3 resultados para GIC’s
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
PURPOSE The purpose of this study was to evaluate the bonding of glass ionomer cements (GICs) to sound and caries-affected dentin by microtensile bond strength (μTBS) and nanoleakage (NL) tests. METHODS Occlusal cavity preparations were made in 36 sound primary molars. Half of the specimens were submitted to a pH-cycling model to create simulated caries-affected dentin. Teeth were randomly restored with one of the three materials: (1) resin-modified GIC with nanoparticles (Ketac N100; KN); (2) resin-modified GIC (Vitremer; VI); and (3) high-viscosity GIC (Ketac Molar Easy Mix; KM). Specimens were tested using a microtensile test (1 mm/minute). One specimen from each tooth was immersed in ammoniacal silver nitrate for 24 hours and revealed after eight hours to assess interfacial NL. The μTBS means were analyzed by 2-way analysis of variance and Tukey's post hoc test. For NL, Kruskal-Wallis and Mann-Whitney tests were used (P<.05). RESULTS No difference was found between sound and caries-affected dentin (P>.05). KM showed the lowest GIC-dentin μTBS values, while VI and KN showed higher values. Infiltration of ammoniacal silver nitrate into the adhesive interface was not affected by sound or caries-affected dentin. CONCLUSION Caries-affected dentin does not jeopardize the bonding of glass ionomer cements to primary tooth dentin.
Resumo:
BACKGROUND The purpose of the present study is to evaluate the 10-year results following treatment of intrabony defects treated with an enamel matrix protein derivative (EMD) combined with either a natural bone mineral (NBM) or β-tricalcium phosphate (β-TCP). METHODS Twenty-two patients with advanced chronic periodontitis and displaying one deep intrabony defect were randomly treated with a combination of either EMD + NBM or EMD + β-TCP. Clinical evaluations were performed at baseline and at 1 and 10 years. The following parameters were evaluated: plaque index, bleeding on probing, probing depth, gingival recession, and clinical attachment level (CAL). The primary outcome variable was CAL. RESULTS The defects treated with EMD + NBM demonstrated a mean CAL change from 8.9 ± 1.5 mm to 5.3 ± 0.9 mm (P <0.001) and to 5.8 ± 1.1 mm (P <0.001) at 1 and 10 years, respectively. The sites treated with EMD + β-TCP showed a mean CAL change from 9.1 ± 1.6 mm to 5.4 ± 1.1 mm (P <0.001) at 1 year and 6.1 ± 1.4 mm (P <0.001) at 10 years. At 10 years two defects in the EMD + NBM group had lost 2 mm, whereas two other defects had lost 1 mm of the CAL gained at 1 year. In the EMD + β-TCP group three defects had lost 2 mm, whereas two other defects had lost 1 mm of the CAL gained at 1 year. Compared with baseline, at 10 years, a CAL gain of ≥3 mm was measured in 64% (i.e., seven of 11) of the defects in the EMD + NBM group and in 82% (i.e., nine of 11) of the defects in the EMD + β-TCP group. No statistically significant differences were found between the 1- and 10-year values in either of the two groups. Between the treatment groups, no statistically significant differences in any of the investigated parameters were observed at 1 and 10 years. CONCLUSION Within their limitations, the present findings indicate that the clinical improvements obtained with regenerative surgery using EMD + NBM or EMD + β-TCP can be maintained over a period of 10 years.
Resumo:
OBJECTIVES The shear bond strength of three glass ionomer cements (GIC) to enamel and dentine was evaluated. STUDY DESIGN Sound permanent human molars (n=12) were grinded perpendicular to their axial axes, exposing smooth, flat enamel and dentine surfaces. The teeth were embedded in resin and conditioned with polyacrylic acid (25%; 10s). Twenty four specimens of each GIC: Fuji IX (FJ-GC), Ketac Molar Easymix (KM-3M ESPE) and Maxxion (MX-FGM) were prepared according to the Atraumatic Restorative Treatment (ART) (12 enamel and 12 dentine), in a bonding area of 4.91 mm² and immersed in water (37°C, 24h). The shear bond strength was tested in a universal testing machine. Non-parametric statistical tests (Friedman and post-hoc Wilcoxon Signed Ranks) were carried out (p=0.05). RESULTS The mean (±sd) of shear bond strength (MPa), on enamel and dentine, were: KM (6.4±1.4 and 7.6±1.5), FJ (5.9±1.5 and 6.0±1.9) and MX (4.2±1.5 and 4.9±1.5), respectively. There was a statistically significant difference between the GICs in both groups: enamel (p=0.004) and dentine (p=0.002). The lowest shear bond value for enamel was with MX and the highest for dentine was KM (p<0.05). CONCLUSION It is concluded that KM has the best adhesion to both enamel and dentine, followed by FJ and MX.