLED-score 2.4 ± 1.2). Nondedicated devices were used in 32 patients (21%, ND group) and dedicated Amplatzer Cardiac Plugs were used in 120 patients (79%, ACP group). A patent foramen ovale or atrial septal defect was used for left atrial access and closed at the end of LAA occlusion in 40 patients. The short-term safety endpoints (procedural complications, bleeds) occurred in 15 (9.8%) and the efficacy endpoints (death, stroke, systemic embolization) in 0 patients. Device embolization occurred more frequently in the ND as compared to the ACP group (5 patients or 12% vs. 2 patients or 2%). Mean intermediate-term follow up of the study population was 32 months (range 1-120). Late deaths occurred in 15 patients (5 cardiovascular, 7 noncardiac, 3 unexplained). Neurologic events occurred in 2, peripheral embolism in 1, and major bleeding in 4 patients. The composite efficacy and safety endpoint occurred in 7% and 12% of patients. CONCLUSION LAA closure may be a good alternative to oral anticoagulation. This hypothesis needs to be tested in a randomized clinical trial to ensure that all potential biases of this observational study are accounted for.
Resumo:
OBJECTIVE To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users. METHODS Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280 × 720, 640 × 480, 320 × 240, 160 × 120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0-500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed. RESULTS Higher frame rate (>7 fps), higher camera resolution (>640 × 480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032). CONCLUSION Webcameras have the potential to improve telecommunication of hearing-impaired individuals.
Resumo:
Drugs may stimulate the immune system by forming stable new antigenic complexes consisting of the drug or drug metabolite which is covalently bound to a protein or peptide (hapten-carrier complex). Both, B- and T-cell immunity may arise, the latter directed to hapten modified peptides presented by HLA molecules. Beside this immunological stimulation, drugs can also stimulate the immune system through binding by non-covalent bonds to proteins like immune receptors. This so-called “pharmacological interaction with immune receptors” concept (“p-i concept”) may occur with HLA or TCR molecules themselves (p-i HLA or p-i TCR), and not the immunogenic peptide. It is a type of “off-target” activity of the drug on immune receptors, but more complex as various cell types, cell interactions and functionally different T cells are involved. In this review the conditions which lead to activation of T cells by p-i are discussed: important factors for a functional consequence of drug binding is the location of binding (p-i HLA or p-i TCR); the exact site within these immune receptors; the affinity of binding and the finding that p-i HLA can stimulate the immune system like an allo-allele. The p-i concept is able to solve some puzzles of drug hypersensitivity reactions and are a basis to better treat and potentially avoid drug hypersensitivity reactions. Moreover, the p-i concept shows that in contrast to previous beliefs small molecules do interact with immune receptors with functional consequence. But these interactions are not based on “immune recognition”, are at odds with some immunological concepts, but may nevertheless open new possibilities to understand and even treat immune reactions
Resumo:
Indoor localization systems become more interesting for researchers because of the attractiveness of business cases in various application fields. A WiFi-based passive localization system can provide user location information to third-party providers of positioning services. However, indoor localization techniques are prone to multipath and Non-Line Of Sight (NLOS) propagation, which lead to significant performance degradation. To overcome these problems, we provide a passive localization system for WiFi targets with several improved algorithms for localization. Through Software Defined Radio (SDR) techniques, we extract Channel Impulse Response (CIR) information at the physical layer. CIR is later adopted to mitigate the multipath fading problem. We propose to use a Nonlinear Regression (NLR) method to relate the filtered power information to propagation distances, which significantly improves the ranging accuracy compared to the commonly used log-distance path loss model. To mitigate the influence of ranging errors, a new trilateration algorithm is designed as well by combining Weighted Centroid and Constrained Weighted Least Square (WC-CWLS) algorithms. Experiment results show that our algorithm is robust against ranging errors and outperforms the linear least square algorithm and weighted centroid algorithm.
Resumo:
Previous cancer vaccination trials often aimed to activate CD8(+) cytotoxic T-cell (CTL) responses with short (8-10mer) peptides and targeted CD4(+) helper T cells (TH) with HLA class II-binding longer peptides (12-16 mer) that were derived from tumor antigens. Accordingly, a study of immunomonitoring focused on the detection of CTL responses to the short, and TH responses to the long, peptides. The possible induction of concurrent TH responses to short peptides was widely neglected. In a recent phase I vaccination trial, 53 patients with different solid cancers were vaccinated with EMD640744, a cocktail of five survivin-derived short (9- or 10-mer) peptides in Montanide ISA 51VG. We monitored 49 patients and found strong CD8(+) T-cell responses in 63% of the patients. In addition, we unexpectedly found CD4(+) TH cell responses against at least two of the five short peptides in 61% (23/38) of the patients analyzed. The two peptides were recognized by HLA-DP4- and HLA-DR-restricted TH1 cells. Some short peptide-reactive (sp)CD4 T cells showed high functional avidity. Here, we show that a short peptide vaccine is able to activate a specific CD4(+) T-cell repertoire in many patients, facilitating a strong combined CD4(+)/CD8(+) T-cell response. Cancer Immunol Res; 4(1); 18-25. ©2015 AACR.