84 resultados para Force of mortality

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Surgical risk scores, such as the logistic EuroSCORE (LES) and Society of Thoracic Surgeons Predicted Risk of Mortality (STS) score, are commonly used to identify high-risk or “inoperable” patients for transcatheter aortic valve implantation (TAVI). In Europe, the LES plays an important role in selecting patients for implantation with the Medtronic CoreValve System. What is less clear, however, is the role of the STS score of these patients and the relationship between the LES and STS. Objective The purpose of this study is to examine the correlation between LES and STS scores and their performance characteristics in high-risk surgical patients implanted with the Medtronic CoreValve System. Methods All consecutive patients (n = 168) in whom a CoreValve bioprosthesis was implanted between November 2005 and June 2009 at 2 centers (Bern University Hospital, Bern, Switzerland, and Erasmus Medical Center, Rotterdam, The Netherlands) were included for analysis. Patient demographics were recorded in a prospective database. Logistic EuroSCORE and STS scores were calculated on a prospective and retrospective basis, respectively. Results Observed mortality was 11.1%. The mean LES was 3 times higher than the mean STS score (LES 20.2% ± 13.9% vs STS 6.7% ± 5.8%). Based on the various LES and STS cutoff values used in previous and ongoing TAVI trials, 53% of patients had an LES ≥15%, 16% had an STS ≥10%, and 40% had an LES ≥20% or STS ≥10%. Pearson correlation coefficient revealed a reasonable (moderate) linear relationship between the LES and STS scores, r = 0.58, P < .001. Although the STS score outperformed the LES, both models had suboptimal discriminatory power (c-statistic, 0.49 for LES and 0.69 for STS) and calibration. Conclusions Clinical judgment and the Heart Team concept should play a key role in selecting patients for TAVI, whereas currently available surgical risk score algorithms should be used to guide clinical decision making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine risk factors for mortality in different age groups after thoracic endovascular aortic repair (TEVAR).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated Multidimensional Geriatric Assessment (MGA) as predictor of mortality and major adverse cardiovascular and cerebral events (MACCE) after transcatheter aortic valve implantation (TAVI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Retention of overdentures is important for patients' satisfaction. The study tested whether the clinical performance of retentive clips made of poly-ether-ether-ketone (PEEK) is superior to those made of poly-oxy-methylene (POM).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the association of QT interval corrected for heart rate (QT(c)) and resting heart rate (rHR) with mortality (all-causes, cardiovascular, cardiac, and ischaemic heart disease) in subjects with type 1 and type 2 diabetes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the association of apolipoprotein B (apo B) with mortality due to all causes, to cardiac disease and to ischaemic heart disease (IHD) in subjects with type 1 diabetes mellitus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to describe the all-cause mortality of participants in the Swiss Hepatitis C Cohort compared to the Swiss general population. Patients with hepatitis C virus (HCV) infection attending secondary and tertiary care centres in Switzerland. One thousand six hundred and forty-five patients with HCV infection were followed up for a mean of over 2 years. We calculated all-cause standardized mortality ratios (SMR) and 95% confidence intervals (CI) using age, sex and calendar year-specific Swiss all-cause mortality rates. Multivariable Poisson regression was used to model the variability of SMR by cirrhotic status, HCV genotype, infection with hepatitis B virus or HIV, injection drug use and alcohol intake. Sixty-one deaths were recorded out of 1645 participants. The crude all-cause SMR was 4.5 (95% CI: 3.5-5.8). Patients co-infected with HIV had a crude SMR of 20 (95% CI: 11.1-36.1). The SMR of 1.1 (95% CI: 0.63-2.03) for patients who were not cirrhotic, not infected with HBV or HIV, did not inject drugs, were not heavy alcohol consumers (of excess mortality. We found little evidence of excess mortality in hepatitis C infected patients who were not cirrhotic, in the absence of selected risk factors. Our findings emphasize the importance of providing appropriate preventive advice, such as counselling to avoid alcohol intake, in those infected with HCV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The cost-effectiveness of cast nonprecious frameworks has increased their prevalence in cemented implant crowns. The purpose of this study was to assess the effect of the design and height of