26 resultados para Foreign body granulomas
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The repair of critical-sized bony defects remains a challenge in the fields of implantology, maxillofacial surgery and orthopaedics. As an alternative bone-defect filler to autologous bone grafts, deproteinized bovine bone (DBB) is highly osteoconductive and clinically now widely used. However, this product suffers from the disadvantage of not being intrinsically osteoinductive. In the present study, this property was conferred by coating DBB with a layer of calcium phosphate into which bone morphogenetic protein 2 (BMP-2) was incorporated. Granules of DBB bearing a coating-incorporated depot of BMP-2--together with the appropriate controls (DBB bearing a coating but no BMP-2; uncoated DBB bearing adsorbed BMP-2; uncoated DBB bearing no BMP-2)--were implanted subcutaneously in rats. Five weeks later, the implants were withdrawn for a histomorphometric analysis of the volume densities of (i) bone, (ii) bone marrow, (iii) foreign-body giant cells and (iv) fibrous capsular tissue. Parameters (i) and (ii) were highest, whilst parameters (iii) and (iv) were lowest in association with DBB bearing a coating-incorporated depot of BMP-2. Hence, this mode of functionalization not only confers DBB with the property of osteoinductivity but also improves its biocompatibility--thus dually enhancing its clinical potential in the repair of bony defects.
Resumo:
A 13-month-old, neutered female domestic shorthaired cat was evaluated for vomiting, anorexia, and lethargy. The cat was icteric and hyperbilirubinemic. Radiographically a partially radiolucent proximal duodenal foreign body was suspected. Ultrasonographically, there was a foreign body at the level of the duodenal papilla and dilation of the common bile duct and cystic duct; a diagnosis of extrahepatic biliary tract obstruction secondary to a duodenal foreign body was made. Sonographic findings were confirmed at surgery and a duodenal foreign body was removed. This information defines duodenal foreign body as a cause of extrahepatic biliary obstruction in cats.
Resumo:
OBJECTIVES: To assess complication rate, risk factors for complications and outcome in dogs with oesophageal and gastric endoscopic foreign body (FB) removal. METHODS: Medical records of 102 dogs undergoing endoscopic removal of oesophageal and/or gastric FBs from March 2001 to November 2006 were retrospectively reviewed. All owners were contacted by telephone to provide follow-up information. RESULTS: West Highland white terriers, Yorkshire terriers and Bernese mountain dogs were over-represented compared to the hospital population. Endoscopy alone was successful in 92/102 dogs (90.2 per cent), whereas gastrotomy (but no oesophagotomy) was required in 10 dogs (9.8 per cent). Complications in 13/102 dogs (12.7 per cent) were perforation (8), oesophageal stricture (1), oesophageal diverticula (1), perioesophageal abscess (1), pneumothorax and pleural effusion (1) and respiratory arrest (1). Six dogs (all weighing <10 kg) had complications resulting in death or euthanasia. Bone FBs, bodyweight of less than 10 kg, and oesophageal or gastric FB in place for more than three days were significant risk factors for complications. Of the dogs available for follow-up (75/96), 92 per cent had no complications after discharge. CLINICAL SIGNIFICANCE: Endoscopic FB removal is associated with a low overall complication rate with bone FBs and bodyweight of less than 10 kg as significant risk factors.
Resumo:
OBJECTIVE: Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments. DESIGN: This comparative cross-sectional study retrospectively assessed 28 289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (μSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality. RESULTS: A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 μS, compared with 524 μS for digital chest radiography. CONCLUSIONS: LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.
Resumo:
CONTEXT: Death from corpora aliena in the larynx is a well-known entity in forensic pathology. The correct diagnosis of this cause of death is difficult without an autopsy, and misdiagnoses by external examination alone are common. OBJECTIVE: To determine the postmortem usefulness of modern imaging techniques in the diagnosis of foreign bodies in the larynx, multislice computed tomography, magnetic resonance imaging, and postmortem full-body computed tomography-angiography were performed. DESIGN: Three decedents with a suspected foreign body in the larynx underwent the 3 different imaging techniques before medicolegal autopsy. RESULTS: Multislice computed tomography has a high diagnostic value in the noninvasive localization of a foreign body and abnormalities in the larynx. The differentiation between neoplasm or soft foreign bodies (eg, food) is possible, but difficult, by unenhanced multislice computed tomography. By magnetic resonance imaging, the discrimination of the soft tissue structures and soft foreign bodies is much easier. In addition to the postmortem multislice computed tomography, the combination with postmortem angiography will increase the diagnostic value. CONCLUSIONS: Postmortem, cross-sectional imaging methods are highly valuable procedures for the noninvasive detection of corpora aliena in the larynx.
