2 resultados para H-infinity control design

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Classically, clinical trials are based on the placebo-control design. Our aim was to analyze the placebo effect in Huntington's disease. METHODS Placebo data were obtained from an international, longitudinal, placebo-controlled trial for Huntington's disease (European Huntington's Disease Initiative Study Group). One-hundred and eighty patients were evaluated using the Unified Huntington Disease Rating Scale over 36 months. A placebo effect was defined as an improvement of at least 50% over baseline scores in the Unified Huntington Disease Rating Scale, and clinically relevant when at least 10% of the population met it. RESULTS Only behavior showed a significant placebo effect, and the proportion of the patients with placebo effect ranged from 16% (first visit) to 41% (last visit). Nondepressed patients with better functional status were most likely to be placebo-responders over time. CONCLUSIONS In Huntington's disease, behavior seems to be more vulnerable to placebo than overall motor function, cognition, and function

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Short-acting agents for neuromuscular block (NMB) require frequent dosing adjustments for individual patient's needs. In this study, we verified a new closed-loop controller for mivacurium dosing in clinical trials. METHODS: Fifteen patients were studied. T1% measured with electromyography was used as input signal for the model-based controller. After induction of propofol/opiate anaesthesia, stabilization of baseline electromyography signal was awaited and a bolus of 0.3 mg kg-1 mivacurium was then administered to facilitate endotracheal intubation. Closed-loop infusion was started thereafter, targeting a neuromuscular block of 90%. Setpoint deviation, the number of manual interventions and surgeon's complaints were recorded. Drug use and its variability between and within patients were evaluated. RESULTS: Median time of closed-loop control for the 11 patients included in the data processing was 135 [89-336] min (median [range]). Four patients had to be excluded because of sensor problems. Mean absolute deviation from setpoint was 1.8 +/- 0.9 T1%. Neither manual interventions nor complaints from the surgeons were recorded. Mean necessary mivacurium infusion rate was 7.0 +/- 2.2 microg kg-1 min-1. Intrapatient variability of mean infusion rates over 30-min interval showed high differences up to a factor of 1.8 between highest and lowest requirement in the same patient. CONCLUSIONS: Neuromuscular block can precisely be controlled with mivacurium using our model-based controller. The amount of mivacurium needed to maintain T1% at defined constant levels differed largely between and within patients. Closed-loop control seems therefore advantageous to automatically maintain neuromuscular block at constant levels.