60 resultados para Gross output

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 52-yr-old man presented with hematuria and clot retention. He had undergone simultaneous pancreas-kidney transplantation with exocrine pancreas bladder drainage 16 yr ago. The patient suffered from progressive transplant kidney failure with gradually decreasing urine output and needed hemodialysis every other day. Gross hematuria persisted after removal of all blood clots. Cystoscopy showed multiple small, flat ulcers of the bladder mucosa. Some bled discretely and were coagulated cautiously. However, hematuria was refractory to multiple urological interventions, which eventually necessitated an enteric diversion of the exocrine pancreas. Hematuria ceased following an uneventful postoperative course.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial pressure-based cardiac output monitors (APCOs) are increasingly used as alternatives to thermodilution. Validation of these evolving technologies in high-risk surgery is still ongoing. In liver transplantation, FloTrac-Vigileo (Edwards Lifesciences) has limited correlation with thermodilution, whereas LiDCO Plus (LiDCO Ltd.) has not been tested intraoperatively. Our goal was to directly compare the 2 proprietary APCO algorithms as alternatives to pulmonary artery catheter thermodilution in orthotopic liver transplantation (OLT). The cardiac index (CI) was measured simultaneously in 20 OLT patients at prospectively defined surgical landmarks with the LiDCO Plus monitor (CI(L)) and the FloTrac-Vigileo monitor (CI(V)). LiDCO Plus was calibrated according to the manufacturer's instructions. FloTrac-Vigileo did not require calibration. The reference CI was derived from pulmonary artery catheter intermittent thermodilution (CI(TD)). CI(V)-CI(TD) bias ranged from -1.38 (95% confidence interval = -2.02 to -0.75 L/minute/m(2), P = 0.02) to -2.51 L/minute/m(2) (95% confidence interval = -3.36 to -1.65 L/minute/m(2), P < 0.001), and CI(L)-CI(TD) bias ranged from -0.65 (95% confidence interval = -1.29 to -0.01 L/minute/m(2), P = 0.047) to -1.48 L/minute/m(2) (95% confidence interval = -2.37 to -0.60 L/minute/m(2), P < 0.01). For both APCOs, bias to CI(TD) was correlated with the systemic vascular resistance index, with a stronger dependence for FloTrac-Vigileo. The capability of the APCOs for tracking changes in CI(TD) was assessed with a 4-quadrant plot for directional changes and with receiver operating characteristic curves for specificity and sensitivity. The performance of both APCOs was poor in detecting increases and fair in detecting decreases in CI(TD). In conclusion, the calibrated and uncalibrated APCOs perform differently during OLT. Although the calibrated APCO is less influenced by changes in the systemic vascular resistance, neither device can be used interchangeably with thermodilution to monitor cardiac output during liver transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Induced mild hypothermia after cardiac arrest interferes with clinical assessment of the cardiovascular status of patients. In this situation, non-invasive cardiac output measurement could be useful. Unfortunately, arterial pulse contour is altered by temperature, and the performance of devices using arterial blood pressure contour analysis to derive cardiac output may be insufficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. Methods A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. Results The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). Conclusions Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Failing cerebral blood flow (CBF) autoregulation may contribute to cerebral damage after traumatic brain injury (TBI). The purpose of this study was to describe the time course of CO(2)-dependent vasoreactivity, measured as CBF velocity in response to hyperventilation (vasomotor reactivity [VMR] index). We included 13 patients who had had severe TBI, 8 of whom received norepinephrine (NE) based on clinical indication. In these patients, measurements were also performed after dobutamine administration, with a goal of increasing cardiac output by 30%. Blood flow velocity was measured with transcranial Doppler ultrasound in both hemispheres. All patients except one had an abnormal VMR index in at least one hemisphere within the first 24 h after TBI. In those patients who did not receive catecholamines, mean VMR index recovered within the first 48 to 72 h. In contrast, in patients who received NE within the first 48 h period, VMR index did not recover on the second day. Cardiac output and mean CBF velocity increased significantly during dobutamine administration, but VMR index did not change significantly. In conclusion, CO(2) vasomotor reactivity was abnormal in the first 24 h after TBI in most of the patients, but recovered within 48 h in those patients who did not receive NE, in contrast to those eventually receiving the drug. Addition of dobutamine to NE had variable but overall insignificant effects on CO(2) vasomotor reactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fetal echocardiography was initially used to diagnose structural heart disease, but recent interest has focused on functional assessment. Effects of extracardiac conditions on the cardiac function such as volume overload (in the recipient in twin-twin transfusion syndrome), a hyperdynamic circulation (arterio-venous malformation), cardiac compression (diaphragmatic hernia, lung tumours) and increased placental resistance (intrauterine growth restriction and placental insufficiency) can be studied by ultrasound and may guide decisions for intervention or delivery. A variety of functional tests can be used, but there is no single clinical standard. For some specific conditions, however, certain tests have shown diagnostic value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In multiple sclerosis (MS), fatigue is a common and often disabling symptom. It has multiple causes with central motor fatigue playing an important role.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tajikistan is judged to be highly vulnerable to risk, including food insecurity risks and climate change risks. By some vulnerability measures it is the most vulnerable among all 28 countries in the World Bank’s Europe and Central Asia Region – ECA (World Bank 2009). The rural population, with its relatively high incidence of poverty, is particularly vulnerable. The Pilot Program for Climate Resilience (PPCR) in Tajikistan (2011) provided an opportunity to conduct a farm-level survey with the objective of assessing various dimensions of rural population’s vulnerability to risk and their perception of constraints to farming operations and livelihoods. The survey should be accordingly referred to as the 2011 PPCR survey. The rural population in Tajikistan is highly agrarian, with about 50% of family income deriving from agriculture (see Figure 4.1; also LSMS 2007 – own calculations). Tajikistan’s agriculture basically consists of two groups of producers: small household plots – the successors of Soviet “private agriculture” – and dehkan (or “peasant”) farms – new family farming structures that began to be created under relevant legislation passed after 1992 (Lerman and Sedik, 2008). The household plots manage 20% of arable land and produce 65% of gross agricultural output (GAO). Dehkan farms manage 65% of arable land and produce close to 30% of GAO. The remaining 15% of arable land is held in agricultural enterprises – the rapidly shrinking sector of corporate farms that succeeded the Soviet kolkhozes and sovkhozes and today produces less than 10% of GAO (TajStat 2011) The survey conducted in May 2011 focused on dehkan farms, as budgetary constraints precluded the inclusion of household plots. A total of 142 dehkan farms were surveyed in face-to-face interviews. They were sampled from 17 districts across all four regions – Sughd, Khatlon, RRP, and GBAO. The districts were selected so as to represent different agro-climatic zones, different vulnerability zones (based on the World Bank (2011) vulnerability assessment), and different food-insecurity zones (based on WFP/IPC assessments). Within each district, 3-4 jamoats were chosen at random and 2-3 farms were selected in each jamoat from lists provided by jamoat administration so as to maximize the variability by farm characteristics. The sample design by region/district is presented in Table A, which also shows the agro-climatic zone and the food security phase for each district. The sample districts are superimposed on a map of food security phases based on IPC April 2011.