34 resultados para HEALTHY-ADULTS
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Our understanding of regional filling of the lung and regional ventilation distribution is based on studies using stepwise inhalation of radiolabelled tracer gases, magnetic resonance imaging and positron emission tomography. We aimed to investigate whether these differences in ventilation distribution at different end-expiratory levels (EELs) and tidal volumes (V (T)s) held also true during tidal breathing. Electrical impedance tomography (EIT) measurements were performed in ten healthy adults in the right lateral position. Five different EELs with four different V (T)s at each EEL were tested in random order, resulting in 19 combinations. There were no measurements for the combination of the highest EEL/highest V (T). EEL and V (T) were controlled by visual feedback based on airflow. The fraction of ventilation directed to different slices of the lung (VENT(RL1)-VENT(RL8)) and the rate of the regional filling of each slice versus the total lung were analysed. With increasing EEL but normal tidal volume, ventilation was preferentially distributed to the dependent lung and the filling of the right and left lung was more homogeneous. With increasing V (T) and maintained normal EEL (FRC), ventilation was preferentially distributed to the dependent lung and regional filling became more inhomogeneous (p < 0.05). We could demonstrate that regional and temporal ventilation distribution during tidal breathing was highly influenced by EEL and V (T).
Resumo:
Respiratory system input impedance (Zrs) at low to medium frequencies below 100 Hz, and study of its volume dependence, have been used extensively to quantify airway and tissue mechanics. Zrs at high oscillation frequencies including the first antiresonant frequency (far,1) may contain important information about airway mechanics. Changes in high-frequency Zrs with lung volume have not been studied. The volume-dependent behavior of high-frequency Zrs, specifically far,1 and respiratory system resistance at first antiresonance (Rrs(far,1)), was characterized in 16 healthy adults. Zrs was measured with a forced oscillation signal (5-302.5 Hz) through a wavetube setup. To track Zrs, subjects performed slow deep inspiratory and expiratory maneuvers over 30-s measurements, during which average impedance was calculated over 0.4-s intervals, with successive overlapping estimates every 0.156 s. Flow was measured using a pneumotachometer and integrated to obtain volume. Transpulmonary pressure dependence (Ptp) of Zrs was separately determined in five subjects. Both far,1 and Rrs(far,1) decreased with increasing lung volume and Ptp, consistent with an increase in airway caliber and decreased airway wall compliance as volume increased. These characterizations provide insight into airway mechanics, and are furthermore a necessary first step toward determining whether volume dependence of the first antiresonance is altered in disease.
Resumo:
Moraxella catarrhalis is a major mucosal pathogen of the human respiratory tract, but the mucosal immune response directed against surface components of this organism has not been characterized in detail. The aim of this study was to investigate the salivary immunoglobulin A (IgA) response toward outer membrane proteins (OMP) of M. catarrhalis in healthy adults, the group of individuals least likely to be colonized and thus most likely to display mucosal immunity. Unstimulated saliva samples collected from 14 healthy adult volunteers were subjected to IgA immunoblot analysis with OMP preparations of M. catarrhalis strain O35E. Immunoblot analysis revealed a consistent pattern of IgA reactivity, with the appearance of five major bands located at >250, 200, 120, 80, and 60 kDa. Eleven (79%) of 14 saliva samples elicited reactivity to all five bands. Immunoblot analysis with a set of isogenic knockout mutants lacking the expression of individual OMP was used to determine the identities of OMP giving rise to IgA bands. Human saliva was shown consistently to exhibit IgA-binding activity for oligomeric UspA2 (>250 kDa), hemagglutinin (200 kDa), monomeric UspA1 (120 kDa), transferrin-binding protein B (TbpB), monomeric UspA2, CopB, and presumably OMP CD. TbpB, oligomeric UspA2, and CopB formed a cluster of bands at about 80 kDa. These data indicate that the human salivary IgA response is directed consistently against a small number of major OMP, some of which are presently considered vaccine candidates. The functional properties of these mucosal antibodies remain to be elucidated.
Resumo:
BACKGROUND: Our aim was to investigate the influence of age and gender on intrarenal resistance index (RI) measurements in 78 healthy subjects (46 males, 32 females; group 1) and 35 subjects (group 2) with fatty liver disease (28 males and 7 females). SUBJECTS AND METHODS: First, each subject underwent a conventional abdominal ultrasound examination. Then, intrarenal RI values were determined from three distinct interlobar and cortical arteries respectively on both kidneys. The correlation of intrarenal RI with age and gender as a variable was statistically evaluated by linear regression. RESULTS: In group 1, the variables gender, kidney region and comparison of right versus left kidney had no significant effect on intrarenal RI (p>0.05). The variable age, on the other hand, showed a significant positive correlation on all four defined measuring points (p<0.01) with linear correlation coefficients of r = 0.26 (left kidney, central) to r = 0.37 (right kidney, cortical). Therefore normal RI values at ages 25, 45, 65 years could be defined as 0.59, 0.61 and 0.63, respectively. Age dependency can thus be expressed as a function with the formula y = 0.565 + 0.001.x. Patients with fatty liver disease showed age dependency on renal RI (p<0.01) as well. CONCLUSION: In accordance with other studies, the influence of age on intrarenal RI measurement is significant in healthy subjects. Intrarenal RI values from subjects with a fatty liver disease showed age dependency as well. Therefore it is necessary to consider the age of the examined person to interpret RI values correctly.