Resumo:
To assess the long-term clinical and radiologic findings after insertion of a bioresorbable polylactide plates P(L/DL)LA 70/30 implant (PolyMax) in the repair of orbital floor and wall defects, with special focus on stability and clinical signs of foreign-body reaction.
Resumo:
OBJECTIVES: The aim of the present study was to histologically evaluate and compare a new prototype collagen type I/III-containing equine- (EB) and a bovine- (BB) derived cancellous bone block in a dog model. MATERIALS AND METHODS: Four standardized box-shaped defects were bilaterally created at the buccal aspect of the alveolar ridge in the lower jaws of five beagle dogs and randomly allocated to either EB or BB. Each experimental site was covered by a native (non-crosslinked) collagen membrane and left to heal in a submerged position for 12 weeks. Dissected blocks were processed for semi-/and quantitative analyses. RESULTS: Both groups had no adverse clinical or histopathological events (i.e. inflammatory/foreign body reactions). BB specimens revealed no signs of biodegradation and were commonly embedded in a fibrous connective tissue. New bone formation and bony graft integration were minimal. In contrast, EB specimens were characterized by a significantly increased cell (i.e. osteoclasts and multinucleated giant cells)-mediated degradation of the graft material (P<0.001). The amount and extent of bone ingrowth was consistently higher in all EB specimens, but failed to reach statistical significance in comparison with the BB group (P>0.05). CONCLUSIONS: It was concluded that the application of EB may not be associated with an improved bone formation than BB.
Resumo:
We investigated the inflammatory response to, and the osteoinductive efficacies of, four polymers (collagen, Ethisorb, PLGA and Polyactive) that bore either an adsorbed (fast-release kinetics) or a calcium-phosphate-coating-incorporated (slow-release kinetics) depot of BMP-2. Titanium-plate-supported discs of each polymer (n = 6 per group) were implanted at an ectopic (subcutaneous) ossification site in rats (n = 48). Five weeks later, they were retrieved for a histomorphometric analysis of the volumes of ectopic bone and foreign-body giant cells (a gauge of inflammatory reactivity), and the degree of polymer degradation. For each polymer, the osteoinductive efficacy of BMP-2 was higher when it was incorporated into a coating than when it was directly adsorbed onto the material. This mode of BMP-2 carriage was consistently associated with an attenuation of the inflammatory response. For coated materials, the volume density of foreign-body giant cells was inversely correlated with the volume density of bone (r(2) = 0.96), and the volume density of bone was directly proportional to the surface-area density of the polymer (r(2) = 0.97). Following coating degradation, other competitive factors, such as the biocompatibility and the biodegradability of the polymer itself, came into play.
Resumo:
We describe a case of exhumation, performed to investigate the circumstances and cause of death, one year after burial. Post mortem computed tomography (PMCT) revealed a mass in the pharynx. Imaging directed the subsequent forensic autopsy to careful retrieval of a foreign body. Histological analysis revealed a non-cellular composition. The detection of foreign material in the pharynx and its composition indicated accidental, rather than natural death, secondary to choking on food. This unusual case illustrates how post mortem imaging can significantly contribute to forensic investigation and stresses the importance of interdisciplinary collaboration between forensic pathologists and radiologists.
Resumo:
Adhesions occur with a high incidence after intra-abdominal surgery but can also develop due to infections, radiation or for idiopathic reasons. The formation of adhesions is initiated by tissue damage and is the result of peritoneal tissue repair involving the activation of the inflammatory system and the coagulation cascade. Acute small bowel obstruction is one of the most common complications and should be diagnosed rapidly using clinical examination and radiological imaging. A complete obstruction is life threatening and in a high percentage of patients requires rapid surgical intervention by laparotomy or laparoscopy depending on the clinical situation and the patients history. Despite numerous investigations, there is no reliable, commonly used method to prevent intra-abdominal adhesions. Minimizing tissue damage and foreign body exposure, avoiding spillage of intestinal and biliary contents as well as a laparoscopic approach seem to have a beneficial effect on the formation of intra-abdominal adhesions.
Resumo:
Arterial hypertension is a chronic disease with a therapeutical challenge for the patient and the physician involved. Patient-independent techniques with good efficacy and tolerability are wanted. The autonomous nervous system insufficiently therapeutically exploited to date, is now approachable by two types of intervention: renal nerve ablation, an endovascular approach without remaining foreign body, and BAT, baroreflex activating therapy using an implantable device stimulating the carotid sinus. The blood pressure lowering potency of BAT appears more than with renal nerve ablation and also clinical study data are more prevalent. With both treatment options the patients having the most profit are insufficiently defined. Given this knowledge, any form of secondary hypertension needs to be excluded beforehand.
