6 resultados para Full-width at half mediums
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 microm full width at half maximum (FWHM) values and 100-400 microm center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 microm FWHM and 400 microm c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 microm to less than 1 microm for a nominal FWHM value of 25 microm. The specifications of both devices, the methods used to measure these characteristics, and the results are presented.
Resumo:
We explore the feasibility of obtaining a spatially resolved picture of Ca2+Ca2+ inward currents (ICaICa) in multicellular cardiac tissue by differentiating optically recorded Ca2+Ca2+ transients that accompany propagating action potentials. Patterned growth strands of neonatal rat ventricular cardiomyocytes were stained with the Ca2+Ca2+ indicators Fluo-4 or Fluo-4FF. Preparations were stimulated at 1 Hz, and Ca2+Ca2+ transients were recorded with high spatiotemporal resolution (50 μm50 μm, 2 kHz analog bandwidth) with a photodiode array. Signals were differentiated after appropriate digital filtering. Differentiation of Ca2+Ca2+ transients resulted in optically recorded calcium currents (ORCCs) that carried the temporal and pharmacological signatures of L-type Ca2+Ca2+ inward currents: the time to peak amounted to ∼2.1 ms∼2.1 ms (Fluo-4FF) and ∼2.4 ms∼2.4 ms (Fluo-4), full-width at half-maximum was ∼8 ms∼8 ms, and ORCCs were completely suppressed by 50 μmol/L50 μmol/LCdCl2CdCl2. Also, and as reported before from patch-clamp studies, caffeine reversibly depressed the amplitude of ORCCs. The results demonstrate that the differentiation of Ca2+Ca2+ transients can be used to obtain a spatially resolved picture of the initial phase of ICaICa in cardiac tissue and to assess relative changes of activation/fast inactivation of ICaICa following pharmacological interventions.
Resumo:
In a retrospective multicentre study, the success rate and efficiency of activator treatment were analysed. All patients from two University clinics (Giessen, Germany and Berne, Switzerland) that fulfilled the selection criteria (Class II division 1 malocclusion, activator treatment, no aplasia, no extraction of permanent teeth, no syndromes, no previous orthodontic treatment except transverse maxillary expansion, full available records) were included in the study. The subject material amounted to 222 patients with a mean age of 10.6 years. Patient records, lateral head films, and dental casts were evaluated. Treatment was classified as successful if the molar relationship improved by at least half to three-fourths cusp width depending on whether or not the leeway space was used during treatment. Group comparisons were carried out using Wilcoxon two-sample and Kruskal-Wallis tests. For discrete data, chi-square analysis was used and Fisher's exact test when the sample size was small. Stepwise logistic regression was also employed. The success rate was 64 per cent in Giessen and 66 per cent in Berne. The only factor that significantly (P < 0.001) influenced treatment success was the level of co-operation. In approximately 27 per cent of the patients at both centres, the post-treatment occlusion was an 'ideal' Class I. In an additional 38 per cent of the patients, marked improvements in occlusal relationships were found. In subjects with Class II division 1 malocclusions, in which orthodontic treatment is performed by means of activators, a marked improvement of the Class II dental arch relationships can be expected in approximately 65 per cent of subjects. Activator treatment is more efficient in the late than in the early mixed dentition.
Resumo:
Beer bottles are often used in physical disputes. If the bottles break, they may give rise to sharp trauma. However, if the bottles remain intact, they may cause blunt injuries. In order to investigate whether full or empty standard half-litre beer bottles are sturdier and if the necessary breaking energy surpasses the minimum fracture-threshold of the human skull, we tested the fracture properties of such beer bottles in a drop-tower. Full bottles broke at 30 J impact energy, empty bottles at 40 J. These breaking energies surpass the minimum fracture-threshold of the human neurocranium. Beer bottles may therefore fracture the human skull and therefore serve as dangerous instruments in a physical dispute.
Resumo:
BACKGROUND AND PURPOSE Currently one of the most widely used models for the development of endovascular techniques and coiling devices for treatment of aneurysm is the elastase-induced aneurysm model in the rabbit carotid artery. Microsurgical techniques for creating an aneurysm with a venous pouch have also been established, although both techniques usually result in aneurysms less than 1 cm in diameter. We investigated whether an increase in blood flow toward the neck would produce larger aneurysms in a microsurgical venous pouch model. MATERIALS AND METHODS Microsurgical operations were performed on 11 New Zealand white rabbits. Both carotid arteries and the right jugular vein were dissected, and the right carotid artery was temporarily clipped followed by an arteriotomy. The left carotid artery was also clipped proximally, ligated distally, and sutured onto the proximal half of the arteriotomy in the right carotid artery. The venous graft was sutured onto the distal half of the arteriotomy. Digital subtraction angiography was also performed. RESULTS Angiography showed patent anastomosed vessels and aneurysms in the seven surviving rabbits. Mean aneurysm measurements among surviving rabbits with patent vessels were: 13.9 mm length, 9.3 mm width, and neck diameter 4.7 mm. The resulting mean aspect ratio was 3.35 and the mean bottleneck ratio was 3.05. CONCLUSION A large venous graft and increased blood flow toward the base of the aneurysm seem to be key factors in the creation of large venous pouch aneurysms. These large aneurysms allow testing of endovascular devices designed for large and giant aneurysms.