11 resultados para Fuzzy Modelling, Short Circuit, GMAW-P, Welding, Gas Metal Arc Welding

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract We hypothesise that inflammatory response and morphological characteristics of lung parenchyma differ after exposure to short or long multi-walled carbon nanotubes (MWCNT). Mice were subjected to a single dose of vehicle, short or long MWCNT by pharyngeal aspiration. Bronchoalveolar lavage fluid (BALF) obtained at 24 h was analysed for inflammatory reaction and lung tissue was analysed for morphological alterations using stereology. Short MWCNT had stronger potential to induce polymorphonuclear cells whereas long MWCNT increased interleukin-6 levels in BALF. Alveolar septal fibrosis was only observed with short MWCNT. Type II pneumocyte hypertrophy was only detected with long MWCNT. There was no reduction in total alveolar surface area and no sign of type II cell hyperplasia. We observed mild inflammatory and pathological responses to short and long MWCNT in the lung parenchyma depending on the size of the applied MWCNT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

(31)P MRS magnetization transfer ((31)P-MT) experiments allow the estimation of exchange rates of biochemical reactions, such as the creatine kinase equilibrium and adenosine triphosphate (ATP) synthesis. Although various (31)P-MT methods have been successfully used on isolated organs or animals, their application on humans in clinical scanners poses specific challenges. This study compared two major (31)P-MT methods on a clinical MR system using heteronuclear surface coils. Although saturation transfer (ST) is the most commonly used (31)P-MT method, sequences such as inversion transfer (IT) with short pulses might be better suited for the specific hardware and software limitations of a clinical scanner. In addition, small NMR-undetectable metabolite pools can transfer MT to NMR-visible pools during long saturation pulses, which is prevented with short pulses. (31)P-MT sequences were adapted for limited pulse length, for heteronuclear transmit-receive surface coils with inhomogeneous B1 , for the need for volume selection and for the inherently low signal-to-noise ratio (SNR) on a clinical 3-T MR system. The ST and IT sequences were applied to skeletal muscle and liver in 10 healthy volunteers. Monte-Carlo simulations were used to evaluate the behavior of the IT measurements with increasing imperfections. In skeletal muscle of the thigh, ATP synthesis resulted in forward reaction constants (k) of 0.074 ± 0.022 s(-1) (ST) and 0.137 ± 0.042 s(-1) (IT), whereas the creatine kinase reaction yielded 0.459 ± 0.089 s(-1) (IT). In the liver, ATP synthesis resulted in k = 0.267 ± 0.106 s(-1) (ST), whereas the IT experiment yielded no consistent results. ST results were close to literature values; however, the IT results were either much larger than the corresponding ST values and/or were widely scattered. To summarize, ST and IT experiments can both be implemented on a clinical body scanner with heteronuclear transmit-receive surface coils; however, ST results are much more robust against experimental imperfections than the current implementation of IT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is well known that gases adsorb on many surfaces, in particular metal surfaces. There are two main forms responsible for these effects (i) physisorption and (ii) chemisorption. Physisorption is associated with lower binding energies in the order of 1–10 kJ mol−¹, compared to chemisorption which ranges from 100 to 1000 kJ mol−¹. Furthermore, chemisorption only forms monolayers, contrasting physisorption that can form multilayer adsorption. The reverse process is called desorption and follows similar mathematical laws; however, it can be influenced by hysteresis effects. In the present experiment, we investigated the adsorption/desorption phenomena on three steel and three aluminium cylinders containing compressed air in our laboratory and under controlled conditions in a climate chamber, respectively. Our observations from completely decanting one steel and two aluminium cylinders are in agreement with the pressure dependence of physisorption for CO₂, CH₄, and H₂O. The CO₂ results for both cylinder types are in excellent agreement with the pressure dependence of a monolayer adsorption model. However, mole fraction changes due to adsorption on aluminium (< 0.05 and 0 ppm for CO₂ and H₂O) were significantly lower than on steel (< 0.41 ppm and about < 2.5 ppm, respectively). The CO₂ amount adsorbed (5.8 × 1019 CO₂ molecules) corresponds to about the fivefold monolayer adsorption, indicating that the effective surface exposed for adsorption is significantly larger than the geometric surface area. Adsorption/desorption effects were minimal for CH₄ and for CO but require further attention since they were only studied on one aluminium cylinder with a very low mole fraction. In the climate chamber, the cylinders were exposed to temperatures between −10 and +50 °C to determine the corresponding temperature coefficients of adsorption. Again, we found distinctly different values for CO₂, ranging from 0.0014 to 0.0184 ppm °C−¹ for steel cylinders and −0.0002 to −0.0003 ppm °C−¹ for aluminium cylinders. The reversed temperature dependence for aluminium cylinders points to significantly