24 resultados para Glass-infiltrated alumina-based ceramic

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To assess the 5-year survival of metal-ceramic and all-ceramic tooth-supported single crowns (SCs) and to describe the incidence of biological, technical and esthetic complications. METHODS Medline (PubMed), Embase, Cochrane Central Register of Controlled Trials (CENTRAL) searches (2006-2013) were performed for clinical studies focusing on tooth-supported fixed dental prostheses (FDPs) with a mean follow-up of at least 3 years. This was complimented by an additional hand search and the inclusion of 34 studies from a previous systematic review [1,2]. Survival and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS Sixty-seven studies reporting on 4663 metal-ceramic and 9434 all-ceramic SCs fulfilled the inclusion criteria. Seventeen studies reported on metal-ceramic crowns, and 54 studies reported on all-ceramic crowns. Meta-analysis of the included studies indicated an estimated survival rate of metal-ceramic SCs of 94.7% (95% CI: 94.1-96.9%) after 5 years. This was similar to the estimated 5-year survival rate of leucit or lithium-disilicate reinforced glass ceramic SCs (96.6%; 95% CI: 94.9-96.7%), of glass infiltrated alumina SCs (94.6%; 95% CI: 92.7-96%) and densely sintered alumina and zirconia SCs (96%; 95% CI: 93.8-97.5%; 92.1%; 95% CI: 82.8-95.6%). In contrast, the 5-year survival rates of feldspathic/silica-based ceramic crowns were lower (p<0.001). When the outcomes in anterior and posterior regions were compared feldspathic/silica-based ceramic and zirconia crowns exhibited significantly lower survival rates in the posterior region (p<0.0001), the other crown types performed similarly. Densely sintered zirconia SCs were more frequently lost due to veneering ceramic fractures than metal-ceramic SCs (p<0.001), and had significantly more loss of retention (p<0.001). In total higher 5 year rates of framework fracture were reported for the all-ceramic SCs than for metal-ceramic SCs. CONCLUSIONS Survival rates of most types of all-ceramic SCs were similar to those reported for metal-ceramic SCs, both in anterior and posterior regions. Weaker feldspathic/silica-based ceramics should be limited to applications in the anterior region. Zirconia-based SCs should not be considered as primary option due to their high incidence of technical problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To determine the best-performing combination of three core buildup materials and three bonding materials based on their bond strength to ceramic blocks in vitro. MATERIALS AND METHODS The materials used for core buildup were a composite (Tetric EvoCeram), a compomer (Compoglass F), and a glass-ionomer cement (Ketac Fil Plus), and for bonding, a three-step etch-and-rinse adhesive (Syntac), a two-step etch-and-rinse adhesive (ExciTE), and a single-step system (RelyX Unicem). Bond strength to ceramic blocks was determined by shear bond strength testing. Fracture behavior was evaluated by scanning electron microscopy. RESULTS The highest adhesive values between buildup and ceramic were obtained using the materials Compoglass F and Syntac, followed by Compoglass F and ExciTE. Among the two other core buildups, Tetric EvoCeram performed better than Ketac Fil Plus, which was independent of the bonding materials. Adhesive fractures were characteristically observed with Syntac and ExciTE, and cohesive fractures were characteristically observed with RelyX Unicem. CONCLUSION These data show that compomers bonded with a multistep adhesive system achieved statistically significantly higher shear bond strength than composites and glass-ionomer cements. Within the limitations inherent to this in vitro study, the use of compomers for core buildup can be recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To assess the 5-year survival of metal-ceramic and all-ceramic tooth-supported fixed dental prostheses (FDPs) and to describe the incidence of biological, technical and esthetic complications. METHODS Medline (PubMed), Embase and Cochrane Central Register of Controlled Trials (CENTRAL) searches (2006-2013) were performed for clinical studies focusing on tooth-supported FDPs with a mean follow-up of at least 3 years. This was complemented by an additional hand search and