21 resultados para HIGH-VELOCITY

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: New equipment and techniques in winter sports, such as carving skis and snowboards, have brought up new trauma patterns into the spectrum of leisure trauma. The injuries resemble high-energy trauma known from road crashes. The aim of the present study was to assess the incidence of acute traumatic descending aortic rupture in recreational skiing-crashes. MATERIAL: Between January 1995 and December 2004, 22 patients were admitted to our hospital for aortic rupture. Four patients had skiing crashes (18.2%). Mean age was 31 years, all patients were male. In two cases, aortic rupture was associated with fractures of the upper and lower extremities. One patient additionally had a cerebral contusion with an initial Glasgow Coma Scale score of 13. In two patients, isolated aortic rupture was diagnosed. RESULTS: Two patients were treated by graft interposition, and one by endograft. One patient arrived under mechanical resuscitation without blood pressure. He died at admission. He had been observed for 5 hours in another hospital, complaining of severe intrascapular back pain, before transport to our trauma unit for unknown bleeding. In the other three cases, treatment was successful. CONCLUSION: Rescue services and paramedics should be aware of this new type of injury. Acute aortic rupture has to be considered as possible injury in high velocity skiing crashes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Arterio-venous malformations (AVMs) are congenital vascular malformations (CVMs) that result from birth defects involving the vessels of both arterial and venous origins, resulting in direct communications between the different size vessels or a meshwork of primitive reticular networks of dysplastic minute vessels which have failed to mature to become 'capillary' vessels termed "nidus". These lesions are defined by shunting of high velocity, low resistance flow from the arterial vasculature into the venous system in a variety of fistulous conditions. A systematic classification system developed by various groups of experts (Hamburg classification, ISSVA classification, Schobinger classification, angiographic classification of AVMs,) has resulted in a better understanding of the biology and natural history of these lesions and improved management of CVMs and AVMs. The Hamburg classification, based on the embryological differentiation between extratruncular and truncular type of lesions, allows the determination of the potential of progression and recurrence of these lesions. The majority of all AVMs are extra-truncular lesions with persistent proliferative potential, whereas truncular AVM lesions are exceedingly rare. Regardless of the type, AV shunting may ultimately result in significant anatomical, pathophysiological and hemodynamic consequences. Therefore, despite their relative rarity (10-20% of all CVMs), AVMs remain the most challenging and potentially limb or life-threatening form of vascular anomalies. The initial diagnosis and assessment may be facilitated by non- to minimally invasive investigations such as duplex ultrasound, magnetic resonance imaging (MRI), MR angiography (MRA), computerized tomography (CT) and CT angiography (CTA). Arteriography remains the diagnostic gold standard, and is required for planning subsequent treatment. A multidisciplinary team approach should be utilized to integrate surgical and non-surgical interventions for optimum care. Currently available treatments are associated with significant risk of complications and morbidity. However, an early aggressive approach to elimiate the nidus (if present) may be undertaken if the benefits exceed the risks. Trans-arterial coil embolization or ligation of feeding arteries where the nidus is left intact, are incorrect approaches and may result in proliferation of the lesion. Furthermore, such procedures would prevent future endovascular access to the lesions via the arterial route. Surgically inaccessible, infiltrating, extra-truncular AVMs can be treated with endovascular therapy as an independent modality. Among various embolo-sclerotherapy agents, ethanol sclerotherapy produces the best long term outcomes with minimum recurrence. However, this procedure requires extensive training and sufficient experience to minimize complications and associated morbidity. For the surgically accessible lesions, surgical resection may be the treatment of choice with a chance of optimal control. Preoperative sclerotherapy or embolization may supplement the subsequent surgical excision by reducing the morbidity (e.g. operative bleeding) and defining the lesion borders. Such a combined approach may provide an excellent potential for a curative result. Conclusion. AVMs are high flow congenital vascular malformations that may occur in any part of the body. The clinical presentation depends on the extent and size of the lesion and can range from an asymptomatic birthmark to congestive heart failure. Detailed investigations including duplex ultrasound, MRI/MRA and CT/CTA are required to develop an appropriate treatment plan. Appropriate management is best achieved via a multi-disciplinary approach and interventions should be undertaken by appropriately trained physicians.