7 resultados para GLASS-PH-ELECTRODE
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
In the United States, rumenocentesis has been recommended especially for early diagnosis of subacute rumen acidosis (SARA). The objective of the current study was to evaluate health risks due to the technique ofrumenocentesis and to measure pH in ruminal juice using a commercial indicator paper (Pehanon) and a pH electrode (reference method). After 11 dairy cows underwent rumenocentesis, the clinical status of those animals was evaluated daily, and cows were slaughtered as well as pathologically--anatomically examined on day 7. During the observation period, the following pathological clinical signs were evident: forced inspiration (3 cows), transient episode of hyperthermia (2 cows), increased tension of the abdominal wall (8 cows) and positive foreign body tests (3 cows). One cow had to be culled on day 7 because of severe generalised septic peritonitis spreading from the site of rumenocentesis. At slaughter, hematoma formation in the area of the puncture site was found in 9 out of 10 cows. It was concluded that the severe complications encountered with this technique do not legitimate rumenocentesis as a routine procedure for collection of rumen juice samples in cows under Swiss conditions. The correlation between the pH reference method and the commercial indicator paper was the high (r = 0.926).
Resumo:
Reactive transport modelling was used to simulate solute transport, thermodynamic reactions, ion exchange and biodegradation in the Porewater Chemistry (PC) experiment at the Mont Terri Rock Laboratory. Simulations show that the most important chemical processes controlling the fluid composition within the borehole and the surrounding formation during the experiment are ion exchange, biodegradation and dissolution/precipitation reactions involving pyrite and carbonate minerals. In contrast, thermodynamic mineral dissolution/precipitation reactions involving alumo-silicate minerals have little impact on the fluid composition on the time-scale of the experiment. With the accurate description of the initial chemical condition in the formation in combination with kinetic formulations describing the different stages of bacterial activities, it has been possible to reproduce the evolution of important system parameters, such as the pH, redox potential, total organic C. dissolved inorganic C and SO(4) concentration. Leaching of glycerol from the pH-electrode may be the primary source of organic material that initiated bacterial growth, which caused the chemical perturbation in the borehole. Results from these simulations are consistent with data from the over-coring and demonstrate that the Opalinus Clay has a high buffering capacity in terms of chemical perturbations caused by bacterial activity. This buffering capacity can be attributed to the carbonate system as well as to the reactivity of clay surfaces.
Resumo:
OBJECTIVE: The capability of drinks and foods to resist pH changes brought about by salivary buffering may play an important role in the dental erosion process in children. The aim of the present study was to test fruit yogurt, a popular snack for children, and the degrees of saturation (pK-pl) with respect to hydroxyapatite and fluorapatite to determine their erosive potential. METHOD AND MATERIALS: A variety of fruit yogurt was tested. To test the pH, 8 readings were taken with a pH electrode for each yogurt. Calcium content was detected by atomic absorption spectrophotometer, phosphorus by the inductively coupled plasma method, and fluoride content by ion chromatography. The degrees of saturation of hydroxyapatite and fluorapatite were calculated by use of a computer program. Statistical analysis was performed using 2-tailed analysis of variance (P < .05) and a post hoc test (Tukey) to determine differences between groups. RESULTS: The pH of each fruit concentrate was significantly different, except for banana yogurt. Except for the phosphorus content of raspberry yogurt, the calcium and phosphorus content for each fruit concentrate were significantly different. Fluoride levels were the same for all yogurts tested, and the degrees of saturation of hydroxyapatite and fluorapatite was positive, indicating supersaturation. CONCLUSION: It could be stated that fruit yogurt has no erosive potential.
Resumo:
Twenty-four-hour multichannel intraluminal impedance and pH (MII-pH) esophageal monitoring detects both acid and nonacid gastroesophageal reflux episodes. The MII-pH catheter contains six impedance segments placed 3, 5, 7, 9, 15, and 17 cm above the lower esophageal sphincter (LES). A pH electrode at 5 cm above the LES identifies the type of reflux, i.e. acid or nonacid. Patients with acid and nonacid reflux exhibit typical and atypical symptoms often within 5 min following a reflux episode. The aim of this study is to compare the timing of symptoms after reflux episodes in patients with acid and nonacid reflux. Methods include a review of 70 MII-pH tracings (42 females, mean age 40, range 18-85 years) either on (50 points) or off (20 points) acid suppression therapy. Typical (heartburn, regurgitation) and atypical (cough) symptoms with acid or nonacid reflux episodes detected by impedance were analyzed. Symptoms were considered positive with acid reflux if there was a pH drop to <4, plus an MII detected a reflux episode and with nonacid reflux if pH remained >4 and MII detected a reflux episode. The timing of the symptom after each reflux episode was recorded. Symptom perception occurred significantly sooner after acid versus nonacid reflux (P < 0.05). Acid reflux episodes are more likely to be perceived in the first 2 min following the reflux episode. Patients with acid reflux are likely to perceive symptoms earlier, and symptoms with acid and nonacid reflux may be produced by different mechanisms.