the retentive component of a standard titanium implant abutment on the fit, possible horizontal rotation and retention forces of cast nonprecious alloy crowns prior to cementation. MATERIALS AND METHODS Two abutment designs were examined: Type A with a 6° taper and 8 antirotation planes (Straumann Tissue-Level RN) and Type B with a 7.5° taper and 1 antirotation plane (SICace implant). Both types were analyzed using 60 crowns: 20 with a full abutment height (6 mm), 20 with a medium abutment height (4 mm), and 20 with a minimal (2.5 mm) abutment height. The marginal and internal fit and the degree of possible rotation were evaluated by using polyvinylsiloxane impressions under a light microscope (magnification of ×50). To measure the retention force, a custom force-measuring device was employed. STATISTICAL ANALYSIS one-sided Wilcoxon rank-sum tests with Bonferroni-Holm corrections, Fisher's exact tests, and Spearman's rank correlation coefficient. RESULTS Type A exhibited increased marginal gaps (primary end-point: 55 ± 20 μm vs. 138 ± 59 μm, P < 0.001) but less rotation (P < 0.001) than Type B. The internal fit was also better for Type A than for Type B (P < 0.001). The retention force of Type A (2.49 ± 3.2 N) was higher (P = 0.019) than that of Type B (1.27 ± 0.84 N). Reduction in abutment height did not affect the variables observed. CONCLUSION Less-tapered abutments with more antirotation planes provide an increase in the retention force, which confines the horizontal rotation but widens the marginal gaps of the crowns. Thus, casting of nonprecious crowns with Type A abutments may result in clinically unfavorable marginal gaps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Because computed tomography (CT) has advantages for visualizing the manifestation of necrosis and local complications, a series of scoring systems based on CT manifestations have been developed for assessing the clinical outcomes of acute pancreatitis (AP), including the CT severity index (CTSI), modified CTSI, etc. Despite the internationally accepted CTSI having been successfully used to predict the overall mortality and disease severity of AP, recent literature has revealed the limitations of the CTSI. Using the Delphi method, we establish a new scoring system based on retrocrural space involvement (RCSI), and compared its effectiveness at evaluating the mortality and severity of AP with that of the CTSI. METHODS We reviewed CT images of 257 patients with AP taken within 3-5 days of admission in 2012. The RCSI scoring system, which includes assessment of infectious conditions involving the retrocrural space and the adjacent pleural cavity, was established using the Delphi method. Two radiologists independently assessed the RCSI and CTSI scores. The predictive points of the RCSI and CTSI scoring systems in evaluating the mortality and severity of AP were estimated using receiver operating characteristic (ROC) curves. PRINCIPAL FINDINGS The RCSI score can accurately predict the mortality and disease severity. The area under the ROC curve for the RCSI versus CTSI score was 0.962±0.011 versus 0.900±0.021 for predicting the mortality, and 0.888±0.025 versus 0.904±0.020 for predicting the severity of AP. Applying ROC analysis to our data showed that a RCSI score of 4 was the best cutoff value, above which mortality could be identified. CONCLUSION The Delphi method was innovatively adopted to establish a scoring system to predict the clinical outcome of AP. The RCSI scoring system can predict the mortality of AP better than the CTSI system, and the severity of AP equally as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In equine laminitis, the deep digital flexor muscle (DDFM) appears to have increased muscle force, but evidence-based confirmation is lacking. OBJECTIVES: The purpose of this study was to test if the DDFM of laminitic equines has an increased muscle force detectable by needle electromyography interference pattern analysis (IPA). ANIMALS AND METHODS: The control group included six Royal Dutch Sport horses, three Shetland ponies and one Welsh pony [10 healthy, sound adults weighing 411 ± 217 kg (mean ± SD) and aged 10 ± 5 years]. The laminitic group included three Royal Dutch Sport horses, one Friesian, one Haflinger, one Icelandic horse, one Welsh pony, one miniature Appaloosa and six Shetland ponies (14 adults, weight 310 ± 178 kg, aged 13 ± 6 years) with acute/chronic laminitis. The electromyography IPA measurements included firing rate, turns/second (T), amplitude/turn (M) and M/T ratio. Statistical analysis used a general linear model with outcomes transformed to geometric means. RESULTS: The firing rate of the total laminitic group was higher than the total control group. This difference was smaller for the ponies compared to the horses; in the horses, the geometric mean difference of the laminitic group was 