the inclusion of 10 studies from a previous systematic review [1]. Survival and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS Forty studies reporting on 1796 metal-ceramic and 1110 all-ceramic FDPs fulfilled the inclusion criteria. Meta-analysis of the included studies indicated an estimated 5-year survival rate of metal-ceramic FDPs of 94.4% (95% CI: 91.2-96.5%). The estimated survival rate of reinforced glass ceramic FDPs was 89.1% (95% CI: 80.4-94.0%), the survival rate of glass-infiltrated alumina FDPs was 86.2% (95% CI: 69.3-94.2%) and the survival rate of densely sintered zirconia FDPs was 90.4% (95% CI: 84.8-94.0%) in 5 years of function. Even though the survival rate of all-ceramic FDPs was lower than for metal-ceramic FDPs, the differences did not reach statistical significance except for the glass-infiltrated alumina FDPs (p=0.05). A significantly higher incidence of caries in abutment teeth was observed for densely sintered zirconia FDPs compared to metal-ceramic FDPs. Significantly more framework fractures were reported for reinforced glass ceramic FDPs (8.0%) and glass-infiltrated alumina FDPs (12.9%) compared to metal-ceramic FDPs (0.6%) and densely sintered zirconia FDPs (1.9%) in 5 years in function. However, the incidence of ceramic fractures and loss of retention was significantly (p=0.018 and 0.028 respectively) higher for densely sintered zirconia FDPs compared to all other types of FDPs. CONCLUSIONS Survival rates of all types of all-ceramic FDPs were lower than those reported for metal-ceramic FDPs. The incidence of framework fractures was significantly higher for reinforced glass ceramic FDPs and infiltrated glass ceramic FDPs, and the incidence for ceramic fractures and loss of retention was significantly higher for densely sintered zirconia FDPs compared to metal-ceramic FDPs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of MWCNT introduction in a polycarbosilane based ceramic on its electrical properties is presented. The electrical conductivity of two MWCNT powders was measured under dynamic compaction up to 20 MPa when it reached 3–5 S/cm. The compaction behavior was also analyzed and modeled. A composite was then realized using allylhydridopolycarbosilane SMP10® and divinylbenzene as matrix. Intact 10 mm MWCNT-SiC ceramic discs samples with 2 wt.% filler load were produced pressure-less via liquid route despite the linear shrinkage of about 30%. Nanotubes microstructure and distribution in the matrix were confirmed after pyrolysis with TEM and SEM analysis. Anyhow similar electrical conductivity values after pyrolysis between the loaded and unloaded samples were measured. The microstructure analysis via XRD and TEM revealed that the percolative carbon network formed through the use of divinylbenzene improves the electric conductivity more than that of MWCNT addition and also simplifies the whole process.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: The aim of the study was to evaluate the biological effects of water eluents from polycarbonate based esthetic orthodontic brackets. METHODS: The composite polycarbonate brackets tested were Silkon Plus (SL, fiber-glass-reinforced), Elan ME (EL, ceramic particle-reinforced) and Elegance (EG, fiber-glass-reinforced). An unfilled polyoxymethylene bracket (Brilliant, BR) was used as control. The brackets' composition was analyzed by ATR-FTIR spectrometry. The cytotoxicity and estrogenicity of the eluents obtained after 3months storage of the brackets in water (37°C) were investigated in murine fibroblasts (NIH 3T3), breast (MCF-7) and cervical cancer (CCl-2/Hela) cell lines. RESULTS: SL and EG were based on aromatic-polycarbonate matrix, whereas EL consisted of an aromatic polycarbonate-polyethylene terepthalate copolymer. A significant induction of cell death and a concurrent decrease in cell proliferation was noted in the EG eluent-treated cells. Moreover, EG eluent significantly reduced the levels of the estrogen signaling associated gene pS2, specifically in MCF7 cells, suggesting that cell death induced by this material is associated with downregulation of estrogen signaling pathways. Even though oxidative stress mechanisms were equally activated by all eluents, the EG eluents induced expression of apoptosis inducing factor (AIF) and reduced Bcl-xL protein levels. SIGNIFICANCE: Some polycarbonate-based composite brackets when exposed to water release substances than activate mitochondrial apoptosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