Resumo:
Recent evidence suggests that individual differences in physical activity (PA) may be associated with individual differences in white matter microstructure and with grey matter volume of the hippocampus. Therefore, this study investigated the association between PA and white matter microstructure of pathways connecting to the hippocampus. A total of 33 young, healthy adults underwent magnetic resonance imaging (MRI). High angular resolution diffusion-weighted imaging and multi-component relaxometry MRI scans (multi-component driven equilibrium pulse observation of T1 and T2) were acquired for each participant. Activity levels (AL) of participants were calculated from 72-h actigraphy recordings. Tractography using the damped Richardson Lucy algorithm was used to reconstruct the fornix and bilateral parahippocampal cinguli (PHC). The mean fractional anisotropy (FA) and the myelin water fraction (MWF), a putative marker of myelination, were determined for each pathway. A positive correlation between both AL and FA and between AL and MWF were hypothesized for the three pathways. There was a selective positive correlation between AL and MWF in the right PHC (r = 0.482, p = 0.007). Thus, our results provide initial in vivo evidence for an association between myelination of the right PHC and PA in young healthy adults. Our results suggest that MWF may not only be more specific, but also more sensitive than FA to detect white matter microstructural alterations. If PA was to induce structural plasticity of the right PHC this may contribute to reverse structural alterations of the right PHC in neuropsychiatric disorder with hippocampal pathologies.
Resumo:
This study aimed to measure serum concentrations of five lectin-pathway components, mannan-binding lectin (MBL), M-ficolin, L-ficolin, H-ficolin, and MBL-associated serine protease-2 (MASP-2), in healthy neonates and children, to determine if they change with age and to compare them with serum concentrations in healthy adults. Concentrations were measured in 141 preterm and 30 term neonates, in 120 children including infants and adolescents, and in 350 adults (97 for L-ficolin) by inhouse time-resolved immunofluorometric assays or commercially available enzyme-linked immunosorbent assays. The adjacent categories method applying Wilcoxon-Mann-Whitney tests was used to determine age categories where concentrations differed significantly. Displaying serum concentration vs. age, an inverted-U shape (higher concentrations in children than in neonates and adults) was found for MBL and the ficolins, and an S-shape for MASP-2. Serum concentrations of all five lectin-pathway components were significantly lower in preterm neonates <32-wk gestational age compared to older neonates, infants, and children. Only M-ficolin in children >1 yr and H-ficolin in term neonates and in children were found to be comparable with adult values. MBL, M-, L-, and H-ficolin, and MASP-2 serum concentrations show important changes with age. The respective normal ranges for adults should not be used in the pediatric population. The age-specific pediatric ranges established here may be used instead.
Resumo:
PURPOSE: To perform baseline T(2) mapping of the hips of healthy volunteers, focusing on topographic variation, because no detailed study has involved hips. T(2) mapping is a quantitative magnetic resonance imaging (MRI) technique that evaluates cartilage matrix components. MATERIALS AND METHODS: Hips of 12 healthy adults (six men and six women; mean age = 29.5 +/- 4.9 years) were studied with a 3.0-Tesla MRI system. T(2) measurement in the oblique-coronal plane used a multi-spin-echo (MSE) sequence. Femoral cartilage was divided into 12 radial sections; acetabular cartilage was divided into six radial sections, and each section was divided into two layers representing the superficial and deep halves of the cartilage. T(2) of these sections and layers were measured. RESULTS: Femoral cartilage T(2) was the shortest (-20 degrees to 20 degrees and -10 degrees to 10 degrees , superficial and deep layers), with an increase near the magic angle (54.7 degrees ). Acetabular cartilage T(2) in both layers was shorter in the periphery than the other parts, especially at 20 degrees to 30 degrees . There were no significant differences in T(2) between right and left hips or between men and women. CONCLUSION: Topographic variation exists in hip cartilage T(2) in young, healthy adults. These findings should be taken into account when T(2) mapping is applied to patients with degenerative cartilage. J. Magn. Reson. Imaging 2007;26:165-171. (c) 2007 Wiley-Liss, Inc.
