78 resultados para Fixed
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
INTRODUCTION: Fixed orthodontic appliances can alter the subgingival microbiota. Our aim was to compare the subgingival microbiota and clinical parameters in adolescent subjects at sites of teeth treated with orthodontic bands with margins at (OBM) or below the gingival margin (OBSM), or with brackets (OBR). METHODS: Microbial samples were collected from 33 subjects (ages, 12-18 years) in treatment more than 6 months. The microbiota was assessed by the DNA-DNA checkerboard hybridization method. RESULTS: Bacterial samples were taken from 83 OBR,103 OBSM, and 54 OBM sites. Probing pocket depths differed by orthodontic type (P <0.001) with mean values of 2.9 mm (SD, 0.6) at OBSM sites, 2.5 mm (SD, 0.6) at OBM sites, and 2.3 mm (SD, 0.5) at OBR sites. Only Actinomyces israelii (P <0.001) and Actinomyces naeslundii (P <0.001) had higher levels at OBR sites, whereas Neisseria mucosa had higher levels at sites treated with OBSM or OBM (P <0.001). Aggregatibacter actinomycetemcomitans was found in 25% of sites independent of the appliance. CONCLUSIONS: Different types of orthodontic appliances cause minor differences in the subgingival microbiota (A israelii and A naeslundii) and higher levels at sites treated with orthodontic brackets. More sites with bleeding on probing and deeper pockets were found around orthodontic bands.
Resumo:
Objectives: To evaluate the biological and technical complication rates of fixed dental prostheses (FDP) with end abutments or cantilever extensions on teeth (FDP-tt/cFDP-tt) on implants (FDP-ii/cFDP-ii) and tooth-implant-supported (FDP-ti/cFDP-ti) in patients treated for chronic periodontitis. Material and methods: From a cohort of 392 patients treated between 1978 and 2002 by graduate students, 199 were re-examined in 2005. Of these, 84 patients had received ceramo-metal FDPs (six groups). Results: At the re-evaluation, the mean age of the patients was 62 years (36.2–83.4). One hundred and seventy-five FDPs were seated (82 FDP-tt, 9 FDP-ii, 20 FDP-ti, 39 cFDP-tt, 15 cFDP-ii, 10 cFDP-ti). The mean observation time was 11.3 years; 21 FDPs were lost, and 46 technical and 50 biological complications occurred. Chances for the survival of the three groups of FDPs with end abutments were very high (risk for failure 2.8%, 0%, 5.6%). The probability to remain without complications and/or failure was 70.3%, 88.9% and 74.7% in FDPs with end abutments, but 49.8–25% only in FDPs with extensions at 10 years. Conclusions: In patients treated for chronic periodontitis and provided with ceramo-metal FDPs, high survival rates, especially for FDPs with end abutments, can be expected. The incidence rates of any negative events were increased drastically in the three groups with extension cFDPs (tt, ii, ti). Strategic decisions in the choice of a particular FDP design and the choice of teeth/implants as abutments appear to influence the risks for complications to be expected with fixed reconstruction. If possible, extensions on tooth abutments should be avoided or used only after a cautious clinical evaluation of all options.
Resumo:
The aim of this article was to assess the effect of wire adaptation on the lingual surfaces of mandibular anterior teeth with 3 types of lingual retainers on the development of vertical and labiolingual forces.
Resumo:
Our aim was to quantitatively determine the bisphenol-A (BPA) released from a light-cured orthodontic adhesive used to bond lingual fixed retainers.
Resumo:
Excessive cantilever lengths of fixed implant-supported prostheses may have functional and biomechanical disadvantages. This study reports the clinical outcomes of unconventional implants placed for distal support of a fixed implant-supported prostheses. Seven extraoral implants with intraosseous lengths of 2.5 to 4.0 mm were placed in four patients. Distal cantilevers had a mean length of 29.8 mm (range, 18.6 to 39.3 mm). No bone loss or other adverse events were found. The prosthetic plan was maintained in all patients. Within the limits of the employed research design, this concept seems to be a successful option for fixed complete implant-supported prosthesis treatment.
Resumo:
This ex vivo pilot study tested the influence of defect extension and quartz-fiber post placement (QFP) on the ex vivo survival rate and fracture resistance of root-treated upper central incisors served as abutments for zirconia 2-unit cantilever fixed partial dentures (2U-FPDs) exposed to 10 years of simulated clinical function.
Resumo:
The aims of this study were to reexamine patients who had received fixed dental prostheses (FDPs) more than 10 years prior, list the frequencies of observed technical and biologic failures and complications, and calculate the estimated failure and complication rates at 10 and 15 years.
Resumo:
To evaluate the clinical and radiographic changes at implants in posterior maxillary and mandibular areas supporting single-unit crowns (SCs) and fixed dental prostheses (FDPs) with one mesial or distal cantilever extension after an observation period of at least 3 years.
Resumo:
To systematically evaluate the existing evidence to answer the focused question: For a patient with a single tooth to be replaced, is the implant crown, based on economic considerations, preferred to a conventional fixed partial denture?
Resumo:
To assess the 5-year and 10-year survival and complication rates of implant-supported fixed reconstructions in partially and totally edentulous patients with regard to the optimal number and distribution of dental implants.
Resumo:
The objective of this systematic review was to assess the 5- and 10-year survival of implant-supported fixed dental prostheses (FDPs) and to describe the incidence of biological and technical complications.