From June 1997 to June 2003 we performed 194 total hip arthroplasties on 173 patients using alumina ceramic-on-ceramic bearings as part of a prospective United States Food and Drug Administration/Investigational Device Exemption study. The average patient age at surgery was 49.9 years. Minimum followup time was 2 years (mean 4.3 years, range 2-9 years). We evaluated survival rate, implant- and nonimplant-related complications. Clinical outcomes included the Merle d'Aubigné score. We assessed radiographs for signs of osteolysis, component loosening, and implant wear. No patients had osteolysis and there were no hip dislocations. Implant survivorship for all hips with aseptic revision of any component was 96% (CI, 91-100) at 9 year; survivorship for hips without prior surgery was 99.3%, (CI, 98-100). There was a 1.7% incidence of implant-related complications. Our data help confirm two United States FDA/IDE studies on alumina ceramic-on-ceramic total hip arthroplasty that reported low aseptic revision rates and low revision rates for instability. Total hip arthroplasty using alumina ceramic-on-ceramic implants is a safe and reliable procedure in the comparably young and active patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the most intriguing phenomena in glass forming systems is the dynamic crossover (T(B)), occurring well above the glass temperature (T(g)). So far, it was estimated mainly from the linearized derivative analysis of the primary relaxation time τ(T) or viscosity η(T) experimental data, originally proposed by Stickel et al. [J. Chem. Phys. 104, 2043 (1996); J. Chem. Phys. 107, 1086 (1997)]. However, this formal procedure is based on the general validity of the Vogel-Fulcher-Tammann equation, which has been strongly questioned recently [T. Hecksher et al. Nature Phys. 4, 737 (2008); P. Lunkenheimer et al. Phys. Rev. E 81, 051504 (2010); J. C. Martinez-Garcia et al. J. Chem. Phys. 134, 024512 (2011)]. We present a qualitatively new way to identify the dynamic crossover based on the apparent enthalpy space (H(a)(') = dlnτ/d(1/T)) analysis via a new plot lnH(a)(') vs. 1∕T supported by the Savitzky-Golay filtering procedure for getting an insight into the noise-distorted high order derivatives. It is shown that depending on the ratio between the "virtual" fragility in the high temperature dynamic domain (m(high)) and the "real" fragility at T(g) (the low temperature dynamic domain, m = m(low)) glass formers can be splitted into two groups related to f < 1 and f > 1, (f = m(high)∕m(low)). The link of this phenomenon to the ratio between the apparent enthalpy and activation energy as well as the behavior of the configurational entropy is indicated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim of the investigation was to assess the effect of different surface treatments on the bond strength of veneering ceramics to zirconia. In a shear test, the influences of polishing, sandblasting, and silica-coating of the zirconia surface on bonding were assessed with five different veneering ceramics. In addition the effect of liner application was examined. With one veneering ceramic, the impact of regeneration firing of zirconia was also evaluated. Statistical analysis was performed with one-way ANOVA and post hoc Scheffé's test. Failure in every case occurred in the veneering ceramic adjacent to the interface with a thin layer of ceramic remaining on the zirconia surface, indicating that bond strength was higher than the cohesive strength of the veneering ceramic. Shear strength ranged from 23.5 +/- 3.4 MPa to 33.0 +/- 6.8 MPa without explicit correlation to the respective surface treatment. Regeneration firing significantly decreased the shear strength of both polished and sandblasted surfaces. Findings of this study revealed that bonding between veneering ceramics and zirconia might be based on chemical bonds. On this note, sandblasting was not a necessary surface pretreatment to enhance bond strength and that regeneration firing was not recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to investigate micromechanical properties of five dual-curing resin