5 resultados para Graft protection
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The endothelium, as an organ at the interface between the intra- and extravascular space, actively participates in maintaining an anti-inflammatory and anti-coagulant environment under physiological conditions. Severe humoral as well as cellular rejection responses, which accompany cross-species transplantation of vascularized organs as well as ischemia/reperfusion injury, primarily target the endothelium and disrupt this delicate balance. Activation of pro-inflammatory and pro-coagulant pathways often lead to irreversible injury not only of the endothelial layer but also of the entire graft, with ensuing rejection. This review focuses on strategies targeted at protecting the endothelium from such damaging effects, ranging from genetic manipulation of the donor organ to soluble, as well as membrane-targeted, protective strategies.
Resumo:
BACKGROUND: Optimal allograft protection is essential in lung transplantation to reduce postoperative organ dysfunction. Although intravenous prostanoids are routinely used to ameliorate reperfusion injury, the latest evidence suggests a similar efficacy of inhaled prostacyclin. Therefore, we compared donor lung-pretreatment using inhaled lioprost (Ventavis) with the commonly used intravenous technique. METHODS: Five pig lungs were each preserved with Perfadex and stored for 27 hours without (group 1) or with (group-2, 100 prior aerosolized of iloprost were (group 3) or iloprost (IV). Following left lung transplantation, hemodynamics, Po(2)/F(i)o(2), compliance, and wet-to-dry ratio were monitored for 6 hours and compared to sham controls using ANOVA analysis with repeated measures. RESULTS: The mortality was 100% in group 3. All other animals survived (P < .001). Dynamic compliance and PVR were superior in the endobronchially pretreated iloprost group as compared with untreated organs (P < .05), whereas oxygenation was comparable overall W/D-ratio revealed significantly lower lung water in group 2 (P = .027) compared with group 3. CONCLUSION: Preischemic alveolar deposition of iloprost is superior to IV pretreatment as reflected by significantly improved allograft function. This strategy offers technique to optimize pulmonary preservation.
Resumo:
RATIONALE: Pulmonary complications of hematopoietic stem cell transplantation include infections and graft-versus-host diseases, such as idiopathic pneumonia syndrome (IPS). Conflicting data exist regarding the role of the interferon (IFN)-gamma-producing Th1 CD4(+) T-cell subset and IL-17A in IPS. OBJECTIVES: To determine the role of IFN-gamma and IL-17A in the establishment of pulmonary graft-versus-host disease. METHODS: A semiallogeneic murine model based on C57BL/6 x BALB/c as recipients with transplantation of BALB/c RAG2(-/-) bone marrow and transfer of different genetic knockout T cells (T-bet(-/-), IFN-gamma(-/-), IFN-gammaR(-/-)) on a BALB/c background. Lung tissue was examined for parenchymal changes and infiltrating cells by histology and fluorescence-activated cell sorter analysis. MEASUREMENTS AND MAIN RESULTS: After transfer of semiallogeneic bone marrow together with donor CD4(+) T cells lacking IFN-gamma or T-bet-a T-box transcription factor controlling Th1 commitment-we found severe inflammation in the lungs, but no enhancement in other organs. In contrast, wild-type donor CD4(+) T cells mediated minimal inflammation only, and donor CD8(+) T cells were not required for IPS development. Mechanistically, the absence of IFN-gamma or IFN-gamma signaling in pulmonary parenchymal cells promoted expansion of IL-17A-producing CD4(+) T cells and local IL-17A release. In vivo depletion of IL-17A reduced disease severity. CONCLUSIONS: One mechanism of IFN-gamma protection against IPS is negative regulation of the expansion of pathogenic IL-17A-producing CD4(+) T cells through interaction with the IFN-gamma receptor on the pulmonary parenchymal cell population.
Resumo:
We showed recently that low molecular weight dextran sulfate (DXS) acts as an endothelial cell (EC) protectant and prevents human complement- and NK cell-mediated cytotoxicity towards porcine cells in vitro. We therefore hypothesized that DXS, combined with cyclosporine A (CyA), could prevent acute vascular rejection (AVR) in the hamster-to-rat cardiac xenotransplantation model. Untreated, CyA-only, and DXS-only treated rats rejected their grafts within 4-5 days. Of the hearts grafted into rats receiving DXS in combination with CyA, 28% survived more than 30 days. Deposition of anti-hamster antibodies and complement was detected in long-term surviving grafts. Combined with the expression of hemoxygenase 1 (HO-1) on graft EC, these results indicate that accommodation had occurred. Complement activity was normal in rat sera after DXS injection, and while systemic inhibition of the coagulation cascade was observed 1 h after DXS injection, it was absent after 24 h. Moreover, using a fluorescein-labeled DXS (DXS-Fluo) injected 1 day after surgery, we observed a specific binding of DXS-Fluo to the xenograft endothelium. In conclusion, we show here that DXS + CyA induces long-term xenograft survival and we provide evidence that DXS might act as a local EC protectant also in vivo.
Resumo:
BACKGROUND Stroke is a major cause of morbidity and mortality during open-heart surgery. Up to 60% of intraoperative cerebral events are emboli induced. This randomized, controlled, multicenter trial is the first human study evaluating the safety and efficacy of a novel aortic cannula producing simultaneous forward flow and backward suction for extracting solid and gaseous emboli from the ascending aorta and aortic arch upon their intraoperative release. METHODS Sixty-six patients (25 females; 68±10 years) undergoing elective aortic valve replacement surgery, with or without coronary artery bypass graft surgery, were randomized to the use of the CardioGard (CardioGard Medical, Or-Yehuda, Israel) Emboli Protection cannula ("treatment") or a standard ("control") aortic cannula. The primary endpoint was the volume of new brain lesions measured by diffusion-weighted magnetic resonance imaging (DW-MRI), performed preoperatively and postoperatively. Device safety was investigated by comparisons of complications rate, namely neurologic events, stroke, renal insufficiency and death. RESULTS Of 66 patients (34 in the treatment group), 51 completed the presurgery and postsurgery MRI (27 in the treatment group). The volume of new brain lesion for the treatment group was (mean±standard error of the mean) 44.00±64.00 versus 126.56±28.74 mm3 in the control group (p=0.004). Of the treatment group, 41% demonstrated new postoperative lesions versus 66% in the control group (p=0.03). The complication rate was comparable in both groups. CONCLUSIONS The CardioGard cannula is safe and efficient in use during open-heart surgery. Efficacy was demonstrated by the removal of a substantial amount of emboli, a significant reduction in the volume of new brain lesions, and the percentage of patients experiencing new brain lesions.