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT: Isolated non-skeletal injuries of the cervical spine are rare and frequently missed. Different evaluation algorithms for C-spine injuries, such as the Canadian C-spine Rule have been proposed, however with strong emphasis on excluding osseous lesions. Discoligamentary injuries may be masked by unique clinical situations presenting to the emergency physician. We report on the case of a 28-year-old patient being admitted to our emergency department after a snowboarding accident, with an assumed hyperflexion injury of the cervical spine. During the initial clinical encounter the only clinical finding the patient demonstrated, was a burning sensation in the palms bilaterally. No neck pain could be elicited and the patient was not intoxicated and did not have distracting injuries. Since the patient described a fall prevention attempt with both arms, a peripheral nerve contusion was considered as a differential diagnosis. However, a high level of suspicion and the use of sophisticated imaging (MRI and CT) of the cervical spine, ultimately led to the diagnosis of a traumatic disc rupture at the C5/6 level. The patient was subsequently treated with a ventral microdiscectomy with cage interposition and ventral plate stabilization at the C5/C6 level and could be discharged home with clearly improving symptoms and without further complications.This case underlines how clinical presentation and extent of injury can differ and it furthermore points out, that injuries contracted during alpine snow sports need to be considered high velocity injuries, thus putting the patient at risk for cervical spine trauma. In these patients, especially when presenting with an unclear neurologic pattern, the emergency doctor needs to be alert and may have to interpret rigid guidelines according to the situation. The importance of correctly using CT and MRI according to both - standardized protocols and the patient's clinical presentation - is crucial for exclusion of C-spine trauma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Vibrations, electromagnetic oscillations, and temperature drifts are among the main reasons for dephasing in matter-wave interferometry. Sophisticated interferometry experiments, e.g., with ions or heavy molecules, often require integration times of several minutes due to the low source intensity or the high velocity selection. Here we present a scheme to suppress the influence of such dephasing mechanisms—especially in the low-frequency regime—by analyzing temporal and spatial particle correlations available in modern detectors. Such correlations can reveal interference properties that would otherwise be washed out due to dephasing by external oscillating signals. The method is shown experimentally in a biprism electron interferometer where a perturbing oscillation is artificially introduced by a periodically varying magnetic field. We provide a full theoretical description of the particle correlations where the perturbing frequency and amplitude can be revealed from the disturbed interferogram. The original spatial fringe pattern without the perturbation can thereby be restored. The technique can be applied to lower the general noise requirements in matter-wave interferometers. It allows for the optimization of electromagnetic shielding and decreases the efforts for vibrational or temperature stabilization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Excitation of tert-butylnitrite into the first and second UV absorption bands leads to efficient dissociation into the fragment radicals NO and tert-butoxy in their electronic ground states (2)Π and (2)E, respectively. Velocity distributions and angular anisotropies for the NO fragment in several hundred rotational and vibrational quantum states were obtained by velocity-map imaging and the recently developed 3D-REMPI method. Excitation into the well resolved vibronic progression bands (k = 0, 1, 2) of the NO stretch mode in the S(1) ← S(0) transition produces NO fragments mostly in the vibrational state with v = k, with smaller fractions in v = k - 1 and v = k - 2. It is concluded that dissociation occurs on the purely repulsive PES of S(1) without barrier. All velocity distributions from photolysis via the S(1)(nπ*) state are monomodal and show high negative anisotropy (β ≈ -1). The rotational distributions peak near j = 30.5 irrespective of the vibronic state S(1)(k) excited and the vibrational state v of the NO fragment. On average 46% of the excess energy is converted to kinetic energy, 23% and 31% remain as internal energy in the NO fragment and the t-BuO radical, respectively. Photolysis via excitation into the S(2) ← S(0) transition at 227 nm yields NO fragments with