75 resultados para Finding aids
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVES To establish whether complex signal processing is beneficial for users of bone anchored hearing aids. METHODS Review and analysis of two studies from our own group, each comparing a speech processor with basic digital signal processing (either Baha Divino or Baha Intenso) and a processor with complex digital signal processing (either Baha BP100 or Baha BP110 power). The main differences between basic and complex signal processing are the number of audiologist accessible frequency channels and the availability and complexity of the directional multi-microphone noise reduction and loudness compression systems. RESULTS Both studies show a small, statistically non-significant improvement of speech understanding in quiet with the complex digital signal processing. The average improvement for speech in noise is +0.9 dB, if speech and noise are emitted both from the front of the listener. If noise is emitted from the rear and speech from the front of the listener, the advantage of the devices with complex digital signal processing as opposed to those with basic signal processing increases, on average, to +3.2 dB (range +2.3 … +5.1 dB, p ≤ 0.0032). DISCUSSION Complex digital signal processing does indeed improve speech understanding, especially in noise coming from the rear. This finding has been supported by another study, which has been published recently by a different research group. CONCLUSIONS When compared to basic digital signal processing, complex digital signal processing can increase speech understanding of users of bone anchored hearing aids. The benefit is most significant for speech understanding in noise.
Resumo:
Early intervention can help to reduce the burden of disability in the older population, but many do not access preventive care. There is uncertainty over what factors influence case finding in older patients in general practice.
Resumo:
In order to facilitate and improve the use of antiretroviral therapy (ART), international recommendations are released and updated regularly. We aimed to study if adherence to the recommendations is associated with better treatment outcomes in the Swiss HIV Cohort Study (SHCS).
Resumo:
Intestinal infections with Toxocara cati and Toxocara canis in their definitive host (felids and canids, respectively) are diagnosed by egg identification in faeces using coproscopical techniques. The Toxocara species is assumed to comply with the species from which the examined faeces were obtained, i.e. T. cati in cats and T. canis in dogs. We isolated and measured Toxocara eggs from faecal samples of 36 cats and 35 dogs from Switzerland and identified the Toxocara species by PCR. Amongst the isolates originating from dogs, 24 (68.5%) were determined as T. canis and 11 (31.5%) as T. cati. In all samples originating from cats, only T. cati was identified. Based on PCR identification, eggs of T. canis (n=241) and T. cati (n=442) were measured, revealing statistically significant different (p<0.001) mean sizes of 62.3 by 72.7 mum for T. cati and 74.8 by 86.0 mum for T. canis eggs. Considering that coprophagy is not unusual for dogs, a considerable percentage of Toxocara infections coproscopically diagnosed in dogs, as well as assumptions on anthelminthic resistance in regularly treated dogs, might in fact relate to intestinal passages of eggs following the uptake of other animals' faeces.
Resumo:
Background Most adults infected with HIV achieve viral suppression within a year of starting combination antiretroviral therapy (cART). It is important to understand the risk of AIDS events or death for patients with a suppressed viral load. Methods and Findings Using data from the Collaboration of Observational HIV Epidemiological Research Europe (2010 merger), we assessed the risk of a new AIDS-defining event or death in successfully treated patients. We accumulated episodes of viral suppression for each patient while on cART, each episode beginning with the second of two consecutive plasma viral load measurements <50 copies/µl and ending with either a measurement >500 copies/µl, the first of two consecutive measurements between 50–500 copies/µl, cART interruption or administrative censoring. We used stratified multivariate Cox models to estimate the association between time updated CD4 cell count and a new AIDS event or death or death alone. 75,336 patients contributed 104,265 suppression episodes and were suppressed while on cART for a median 2.7 years. The mortality rate was 4.8 per 1,000 years of viral suppression. A higher CD4 cell count was always associated with a reduced risk of a new AIDS event or death; with a hazard ratio per 100 cells/µl (95% CI) of: 0.35 (0.30–0.40) for counts <200 cells/µl, 0.81 (0.71–0.92) for counts 200 to <350 cells/µl, 0.74 (0.66–0.83) for counts 350 to <500 cells/µl, and 0.96 (0.92–0.99) for counts ≥500 cells/µl. A higher CD4 cell count became even more beneficial over time for patients with CD4 cell counts <200 cells/µl. Conclusions Despite the low mortality rate, the risk of a new AIDS event or death follows a CD4 cell count gradient in patients with viral suppression. A higher CD4 cell count was associated with the greatest benefit for patients with a CD4 cell count <200 cells/µl but still some slight benefit for those with a CD4 cell count ≥500 cells/µl.
Resumo:
Discontinuation of maintenance therapy against toxoplasma encephalitis (TE) for individuals infected with human immunodeficiency virus (HIV) who are receiving successful anti-retroviral therapy is considered safe. Nevertheless, there are few published studies concerning this issue. Within the setting of the Swiss HIV Cohort Study, this report describes a prospective study of discontinuation of maintenance therapy against TE in patients with a sustained increase of CD4 counts to > 200 cells/microL and 14% of total lymphocytes, and no active lesions on cerebral magnetic resonance imaging (MRI). In addition to clinical evaluation, cerebral MRI was performed at baseline, and 1 and 6 months following discontinuation. Twenty-six AIDS patients with a history of TE agreed to participate, but three patients (11%) could not be enrolled because they still showed enhancing cerebral lesions without a clinical correlate. One patient refused MRI after 6 months while clinically asymptomatic. Among the remaining 22 patients who discontinued maintenance therapy, one relapsed after 3 months. During a total follow-up of 58 patient-years, there was no TE relapse among the patients who had remained clinically and radiologically free of relapse during the study. Thus, discontinuation of maintenance therapy against TE was generally safe, but may fail in a minority of patients. Patients who remain clinically and radiologically free of relapse at 6 months after discontinuation are unlikely to experience a relapse of TE.
Resumo:
OBJECTIVE: To generate anatomical data on the human middle ear and adjacent structures to serve as a base for the development and optimization of new implantable hearing aid transducers. Implantable middle ear hearing aid transducers, i.e. the equivalent to the loudspeaker in conventional hearing aids, should ideally fit into the majority of adult middle ears and should utilize the limited space optimally to achieve sufficiently high maximal output levels. For several designs, more anatomical data are needed. METHODS: Twenty temporal bones of 10 formalin-fixed adult human heads were scanned by a computed tomography system (CT) using a slide thickness of 0.63 mm. Twelve landmarks were defined and 24 different distances were calculated for each temporal bone. RESULTS: A statistical description of 24 distances in the adult human middle ear which may limit or influence the design of middle ear transducers is presented. Significant inter-individual differences but no significant differences for gender, side, age or degree of pneumatization of the mastoid were found. Distances, which were not analyzed for the first time in this study, were found to be in good agreement with the results of earlier studies. CONCLUSION: A data set describing the adult human middle ear anatomy quantitatively from the point of view of designers of new implantable hearing aid transducers has been generated. In principle, the method employed in this study using standard CT scans could also be used preoperatively to rule out exclusion criteria.