1.73 [geometric 95% confidence interval (CI) 1.29-2.32], and in the ponies this value was 1.09 (geometric 95% CI 0.82-1.45). CONCLUSION AND CLINICAL RELEVANCE: In human medicine, an increased firing rate is characteristic of increased muscle force. Thus, the increased firing rate of the DDFM in the context of laminitis suggests an elevated muscle force. However, this seems to be only a partial effect as in this study, the unchanged turns/second and amplitude/turn failed to prove the recruitment of larger motor units with larger amplitude motor unit potentials in laminitic equids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The long-term safety of growth hormone treatment is uncertain. Raised risks of death and certain cancers have been reported inconsistently, based on limited data or short-term follow-up by pharmaceutical companies. PATIENTS AND METHODS The SAGhE (Safety and Appropriateness of Growth Hormone Treatments in Europe) study assembled cohorts of patients treated in childhood with recombinant human growth hormone (r-hGH) in 8 European countries since the first use of this treatment in 1984 and followed them for cause-specific mortality and cancer incidence. Expected rates were obtained from national and local general population data. The cohort consisted of 24,232 patients, most commonly treated for isolated growth failure (53%), Turner syndrome (13%) and growth hormone deficiency linked to neoplasia (12%). This paper describes in detail the study design, methods and data collection and discusses the strengths, biases and weaknesses consequent on this. CONCLUSION The SAGhE cohort is the largest and longest follow-up cohort study of growth hormone-treated patients with follow-up and analysis independent of industry. It forms a major resource for investigating cancer and mortality risks in r-hGH patients. The interpretation of SAGhE results, however, will need to take account of the methods of cohort assembly and follow-up in each country.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Strategies to improve risk prediction are of major importance in patients with heart failure (HF). Fibroblast growth factor 23 (FGF-23) is an endocrine regulator of phosphate and vitamin D homeostasis associated with an increased cardiovascular risk. We aimed to assess the prognostic effect of FGF-23 on mortality in HF patients with a particular focus on differences between patients with HF with preserved ejection fraction and patients with HF with reduced ejection fraction (HFrEF). METHODS AND RESULTS FGF-23 levels were measured in 980 patients with HF enrolled in the Ludwigshafen Risk and Cardiovascular Health (LURIC) study including 511 patients with HFrEF and 469 patients with HF with preserved ejection fraction and a median follow-up time of 8.6 years. FGF-23 was additionally measured in a second cohort comprising 320 patients with advanced HFrEF. FGF-23 was independently associated with mortality with an adjusted hazard ratio per 1-SD increase of 1.30 (95% confidence interval, 1.14-1.48; P<0.001) in patients with HFrEF, whereas no such association was found in patients with HF with preserved ejection fraction (for interaction, P=0.043). External validation confirmed the significant association with mortality with an adjusted hazard ratio per 1 SD of 1.23 (95% confidence interval, 1.02-1.60; P=0.027). FGF-23 demonstrated an increased discriminatory power for mortality in addition to N-terminal pro-B-type natriuretic peptide (C-statistic: 0.59 versus 0.63) and an improvement in net reclassification index (39.6%; P<0.001). CONCLUSIONS FGF-23 is independently associated with an increased risk of mortality in patients with HFrEF but not in those with HF with preserved ejection fraction, suggesting a different pathophysiologic role for both entities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were analyzed according to the type of tooth (incisors, canines, premolars, and molars). Additionally, a comparison between lubricated and unlubricated telescopic crowns was done. As maximum retention force value 29.98 N was recorded with a telescopic crown on a molar, while the minimum of 0.08 N was found with a specimen on a canine. The median value of retention force of all telescopic crowns reached 1.93 N with an interquartile distance of 4.35 N. No statistically significant difference between lubricated and unlubricated specimens was found. The results indicate that retention force values of telescopic crowns, measured in clinical practice, are often much lower than those cited in the literature. The measurements also show a wide range. Whether this proves to be a problem for the patient's quality of life or not can however only be established by a comparison of the presented results with a follow-up study involving measurement of intraoral retention and determination by e.g. oral health impact profile.