lower desorption energies than for steel cylinders and due to the small values, they might at least partly be influenced by temperature, permeation from/to sealing materials, and gas-consumption-induced pressure changes. Temperature coefficients for CH₄, CO, and H₂O adsorption were, within their error bands, insignificant. These results do indicate the need for careful selection and usage of gas cylinders for high-precision calibration purposes such as requested in trace gas applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of the present study was to examine the suitability of a short pre-stimulation (P) for 15 s followed by a latency period (L) of 30 s before cluster attachment for machine milking. In addition we tested the effect of a periodic reduction of the vacuum under the teat (VR) during the massage phase from 43 kPa to 12-15 kPa on milking characteristics and teat tissue condition. The study was carried out in 9 cows in a cross-over design. Animals were milked twice daily, and each of the 4 treatment combinations was used for six subsequent milkings (P+L vs. continuous P, and standard pulsation vs. VR, respectively). Milk flow was recorded during all experimental milkings. Longitudinal ultrasound cross sections of the teat were performed by B-mode ultrasound after the last milking of each treatment at 0, 5, and 15 min after the end of milking, respectively. None of the evaluated milking characteristics (total milk yield, main milking time, peak flow rate, average milk flow) differed between treatments. Teat measures as obtained by ultrasound cross sections showed no significant difference if individual treatments were compared at the three time points individually. However, teat wall thickness (TWT) tended to be smaller in VR vs. non-VR treatments at 5 min after milking (P=0·05). In conclusion, teat preparation consisting of a short stimulation followed by a latency period represents a similarly efficient pre-stimulation as a continuous pre-stimulation. VR seems to reduce the load on the teat tissue during milking and thus reduces the development of oedema and hence a less pronounced increase of TWT while milking characteristics are similar with or without VR.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The chiral pharmacokinetics and pharmacodynamics of ketoprofen were investigated in a placebo-controlled study in piglets after intramuscular administration of 6 mg/kg racemic ketoprofen. The absorption half-lives of both enantiomers were short, and S-ketoprofen predominated over R-ketoprofen in plasma. A kaolin-induced inflammation model was used to evaluate the anti-inflammatory, antipyretic and analgesic effects of ketoprofen. Skin temperatures increased after the kaolin injection, but the effect of ketoprofen was small. No significant antipyretic effects could be detected, but body temperatures tended to be lower in the ketoprofen-treated piglets. Mechanical nociceptive threshold testing was used to evaluate the analgesic effects. The piglets in the ketoprofen-treated group had significantly higher mechanical nociceptive thresholds compared to the piglets in the placebo group for 12-24 h following the treatment. Pharmacokinetic/pharmacodynamic modelling of the results from the mechanical nociceptive threshold testing gave a median IC(50) for S-ketoprofen of 26.7 mug/mL and an IC(50) for R-ketoprofen of 1.6 mug/mL. This indicates that R-ketoprofen is a more potent analgesic than S-ketoprofen in piglets. Estimated ED(50) for racemic ketoprofen was 2.5 mg/kg.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In addition to plasma metabolites and hormones participating as humoral signals in the control of feed intake, oxidative metabolic processes in peripheral organs also generate signals to terminate feeding. Although the degree of oxidation over longer periods is relatively constant, recent work suggests that the periprandial pattern of fuel oxidation is involved in regulating feeding behavior in the bovine. However, the association between periprandial oxidative metabolism and feed intake of dairy cows has not yet been studied. Therefore, the aim of this study was to elucidate possible associations existing between single feed intake events and whole-body net fat and net carbohydrate oxidation as well as their relation to plasma metabolite concentrations. To this end, 4 late-lactating cows equipped with jugular catheters were kept in respiratory chambers with continuous and simultaneous recording of gas exchange and feed intake. Animals were fed ad libitum (AL) for 24h and then feed restricted (RE) to 50% of the previous AL intake for a further 24h. Blood samples were collected hourly to analyze β-hydroxybutyrate (BHBA), glucose, nonesterified fatty acids (NEFA), insulin, and acylated ghrelin concentrations. Cross-correlation analysis revealed an offset ranging between 30 and 42 min between the maximum of a feed intake event and the lowest level of postprandial net fat oxidation (FOX(net)) and the maximum level of postprandial net carbohydrate oxidation (COX(net)), respectively. During the AL period, FOX(net) did not increase above -0.2g/min, whereas COX(net) did not decrease below 6g/min before the start of the next feed intake event. A strong inverse cross-correlation was obtained between COX(net) and plasma glucose concentration. Direct cross-correlations were observed between COXnet and insulin, between heat production and BHBA, between insulin and glucose, and between BHBA and ghrelin. We found no cross-correlation between FOX(net) and NEFA. During RE, FOX(net) increased with an exponential slope, exceeded the threshold of -0.2g/min as indicated by increasing plasma NEFA concentrations, and approached a maximum rate of 0.1g/min, whereas COX(net) decayed in an exponential manner, approaching a minimal COX(net) rate of about 2.5 g/min in all cows. Our novel findings suggest that, in late-lactating cows, postprandial increases in metabolic oxidative processes seem to signal suppression of feed intake, whereas preprandially an accelerated FOX(net) rate and a decelerated COX(net) rate initiate feed intake.