18 resultados para Frame and cinema
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The paper deals with the development of a general as well as integrative and holistic framework to systematize and assess vulnerability, risk and adaptation. The framework is a thinking tool meant as a heuristic that outlines key factors and different dimensions that need to be addressed when assessing vulnerability in the context of natural hazards and climate change. The approach underlines that the key factors of such a common framework are related to the exposure of a society or system to a hazard or stressor, the susceptibility of the system or community exposed, and its resilience and adaptive capacity. Additionally, it underlines the necessity to consider key factors and multiple thematic dimensions when assessing vulnerability in the context of natural and socio-natural hazards. In this regard, it shows key linkages between the different concepts used within the disaster risk management (DRM) and climate change adaptation (CCA) research. Further, it helps to illustrate the strong relationships between different concepts used in DRM and CCA. The framework is also a tool for communicating complexity and stresses the need for societal change in order to reduce risk and to promote adaptation. With regard to this, the policy relevance of the framework and first results of its application are outlined. Overall, the framework presented enhances the discussion on how to frame and link vulnerability, disaster risk, risk management and adaptation concepts.
Resumo:
Accurate placement of lesions is crucial for the effectiveness and safety of a retinal laser photocoagulation treatment. Computer assistance provides the capability for improvements to treatment accuracy and execution time. The idea is to use video frames acquired from a scanning digital ophthalmoscope (SDO) to compensate for retinal motion during laser treatment. This paper presents a method for the multimodal registration of the initial frame from an SDO retinal video sequence to a retinal composite image, which may contain a treatment plan. The retinal registration procedure comprises the following steps: 1) detection of vessel centerline points and identification of the optic disc; 2) prealignment of the video frame and the composite image based on optic disc parameters; and 3) iterative matching of the detected vessel centerline points in expanding matching regions. This registration algorithm was designed for the initialization of a real-time registration procedure that registers the subsequent video frames to the composite image. The algorithm demonstrated its capability to register various pairs of SDO video frames and composite images acquired from patients.
Resumo:
OBJECTIVE: To evaluate implant accuracy and cosmetic outcome of a new intraoperative patient-specific cranioplasty method after convexity meningioma resection. METHODS: The patient's own bone flap served as a template to mold a negative form with the use of polymethyl methacrylate (PMMA). The area of bone invasion was determined and broadly excised under white light illumination with a safety margin of at least 1 cm. The definitive replica was cast within the remaining bone flap frame and the imprint. Clinical and radiologic follow-up examinations were performed 3 months after surgery. RESULTS: Four women and two men (mean age 51.4 years ± 12.8) underwent reconstruction of bone flap defects after meningioma resection. Mean duration of intraoperative reconstruction of the partial bone flap defects was 19 minutes ± 4 (range 14-24 minutes). Implant sizes ranged from 17-35 cm(2) (mean size 22 cm(2) ± 8). Radiologic and clinical follow-up examinations revealed excellent implant alignment and favorable cosmesis (visual analogue scale for cosmesis [VASC] = 97 ± 5) in all patients. CONCLUSIONS: Patient-specific reconstruction of partial bone flap defects after convexity meningioma resection using the presented intraoperative PMMA cast method resulted in excellent bony alignment and a favorable cosmetic outcome. Relatively low costs and minimized operation time for adjustment and insertion of the cranioplasty implant justify use of this method in small bony defects as well.
Resumo:
In idiopathic portal hypertension (IPH) typical vascular lesions are present in the branches of the portal vein or in the perisinusoidal area of the liver. Similar histological alterations have been reported in the pulmonary vasculature of patients with idiopathic pulmonary artery hypertension (IPAH). As IPAH is associated with mutations of the bone morphogenetic protein receptor 2 (BMPR2) gene, the aim of this study was to investigate whether this association might also be found in patients with IPH. Twenty-three samples belonging to 21 unrelated caucasian patients with IPH followed in the hepatic haemodynamic laboratory of the Hospital Clinic in Barcelona were included in the study. All patients were studied for the entire open reading frame and splice site of the BMPR2 gene by direct sequencing and multiple ligation probe amplification (MLPA) in order to detect large deletions/duplications. None of the 23 patients had pulmonary artery hypertension. Four patients presented one single nucleotide polymorphism (SNP) in intron 5, four patients had a SNP in exon 12 and a SNP in exon 1 was found in two cases. Two patients had both intron 5 and exon 12 polymorphisms. All SNPs were previously described. Except for these three SNPs, neither mutations nor rearrangements have been identified in the BMPR2 gene in this population. We did not detect mutations or rearrangements in the coding region of the BMPR2 gene in our patients with IPH. These findings suggest that, in contrast to IPAH, mutations in BMPR2 are not involved in the pathogenesis of IPH.