Resumo:
AIM: To evaluate the haemostatic efficacy and the histologic tissue responses after the application of different haemostatic agents used in periradicular surgery. METHODOLOGY: The study was conducted in the calvarium of six rabbits. Standardized bone defects (diameter 4 mm) were trephined, and different haemostatic agents were applied and compared with control defects: bone wax (left for 10 min), Stasis (ferric sulphate, left for 5 s), Expasyl (aluminium chloride, left for 2 min and left permanently in situ), and a combination of Expasyl (2 min) and Stasis (5 s). The sites were photographed before the application and after the removal of the haemostatic agents. Three independent examiners judged the initial and final bleeding (on the photographs) using a bleeding score for each site and treatment. The results were compared using Wilcoxon's signed rank test. For the histologic analysis, three animals were killed after 3 weeks and three animals after 12 weeks. Transverse, nondecalcified sections were stained with combined basic fuchsin and toluidine blue for descriptive histology. RESULTS: The most efficient haemorrhage control was provided by Expasyl in combination with Stasis and by Expasyl alone, whereas bone wax had the weakest bleeding reduction effect. The histologic analysis after 3 weeks demonstrated an inflammatory and foreign body tissue response towards all haemostatic agents. At 12 weeks, this tissue response was less pronounced but still present in sites treated with bone wax or Expasyl. In general, the inflammatory tissue reactions were limited to the bone defects, and never extended into the surrounding tissues. CONCLUSIONS: Expasyl alone or in combination with Stasis appeared to be the most efficient of tested agents to control the bleeding within the bony defects created in a rabbit calvarium model.
Resumo:
AIM: The purpose of this randomized split-mouth clinical trial was to determine the active tactile sensibility between single-tooth implants and opposing natural teeth and to compare it with the tactile sensibility of pairs of natural teeth on the contralateral side in the same mouth (intraindividual comparison). MATERIAL AND METHODS: The hypothesis was that the active tactile sensibilities of the implant side and control side are equivalent. Sixty two subjects (n=36 from Bonn, n=26 from Bern) with single-tooth implants (22 anterior and 40 posterior dental implants) were asked to bite on narrow copper foil strips varying in thickness (5-200 microm) and to decide whether or not they were able to identify a foreign body between their teeth. Active tactile sensibility was defined as the 50% threshold of correct answers estimated by means of the Weibull distribution. RESULTS: The results obtained for the interocclusal perception sensibility differed between subjects far more than they differed between natural teeth and implants in the same individual [implant/natural tooth: 16.7+/-11.3 microm (0.6-53.1 microm); natural tooth/natural tooth: 14.3+/-10.6 microm (0.5-68.2 microm)]. The intraindividual differences only amounted to a mean value of 2.4+/-9.4 microm (-15.1 to 27.5 microm). The result of our statistical calculations showed that the active tactile sensibility of single-tooth implants, both in the anterior and posterior region of the mouth, in combination with a natural opposing tooth is similar to that of pairs of opposing natural teeth (double t-test, equivalence margin: +/-8 microm, P<0.001, power >80%). Hence, the implants could be integrated in the stomatognathic control circuit.
Resumo:
In the United States, rumenocentesis has been recommended especially for early diagnosis of subacute rumen acidosis (SARA). The objective of the current study was to evaluate health risks due to the technique ofrumenocentesis and to measure pH in ruminal juice using a commercial indicator paper (Pehanon) and a pH electrode (reference method). After 11 dairy cows underwent rumenocentesis, the clinical status of those animals was evaluated daily, and cows were slaughtered as well as pathologically--anatomically examined on day 7. During the observation period, the following pathological clinical signs were evident: forced inspiration (3 cows), transient episode of hyperthermia (2 cows), increased tension of the abdominal wall (8 cows) and positive foreign body tests (3 cows). One cow had to be culled on day 7 because of severe generalised septic peritonitis spreading from the site of rumenocentesis. At slaughter, hematoma formation in the area of the puncture site was found in 9 out of 10 cows. It was concluded that the severe complications encountered with this technique do not legitimate rumenocentesis as a routine procedure for collection of rumen juice samples in cows under Swiss conditions. The correlation between the pH reference method and the commercial indicator paper was the high (r = 0.926).