cements after different curing modes including light curing through glass ceramic materials. MATERIALS AND METHODS Vickers hardness (VH) and indentation modulus (Y HU) of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA were measured after 1 week of storage (37 °C, 100 % humidity). The resin cements were tested following self-curing or light curing with the second-generation light-emitting diode (LED) curing unit Elipar FreeLight 2 in Standard Mode (1,545 mW/cm(2)) or with the third-generation LED curing unit VALO in High Power Mode (1,869 mW/cm(2)) or in XtraPower Mode (3,505 mW/cm(2)). Light curing was performed directly or through glass ceramic discs of 1.5 or 3 mm thickness of IPS Empress CAD or IPS e.max CAD. VH and Y HU were analysed with Kruskal-Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). RESULTS RelyX Unicem 2 Automix resulted in the highest VH and Y HU followed by BeautiCem SA, BisCem, SpeedCEM, and finally Panavia F2.0. Self-curing of RelyX Unicem 2 Automix and SpeedCEM lowered VH and Y HU compared to light curing whereas self-curing of Panavia F2.0, BisCem, and BeautiCem SA led to similar or significantly higher VH and Y HU compared to light curing. Generally, direct light curing resulted in similar or lower VH and Y HU compared to light curing through 1.5-mm-thick ceramic discs. Light curing through 3-mm-thick discs of IPS e.max CAD generally reduced VH and Y HU for all resin cements except SpeedCEM, which was the least affected by light curing through ceramic discs. CONCLUSIONS The resin cements responded heterogeneously to changes in curing mode. The applied irradiances and light curing times adequately cured the resin cements even through 1.5-mm-thick ceramic discs. CLINICAL RELEVANCE When light curing resin cements through thick glass ceramic restorations, clinicians should consider to prolong the light curing times even with LED curing units providing high irradiances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives The aim of this study was to measure the degree of conversion (DC) of five dual-curing resin cements after different curing modes with a second- and a third-generation light-emitting diode (LED) curing unit. Additionally, irradiance of both light curing units was measured at increasing distances and through discs of two glass ceramics for computer-aided design/manufacturing (CAD/CAM). Materials and methods Irradiance and spectra of the Elipar FreeLight 2 (Standard Mode (SM)) and of the VALO light curing unit (High Power Mode (HPM) and Xtra Power Mode (XPM)) were measured with a MARC radiometer. Irradiance was measured at increasing distances (control) and through discs (1.5 to 6 mm thickness) of IPS Empress CAD and IPS e.max CAD. DC of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA was measured with an attenuated total reflectance–Fourier transform infrared spectrometer when self-cured (negative control) or light cured in SM for 40 s, HPM for 32 s, or XPM for 18 s. Light curing was performed directly (positive control) or through discs of either 1.5- or 3-mm thickness of IPS Empress CAD or IPS e.max CAD. DC was analysed with Kruskal–Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). Results Maximum irradiances were 1,545 mW/cm2 (SM), 2,179 mW/cm2 (HPM), and 4,156 mW/cm2 (XPM), and all irradiances decreased by >80 % through discs of 1.5 mm, ≥95 % through 3 mm, and up to >99 % through 6 mm. Generally, self-curing resulted in the lowest DC. For some cements, direct light curing did not result in higher DC compared to when light cured through ceramic discs. For other cements, light curing through ceramic discs of 3 mm generally reduced DC. Conclusions Light curing was favourable for dual-curing cements. Some cements were more susceptible to variations in curing mode than others. Clinical relevance When light curing a given cement, the higher irradiances of the third-generation LED curing unit resulted in similar DC compared to the second-generation one, though at shorter light curing times.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1944/1945 wurde in Cham-Hagendorn eine Wassermühle ausgegraben, die dank ihrer aussergewöhnlich guten Holzerhaltung seit langem einen prominenten Platz in der Forschung einnimmt. 