Resumo:
PURPOSE The purpose of this study was to evaluate the bonding of glass ionomer cements (GICs) to sound and caries-affected dentin by microtensile bond strength (μTBS) and nanoleakage (NL) tests. METHODS Occlusal cavity preparations were made in 36 sound primary molars. Half of the specimens were submitted to a pH-cycling model to create simulated caries-affected dentin. Teeth were randomly restored with one of the three materials: (1) resin-modified GIC with nanoparticles (Ketac N100; KN); (2) resin-modified GIC (Vitremer; VI); and (3) high-viscosity GIC (Ketac Molar Easy Mix; KM). Specimens were tested using a microtensile test (1 mm/minute). One specimen from each tooth was immersed in ammoniacal silver nitrate for 24 hours and revealed after eight hours to assess interfacial NL. The μTBS means were analyzed by 2-way analysis of variance and Tukey's post hoc test. For NL, Kruskal-Wallis and Mann-Whitney tests were used (P<.05). RESULTS No difference was found between sound and caries-affected dentin (P>.05). KM showed the lowest GIC-dentin μTBS values, while VI and KN showed higher values. Infiltration of ammoniacal silver nitrate into the adhesive interface was not affected by sound or caries-affected dentin. CONCLUSION Caries-affected dentin does not jeopardize the bonding of glass ionomer cements to primary tooth dentin.
Resumo:
The Youngest Toba Tuff (YTT, erupted ca. 74 ka ago) is a distinctive and widespread tephra marker across south and southeast Asia. The climatic, human and environmental consequences of the YTT eruption are widely debated. Although a considerable body of geochemical data is available for this unit, there has not been a systematic study of the variability of the ash geochemistry. Intrinsic (magmatic) and extrinsic (post-depositional) chemical variations bring fundamental information regarding the petrogenesis of the magma, the distribution of the tephra and the interaction between the ash and the receiving environment. Considering the importance of the geochemistry of the YTT for stratigraphic correlations and eruptive models, it is central to the YTT debate to quantify and interpret such variations. Here we collate all published geochemical data on the YTT glass, including analyses from 68 sites described in the literature and three new samples. Two principal sources of chemical variation are investigated: (i) compositional zonation of the magma reservoir, and (ii) post-depositional alteration. Post-depositional leaching is responsible for up to ca. 11% differences in Na2O/K2O and ca. 1% differences in SiO2/Al2O3 ratios in YTT glass from marine sites. Continental tephra are 2% higher in Na2O/K2O and 3% higher in SiO2/Al2O3 respect to the marine tephra. We interpret such post-depositional glass alteration as related to seawater induced alkali migration in marine environments, or to site-specific water pH. Crystal fractionation and consequential magmatic differentiation, which produced order-of-magnitude variations in trace element concentrations reported in the literature, also produced major element differences in the YTT glass. FeO/Al2O3 ratios vary by about 50 %, which is analytically significant. These variations represent magmatic fractionation involving Fe-bearing phases. We also compared major element concentrations in YTT and Oldest Toba Tuff (OTT) ash samples, to identify potential compositional differences that could constrain the stratigraphic identity of the Morgaon ash (Western India); no differences between the OTT and YTT samples were observed.
Resumo:
A retrospective evaluation of glass ionomer cement (GIC) in middle ear surgery with emphasis on short- and long-term safety was conducted at the tertiary referral center. GIC was applied between 1995 and 2006 in 444 patients in otologic surgery. Technical aspects, safety, benefits and complications due to GIC were analysed until 2011 (follow-up 5-16 years; mean 10 years). GIC was applied in stapes surgery (228 primary, 92 revisions), cochlear implants (108) and implantable hearing aids (7), ossiculoplasty (7), for coverage of opened mastoid air cells towards the external ear canal (1) and inner ear fistula closure (1). GIC turned out to be very handy in stapes surgery for optimal prosthesis fixation at the incus (260) and on the malleus handle (60) without complications. Results suggest that GIC may diminish the danger of incus necrosis in primary stapedotomy. In cochlear implants and implantable hearing aids, GIC was used for casing alone (74), casing and electrode fixation (27) and electrode alone fixation (14). Inflammatory reactions were observed in five cases (4.3 %), mostly after trauma. Broken cement fragments appeared to promote foreign body rejection. In seven cases an incudo-stapedial gap was repaired with GIC with excellent hearing gain; in three cases (43 %) revision surgery was needed due to cement breakage. In one case, GIC was applied for a watertight coverage of opened mastoid cells, and in the other for fistula closure of the lateral semi-circular canal over cartilage, covered with bone pathé; follow-up was uneventful. Targeted use of GIC in middle ear surgery rarely poses problems. GIC cannot be used in neuro-otosurgery in contact with cerebrospinal fluid because of possible aluminium encephalopathy.