Resumo:
BACKGROUND AND OBJECTIVES We investigated the effect of different breathing aids on ventilation distribution in healthy adults and subjects with cystic fibrosis (CF). METHODS In 11 healthy adults and 9 adults with CF electrical impedance tomography measurements were performed during spontaneous breathing, continuous positive airway pressure (CPAP) and positive expiratory pressure (PEP) therapy randomly applied in upright and lateral position. Spatial and temporal ventilation distribution was assessed. RESULTS The proportion of ventilation directed to the dependent lung significantly increased in lateral position compared to upright in healthy and CF. This effect was enhanced with CPAP but neutralised with PEP, whereas the effect of PEP was larger in the healthy group. Temporal ventilation distribution showed exactly the opposite with homogenisation during CPAP and increased inhomogeneity with PEP. CONCLUSIONS PEP shows distinct differences to CPAP with respect to its impact on ventilation distribution in healthy adults and CF subjects EIT might be used to individualise respiratory physiotherapy.
Resumo:
Patent foramen ovale is found in 24% of healthy adults and 38% of patients with cryptogenic stroke. This ratio and case reports indicate that patent foramen ovale and stroke are associated, probably because of paradoxical embolism. In healthy people with patent foramen ovale, embolic events are not more frequent than in controls, and therefore no primary prevention is needed. However, once ischaemic events occur, the risk of recurrence is substantial and prevention becomes an issue. Acetylsalicylic acid and warfarin reduce this risk to the same level as in patients without patent foramen ovale. Patent foramen ovale with a coinciding atrial septal aneurysm, spontaneous or large right-to-left shunt, or multiple ischaemic events potentiates the risk of recurrence. Transcatheter device closure has therefore become an intriguing addition to medical treatment, but its therapeutic value still needs to be confirmed by randomised-controlled trials.
Resumo:
Noninvasive imaging of atherosclerosis is being increasingly used in clinical practice, with some experts recommending to screen all healthy adults for atherosclerosis and some jurisdictions mandating insurance coverage for atherosclerosis screening. Data on the impact of such screening have not been systematically synthesized.
Tidal volume single breath washout of two tracer gases--a practical and promising lung function test
Resumo:
Background Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF6) and helium (He) using an ultrasonic flowmeter (USFM). Methods The tracer gas mixture contained 5% SF6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. Results USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. Conclusion The USFM accurately measured relative changes in SF6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF6 and He washout patterns during tidal breathing.
Resumo:
Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.
Resumo:
Background For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N2)MBW system. Methods The N2MBW setup indirectly measures the N2 fraction (FN2) from main-stream carbon dioxide (CO2) and side-stream oxygen (O2) signals: FN2 = 1−FO2−FCO2−FArgon. For in vitro N2MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and FCO2. In vivo N2MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N2MBW outcome was functional residual capacity (FRC). We assessed in vitro error (√[difference]2) between measured and model FRC (100–4174 mL), and error between tests of in vivo FRC, lung clearance index (LCI), and normalized phase III slope indices (Sacin and Scond). Results The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD) error was 2.3 (1.7)%. In 500 to 4174 mL FRCs, 121 (98%) of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2)%. LCI was the most reproducible ventilation inhomogeneity index. Conclusion The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N2MBW system reliably measures lung volumes and delivers reproducible LCI values.
Resumo:
The encoding of verbal stimuli elicits left-lateralized activation patterns within the medial temporal lobes in healthy adults. In our study, patients with left- and right-sided temporal lobe epilepsy (LTLE, RTLE) were investigated during the encoding and retrieval of word-pair associates using functional magnetic resonance imaging. Functional asymmetry of activation patterns in hippocampal, inferior frontal, and temporolateral neocortical areas associated with language functions was analyzed. Hippocampal activation patterns in patients with LTLE were more right-lateralized than those in patients with RTLE (P<0.05). There were no group differences with respect to lateralization in frontal or temporolateral regions of interest (ROIs). For both groups, frontal cortical activation patterns were significantly more left-lateralized than hippocampal patterns (P<0.05). For patients with LTLE, there was a strong trend toward a difference in functional asymmetry between the temporolateral and hippocampal ROIs (P=0.059). A graded effect of epileptic activity on laterality of the different regional activation patterns is discussed.
Resumo:
In adults the contour analysis of peripheral pressure waves in the upper limb reflects central aortic stiffness. Here, we wanted to demonstrate the appropriateness of pulse contour analysis to assess large artery stiffness in children. Digital volume pulse analysis, with the computation of the stiffness index and pulse wave velocity between carotid and femoral artery, were simultaneously determined in 79 healthy children between 8 years and 15 years (mean age 11.4 years, 32 girls). The stiffness index of 42 healthy adults (mean age 45.6 years, 26 women) served as control. Pulse wave velocity between carotid and femoral artery was directly correlated with systolic pressure and mean blood pressure, as well as with pulse pressure. The results from the stiffness index of children revealed the expected values extrapolated from the linear regression of adulthood stiffness index vs. age. Childhood stiffness index positively correlated with pulse wave velocity (r(2) = 0.07, P = 0.02) but not with blood pressure parameters. The exclusion of individuals with an increased vascular tone, as indicated by a reflexion index > 90%, improved the correlation between stiffness index and pulse wave velocity (r(2) = 0.13, P = 0.001). Our data indicate that digital volume pulse-based analysis has limitations if compared with pulse wave velocity to measure arterial stiffness, mostly in patients with a high vascular tone.