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An accurate and coherent chronological framework is essential for the interpretation of climatic and environmental records obtained from deep polar ice cores. Until now, one common ice core age scale had been developed based on an inverse dating method (Datice), combining glaciological modelling with absolute and stratigraphic markers between 4 ice cores covering the last 50 ka (thousands of years before present) (Lemieux-Dudon et al., 2010). In this paper, together with the companion paper of Veres et al. (2013), we present an extension of this work back to 800 ka for the NGRIP, TALDICE, EDML, Vostok and EDC ice cores using an improved version of the Datice tool. The AICC2012 (Antarctic Ice Core Chronology 2012) chronology includes numerous new gas and ice stratigraphic links as well as improved evaluation of background and associated variance scenarios. This paper concentrates on the long timescales between 120–800 ka. In this framework, new measurements of δ18Oatm over Marine Isotope Stage (MIS) 11–12 on EDC and a complete δ18Oatm record of the TALDICE ice cores permit us to derive additional orbital gas age constraints. The coherency of the different orbitally deduced ages (from δ18Oatm, δO2/N2 and air content) has been verified before implementation in AICC2012. The new chronology is now independent of other archives and shows only small differences, most of the time within the original uncertainty range calculated by Datice, when compared with the previous ice core reference age scale EDC3, the Dome F chronology, or using a comparison between speleothems and methane. For instance, the largest deviation between AICC2012 and EDC3 (5.4 ka) is obtained around MIS 12. Despite significant modifications of the chronological constraints around MIS 5, now independent of speleothem records in AICC2012, the date of Termination II is very close to the EDC3 one.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Direct Simulation Monte Carlo (DSMC) is a powerful numerical method to study rarefied gas flows such as cometary comae and has been used by several authors over the past decade to study cometary outflow. However, the investigation of the parameter space in simulations can be time consuming since 3D DSMC is computationally highly intensive. For the target of ESA's Rosetta mission, comet 67P/Churyumov-Gerasimenko, we have identified to what extent modification of several parameters influence the 3D flow and gas temperature fields and have attempted to establish the reliability of inferences about the initial conditions from in situ and remote sensing measurements. A large number of DSMC runs have been completed with varying input parameters. In this work, we present the simulation results and conclude on the sensitivity of solutions to certain inputs. It is found that among cases of water outgassing, the surface production rate distribution is the most influential variable to the flow field.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE High altitude-related hypoxia induces pulmonary vasoconstriction. In Fontan patients without a contractile subpulmonary ventricle, an increase in pulmonary artery pressure is expected to decrease circulatory output and reduce exercise capacity. This study investigates the direct effects of short-term high altitude exposure on pulmonary blood flow (PBF) and exercise capacity in Fontan patients. METHODS 16 adult Fontan patients (mean age 28±7 years, 56% female) and 14 matched controls underwent cardiopulmonary exercise testing with measurement of PBF with a gas rebreathing system at 540 m (low altitude) and at 3454 m (high altitude) within 12 weeks. RESULTS PBF at rest and at exercise was higher in controls than in Fontan patients, both at low and high altitude. PBF increased twofold in Fontan patients and 2.8-fold in the control group during submaximal exercise, with no significant difference between low and high altitude (p=0.290). A reduction in peak oxygen uptake at high compared with low altitude was observed in Fontan patients (22.8±5.1 and 20.5±3.8 mL/min/kg, p<0.001) and the control group (35.0±7.4 and 29.1±6.5 mL/min/kg, p<0.001). The reduction in exercise capacity was less pronounced in Fontan patients compared with controls (9±12% vs 17±8%, p=0.005). No major adverse clinical event was observed. CONCLUSIONS Short-term high altitude exposure has no negative impact on PBF and exercise capacity in Fontan patients when compared with controls, and was clinically well tolerated. TRIAL REGISTRATION NUMBER NCT02237274: Results.