about equal populations in v = 0 and v = 1. The rotational distributions have a single maximum near j = 59.5. The velocity distributions are monomodal with positive anisotropy β ≈ 0.8. The average fractions of the excess energy distributed into translation, internal energy of NO, and internal energy of t-BuO are 39%, 23%, and 38%, respectively. In all cases ∼8500 cm(-1) of energy remain in the internal degrees of freedom of the t-BuO fragment. This is mostly assigned to rotational energy. An ab initio calculation of the dynamic reaction path shows that not only the NO fragment but also the t-BuO fragment gain large angular momentum during dissociation on the purely repulsive potential energy surface of S(2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: A single high loading dose of 25 mg/kg caffeine has been shown to be effective for the prevention of apnoea, but may result in considerable reductions in blood flow velocity (BFV) in cerebral and intestinal arteries. OBJECTIVE: To assess the effects of two loading doses of 12.5 mg/kg caffeine given four hours apart on BFV in cerebral and intestinal arteries, left ventricular output (LVO), and plasma caffeine concentrations in preterm infants. DESIGN: Sixteen preterm neonates of <34 weeks gestation were investigated one hour after the first oral dose and one, two, and 20 hours after the second dose by Doppler sonography. RESULTS: The mean (SD) plasma caffeine concentrations were 31 (7) and 29 (7) mg/l at two and 20 hours respectively after the second dose. One hour after the first dose, none of the circulatory variables had changed significantly. One hour after the second caffeine dose, mean BFV in the internal carotid artery and anterior cerebral artery showed significant reductions of 17% and 19% (p = 0.01 and p = 0.003 respectively). BFV in the coeliac artery and superior mesenteric artery, LVO, PCO2, and respiratory rate had not changed significantly. Total vascular resistance, calculated as the ratio of mean blood pressure to LVO, had increased significantly one and two hours after the second dose (p = 0.049 and p = 0.023 respectively). CONCLUSION: A divided high loading dose of 25 mg/kg caffeine given four hours apart had decreased BFV in cerebral arteries after the second dose, whereas BFV in intestinal arteries and LVO were not affected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cationic and anionic electrophoretic mobilization for focusing of hemoglobins (Hb's) in the presence of 100 carrier ampholytes covering a pI range of 6.00-7.98 was studied by computer simulation at a constant current density of 300 A/m(2). Electropherograms that would be produced by whole column imaging and by single detectors placed at different locations along the focusing column are presented. Upon mobilization, peak heights of the Hb zones decrease, but the zones retain a relatively sharp constant profile and are migrating at a constant velocity. A further peak decrease occurs during readjustment at the locations of the original buffer/column interfaces, indicating that detection sensitivity is the lowest at these locations. An anionic carrier ampholyte mobility smaller than that of its cationic species produces a cathodic drift which is smaller than the transport rate used for electrophoretic mobilization. Compared to the case with equal mobilities of carrier ampholyte species, a small increase (decrease) is predicted for the cationic (anionic) mobilization rate within the focusing column. Simulation data suggest that electrophoretic mobilization after focusing and focusing with concurrent electrophoretic mobilization are comparable isotachophoretic processes that occur when there is an uninterrupted flux of an ion through the focusing column. Cathodic drift caused by unequal mobilities of the species of carrier ampholytes, electrophoretic mobilization, and decomposition occurring at the pH gradient edges are related electrophoretic processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulse wave velocity (PWV) is a surrogate of arterial stiffness and represents a non-invasive marker of cardiovascular risk. The non-invasive measurement of PWV requires tracking the arrival time of pressure pulses recorded in vivo, commonly referred to as pulse arrival time (PAT). In the state of the art, PAT is estimated by identifying a characteristic point of the pressure pulse waveform. This paper demonstrates that for ambulatory scenarios, where signal-to-noise ratios are below 10 dB, the performance in terms of repeatability of PAT measurements through characteristic points identification degrades drastically. Hence, we introduce a novel family of PAT estimators based on the parametric modeling of the anacrotic phase of a pressure pulse. In particular, we propose a parametric PAT estimator (TANH) that depicts high correlation with the Complior(R) characteristic point D1 (CC = 0.99), increases noise robustness and reduces by a five-fold factor the number of heartbeats required to obtain reliable PAT measurements.