2003 und 2004 konnte die Kantonsarchäologie Zug den Platz erneut archäologisch untersuchen. Dabei wurden nicht nur weitere Reste der Wassermühle, sondern auch Spuren älterer und jüngerer Anlagen geborgen: eine ältere und eine jüngere Schmiedewerkstatt (Horizont 1a/Horizont 3) sowie ein zweiphasiges Heiligtum (Horizonte 1a/1b). All diese Anlagen lassen sich nun in das in den neuen Grabungen erkannte stratigraphische Gerüst einhängen (s. Beil. 2). Dank der Holzerhaltung können die meisten Phasen dendrochronologisch datiert werden (s. Abb. 4.1/1a): Horizont 1a mit Schlagdaten zwischen 162(?)/173 und 200 n. Chr., Horizont 1b um 215/218 n. Chr. und Horizont 2 um 231 n. Chr. Ferner konnten in den neuen Grabungen Proben für mikromorphologische und archäobotanische Untersuchungen entnommen werden (Kap. 2.2; 3.11). In der vorliegenden Publikation werden der Befund und die Baustrukturen vorgelegt, (Kap. 2), desgleichen sämtliche stratifizierten Funde und eine umfassende Auswahl der 1944/1945 geborgenen Funde (Kap. 3). Dank anpassender Fragmente, sog. Passscherben, lassen sich diese zum Teil nachträglich in die Schichtenabfolge einbinden. Die mikromorphologischen und die archäobotanischen Untersuchungen (Kap. 2.2; 3.11) zeigen, dass der Fundplatz in römischer Zeit inmitten einer stark vom Wald und dem Fluss Lorze geprägten Landschaft lag. In unmittelbarer Nähe können weder eine Siedlung noch einzelne Wohnbauten gelegen haben. Die demnach nur gewerblich und sakral genutzten Anlagen standen an einem Bach, der vermutlich mit jenem Bach identisch ist, der noch heute das Groppenmoos entwässert und bei Cham-Hagendorn in die Lorze mündet (s. Abb. 2.4/1). Der antike Bach führte wiederholt Hochwasser ─ insgesamt sind fünf grössere Überschwemmungsphasen auszumachen (Kap. 2.2; 2.4). Wohl anlässlich eines Seehochstandes durch ein Überschwappen der Lorze in den Bach ausgelöst, müssen diese Überschwemmungen eine enorme Gewalt entwickelt haben, der die einzelnen Anlagen zum Opfer fielen. Wie die Untersuchung der Siedlungslandschaft römischer Zeit rund um den Zugersee wahrscheinlich macht (Kap. 6 mit Abb. 6.2/2), dürften die Anlagen von Cham-Hagendorn zu einer in Cham-Heiligkreuz vermuteten Villa gehören, einem von fünf grösseren Landgütern in diesem Gebiet. Hinweise auf Vorgängeranlagen fehlen, mit denen die vereinzelten Funde des 1. Jh. n. Chr. (Kap. 4.5) in Verbindung gebracht werden könnten. Diese dürften eher von einer der Überschwemmungen bachaufwärts weggerissen und nach Cham-Hagendorn eingeschwemmt worden sein. Die Nutzung des Fundplatzes (Horizont 1a; s. Beil. 6) setzte um 170 n. Chr. mit einer Schmiedewerkstatt ein (Kap. 2.5.1). Der Fundanfall, insbesondere die Schmiedeschlacken (Kap. 3.9) belegen, dass hier nur hin und wieder Geräte hergestellt und repariert wurden (Kap. 5.2). Diese Werkstatt war vermutlich schon aufgelassen und dem Verfall preisgegeben, als man 200 n. Chr. (Kap. 4.2.4) auf einer Insel zwischen dem Bach und einem Lorzearm ein Heiligtum errichtete (Kap. 5.3). Beleg für den sakralen Status dieser Insel ist in erster Linie mindestens ein eigens gepflanzter Pfirsichbaum, nachgewiesen mit Pollen, einem Holz und über 400 Pfirsichsteinen (Kap. 3.11). Die im Bach verlaufende Grenze zwischen dem sakralen Platz und der profanen Umgebung markierte man zusätzlich mit einer Pfahlreihe (Kap. 2.5.3). In diese war ein schmaler Langbau integriert (Kap. 2.5.2), der an die oft an Temenosmauern antiker Heiligtümer angebauten Portiken erinnert und wohl auch die gleiche Funktion wie diese gehabt hatte, nämlich das Aufbewahren von Weihegaben und Kultgerät (Kap. 5.3). Das reiche Fundmaterial, das sich in den Schichten der ersten Überschwemmung fand (s. Abb. 5./5), die um 205/210 n. Chr. dieses Heiligtum zerstört hatte, insbesondere die zahlreiche Keramik (Kap. 3.2.4), und die zum Teil auffallend wertvollen Kleinfunde (Kap. 3.3.3), dürften zum grössten Teil einst in diesem Langbau untergebracht gewesen sein. Ein als Glockenklöppel interpretiertes, stratifiziertes Objekt spricht dafür, dass die fünf grossen, 1944/1945 als Stapel aufgefundenen Eisenglocken vielleicht auch dem Heiligtum zuzuweisen sind (Kap. 3.4). In diesen Kontext passen zudem die überdurchschnittlich häufig kalzinierten Tierknochen (Kap. 3.10). Nach der Überschwemmung befestigte man für 215 n. Chr. (Kap. 4.2.4) das unterspülte Bachufer mit einer Uferverbauung (Kap. 2.6.1). Mit dem Bau eines weiteren, im Bach