Resumo:
BACKGROUND ; AIMS: Pancreatic and bile duct carcinomas represent highly aggressive malignancies that evolve from secretin receptor-rich ductular cells. With premessenger RNA splicing abnormalities common in cancer, we evaluated whether an abnormal secretin receptor spliceoform were present, characterized it, and developed a serum assay for it. METHODS: Cancer cell lines and healthy and neoplastic tissue were studied by nested reverse-transcription polymerase chain reaction and sequencing. A promising spliceoform was isolated and characterized, and monoclonal antibodies were raised to 2 distinct regions. A dual antibody enzyme-linked immunosorbent assay was developed and applied to blinded serum samples from 26 patients with pancreatic carcinoma, 10 patients with chronic pancreatitis, and 14 controls. RESULTS: Each of 9 pancreatic cancer specimens and no normal tissue expressed a secretin receptor variant with exons 3 and 4 deleted. This encoded a 111-residue peptide with its first 43 residues identical to wild-type receptor, but, subsequent to a shift in coding frame and early truncation, the next 68 residues were unique in the transcriptome/proteome. This nonfunctional soluble protein did not bind or signal in response to secretin and was secreted from transfected MiaPaCa-2 cells. Elevated serum levels of this variant were present in 69% of pancreatic cancer patients, 60% of chronic pancreatitis patients, and 1 of 14 controls. CONCLUSIONS: We identified a novel abnormal spliceoform of the secretin receptor in pancreatic and bile duct cancers and developed a dual antibody sandwich enzyme-linked immunosorbent assay to measure it in the circulation. Initial application of this assay in patients with pancreatic cancer and chronic pancreatitis was promising, but additional validation will be required to evaluate its clinical utility.
Resumo:
INTRODUCTION: Recent advances in medical imaging have brought post-mortem minimally invasive computed tomography (CT) guided percutaneous biopsy to public attention. AIMS: The goal of the following study was to facilitate and automate post-mortem biopsy, to suppress radiation exposure to the investigator, as may occur when tissue sampling under computer tomographic guidance, and to minimize the number of needle insertion attempts for each target for a single puncture. METHODS AND MATERIALS: Clinically approved and post-mortem tested ACN-III biopsy core needles (14 gauge x 160 mm) with an automatic pistol device (Bard Magnum, Medical Device Technologies, Denmark) were used for probe sampling. The needles were navigated in gelatine/peas phantom, ex vivo porcine model and subsequently in two human bodies using a navigation system (MEM centre/ISTB Medical Application Framework, Marvin, Bern, Switzerland) with guidance frame and a CT (Emotion 6, Siemens, Germany). RESULTS: Biopsy of all peas could be performed within a single attempt. The average distance between the inserted needle tip and the pea centre was 1.4mm (n=10; SD 0.065 mm; range 0-2.3 mm). The targets in the porcine liver were also accurately punctured. The average of the distance between the needle tip and the target was 0.5 mm (range 0-1 mm). Biopsies of brain, heart, lung, liver, pancreas, spleen, and kidney were performed on human corpses. For each target the biopsy needle was only inserted once. The examination of one body with sampling of tissue probes at the above-mentioned locations took approximately 45 min. CONCLUSIONS: Post-mortem navigated biopsy can reliably provide tissue samples from different body locations. Since the continuous update of positional data of the body and the biopsy needle is performed using optical tracking, no control CT images verifying the positional data are necessary and no radiation exposure to the investigator need be taken into account. Furthermore, the number of needle insertions for each target can be minimized to a single one with the ex vivo proven adequate accuracy and, in contrast to conventional CT guided biopsy, the insertion angle may be oblique. Navigation for minimally invasive tissue sampling is a useful addition to post-mortem CT guided biopsy.
Resumo:
OBJECTIVE: In search of an optimal compression therapy for venous leg ulcers, a systematic review and meta-analysis was performed of randomized controlled trials (RCT) comparing compression systems based on stockings (MCS) with divers bandages. METHODS: RCT were retrieved from six sources and reviewed independently. The primary endpoint, completion of healing within a defined time frame, and the secondary endpoints, time to healing, and pain were entered into a meta-analysis using the tools of the Cochrane Collaboration. Additional subjective endpoints were summarized. RESULTS: Eight RCT (published 1985-2008) fulfilled the predefined criteria. Data presentation was adequate and showed moderate heterogeneity. The studies included 692 patients (21-178/study, mean age 61 years, 56% women). Analyzed were 688 ulcerated legs, present for 1 week to 9 years, sizing 1 to 210 cm(2). The observation period ranged from 12 to 78 weeks. Patient and ulcer characteristics were evenly distributed in three studies, favored the stocking groups in four, and the bandage group in one. Data on the pressure exerted by stockings and bandages were reported in seven and two studies, amounting to 31-56 and 27-49 mm Hg, respectively. The proportion of ulcers healed was greater with stockings than with bandages (62.7% vs 46.6%; P < .00001). The average time to healing (seven studies, 535 patients) was 3 weeks shorter with stockings (P = .0002). In no study performed bandages better than MCS. Pain was assessed in three studies (219 patients) revealing an important advantage of stockings (P < .0001). Other subjective parameters and issues of nursing revealed an advantage of MCS as well. CONCLUSIONS: Leg compression with stockings is clearly better than compression with bandages, has a positive impact on pain, and is easier to use.