stehenden Langbaus (Kap. 2.6.2) stellte man 218 n. Chr. das Heiligtum auf der Insel in ähnlicher Form wieder her (Horizont 1b; s. Beil. 7). Von der Pfahlreihe, die wiederum die sakrale Insel von der profanen Umgebung abgrenzte, blieben indes nur wenige Pfähle erhalten. Dennoch ist der sakrale Charakter der Anlage gesichert. Ausser dem immer noch blühenden Pfirsichbaum ist es ein vor dem Langbau aufgestelltes Ensemble von mindestens 23 Terrakottafigurinen (s. Abb. 3.6/1), elf Veneres, zehn Matres, einem Jugendlichen in Kapuzenmantel und einem kindlichen Risus (Kap. 3.6; s. auch Kap. 2.6.3). In den Sedimenten der zweiten Überschwemmung, der diese Anlage um 225/230 n. Chr. zum Opfer gefallen war, fanden sich wiederum zahlreiche Keramikgefässe (Kap. 3.2.4) und zum Teil wertvolle Kleinfunde wie eine Glasperle mit Goldfolie (Kap. 3.8.2) und eine Fibel aus Silber (Kap. 3.3.3), die wohl ursprünglich im Langbau untergebracht waren (Kap. 5.3.2 mit Abb. 5/7). Weitere Funde mit sicherem oder möglichem sakralem Charakter finden sich unter den 1944/1945 geborgenen Funden (s. Abb. 5/8), etwa ein silberner Fingerring mit Merkurinschrift, ein silberner Lunula-Anhänger, eine silberne Kasserolle (Kap. 3.3.3), eine Glasflasche mit Schlangenfadenauflage (Kap. 3.8.2) und einige Bergkristalle (Kap. 3.8.4). Im Bereich der Terrakotten kamen ferner mehrere Münzen (Kap. 3.7) zum Vorschein, die vielleicht dort niedergelegt worden waren. Nach der zweiten Überschwemmung errichtete man um 231 n. Chr. am Bach eine Wassermühle (Horizont 2; Kap. 2.7; Beil. 8; Abb. 2.7/49). Ob das Heiligtum auf der Insel wieder aufgebaut oder aufgelassen wurde, muss mangels Hinweisen offen bleiben. Für den abgehobenen Zuflusskanal der Wassermühle verwendete man mehrere stehen gebliebene Pfähle der vorangegangenen Anlagen der Horizonte 1a und 1b. Obwohl die Wassermühle den 28 jährlichen Überschwemmungshorizonten (Kap. 2.2) und den Funden (Kap. 4.3.2; 4.4.4; 45) zufolge nur bis um 260 n. Chr., während gut einer Generation, bestand, musste sie mindestens zweimal erneuert werden – nachgewiesen sind drei Wasserräder, drei Mühlsteinpaare und vermutlich drei Podeste, auf denen jeweils das Mahlwerk ruhte. Grund für diese Umbauten war wohl der weiche, instabile Untergrund, der zu Verschiebungen geführt hatte, so dass das Zusammenspiel von Wellbaum bzw. Sternnabe und Übersetzungsrad nicht mehr funktionierte und das ganze System zerbrach. Die Analyse von Pollen aus dem Gehhorizont hat als Mahlgut Getreide vom Weizentyp nachgewiesen (Kap. 3.11.4). Das Abzeichen eines Benefiziariers (Kap. 3.3.2 mit Abb. 3.3/23,B71) könnte dafür sprechen, dass das verarbeitete Getreide zumindest zum Teil für das römische Militär bestimmt war (s. auch Kap. 6.2.3). Ein im Horizont 2 gefundener Schreibgriffel und weitere stili sowie eine Waage für das Wägen bis zu 35-40 kg schweren Waren aus dem Fundbestand von 1944/1945 könnten davon zeugen, dass das Getreide zu wägen und zu registrieren war (Kap. 3.4.2). Kurz nach 260 n. Chr. fiel die Wassermühle einem weiteren Hochwasser zum Opfer. Für den folgenden Horizont 3 (Beil. 9) brachte man einen Kiesboden ein und errichtete ein kleines Gebäude (Kap. 2.8). Hier war wohl wiederum eine Schmiede untergebracht, wie die zahlreichen Kalottenschlacken belegen (Kap. 3.9), die im Umfeld der kleinen Baus zum Vorschein kamen. Aufgrund der Funde (Kap. 4.4.4; 4.5) kann diese Werkstatt nur kurze Zeit bestanden haben, höchstens bis um 270 n. Chr., bevor sie einem weiteren Hochwasser zum Opfer fiel. Von der jüngsten Anlage, die wohl noch in römische Zeit datiert (Horizont 4; Beil. 10), war lediglich eine Konstruktion aus grossen Steinplatten zu fassen (Kap. 2.9.1). Wozu sie diente, muss offen bleiben. Auch der geringe Fundanfall spricht dafür, dass die Nutzung des Platzes, zumindest für die römische Zeit, allmählich ein Ende fand (Kap. 4.5). Zu den jüngsten Strukturen gehören mehrere Gruben (Kap. 2.9.2), die vielleicht der Lehmentnahme dienten. Mangels Funden bleibt ihre Datierung indes ungewiss. Insbesondere wissen wir nicht, ob sie noch in römische Zeit datieren oder jünger sind. Spätestens mit der fünften Überschwemmung, die zur endgültigen Verlandung führte und wohl schon in die frühe Neuzeit zu setzen ist, wurde der Platz aufgelassen und erst mit dem Bau der bestehenden Fensterfabrik Baumgartner wieder besetzt.