Resumo:
Identifying a human body stimulus involves mentally rotating an embodied spatial representation of one's body (motoric embodiment) and projecting it onto the stimulus (spatial embodiment). Interactions between these two processes (spatial and motoric embodiment) may thus reveal cues about the underlying reference frames. The allocentric visual reference frame, and hence the perceived orientation of the body relative to gravity, was modulated using the York Tumbling Room, a fully furnished cubic room with strong directional cues that can be rotated around a participant's roll axis. Sixteen participants were seated upright (relative to gravity) in the Tumbling Room and made judgments about body and hand stimuli that were presented in the frontal plane at orientations of 0°, 90°, 180° (upside down), or 270° relative to them. Body stimuli have an intrinsic visual polarity relative to the environment whereas hands do not. Simultaneously the room was oriented 0°, 90°, 180° (upside down), or 270° relative to gravity resulting in sixteen combinations of orientations. Body stimuli were more accurately identified when room and body stimuli were aligned. However, such congruency did not facilitate identifying hand stimuli. We conclude that static allocentric visual cues can affect embodiment and hence performance in an egocentric mental transformation task. Reaction times to identify either hands or bodies showed no dependence on room orientation.
Resumo:
Biofuel production, while highly contested, is supported by a number of policies worldwide. Ethiopia was among the first sub-Saharan countries to devise a biofuel policy strategy to guide the associated demand toward sustainable development. In this paper, I discuss Ethiopia’s biofuel policy from an interpretative research position using a frames approach and argue that useful insights can be obtained by paying more attention to national contexts and values represented in the debates on whether biofuel production can or will contribute to sustainable development. To this end, I was able to distinguish three major frames used in the Ethiopian debate on biofuels: an environmental rehabilitation frame, a green revolution frame and a legitimacy frame. The article concludes that actors advocating for frames related to social and human issues have difficulties entering the debate and forming alliances, and that those voices need to be included in order for Ethiopia to develop a sustainable biofuel sector.
Resumo:
Currently, the contributions of Starlette, Stella, and AJISAI are not taken into account when defining the International Terrestrial Reference Frame (ITRF), despite the large amount of data collected in a long time-span. Consequently, the SLR-derived parameters and the SLR part of the ITRF are almost exclusively defined by LAGEOS-1 and LAGEOS-2. We investigate the potential of combining the observations to several SLR satellites with different orbital characteristics. Ten years of SLR data are homogeneously processed using the development version 5.3 of the Bernese GNSS Software. Special emphasis is put on orbit parameterization and the impact of LEO data on the estimation of the geocenter coordinates, Earth rotation parameters, Earth gravity field coefficients, and the station coordinates in one common adjustment procedure. We find that the parameters derived from the multi-satellite solutions are of better quality than those obtained in single satellite solutions or solutions based on the two LAGEOS satellites. A spectral analysis of the SLR network scale w.r.t. SLRF2008 shows that artifacts related to orbit perturbations in the LAGEOS-1/2 solutions, i.e., periods related to the draconitic years of the LAGEOS satellites, are greatly reduced in the combined solutions.
Resumo:
The contribution of Starlette, Stella, and AJI-SAI is currently neglected when defining the International Terrestrial Reference Frame, despite a long time series of precise SLR observations and a huge amount of available data. The inferior accuracy of the orbits of low orbiting geodetic satellites is the main reason for this neglect. The Analysis Centers of the International Laser Ranging Service (ILRS ACs) do, however, consider including low orbiting geodetic satellites for deriving the standard ILRS products based on LAGEOS and Etalon satellites, instead of the sparsely observed, and thus, virtually negligible Etalons. We process ten years of SLR observations to Starlette, Stella, AJISAI, and LAGEOS and we assess the impact of these Low Earth Orbiting (LEO) SLR satellites on the SLR-derived parameters. We study different orbit parameterizations, in particular different arc lengths and the impact of pseudo-stochastic pulses and dynamical orbit parameters on the quality of the solutions. We found that the repeatability of the East and North components of station coordinates, the quality of polar coordinates, and the scale estimates of the reference are improved when combining LAGEOS with low orbiting SLR satellites. In the multi-SLR solutions, the scale and the Z component of geocenter coordinates are less affected by deficiencies in solar radiation pressure modeling than in the LAGEOS-1/2 solutions, due to substantially reduced correlations between the Z geocenter coordinate and empirical orbit parameters. Eventually, we found that the standard values of Center-of-mass corrections (CoM) for geodetic LEO satellites are not valid for the currently operating SLR systems. The variations of station-dependent differential range biases reach 52 and 25 mm for AJISAI and Starlette/Stella, respectively, which is why estimating station dependent range biases or using station-dependent CoM, instead of one value for all SLR stations, is strongly recommended.This clearly indicates that the ILRS effort to produce CoM corrections for each satellite, which are site-specific and depend on the system characteristics at the time of tracking,is very important and needs to be implemented in the SLR data analysis.