6 resultados para Figuera de moro -- Conreu

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quercetin is a potential chemopreventive and chemotherapeutic agent for pancreatic and other cancers. This study examined the distribution of quercetin in plasma, lung, liver, pancreas, and pancreatic cancer xenografts in a murine in vivo model and the uptake of quercetin in pancreatic cancer MiaPaCa-2 cells in a cellular in vitro model. Mice were randomly allocated to control or 0.2 and 1% quercetin diet groups utilizing the AIN93G-based diet (n = 12 per group) for 6 weeks. In addition, 6 mice from each group were injected weekly with the chemotherapeutic drug gemcitabine (120 mg/kg mouse, ip). MiaPaCa cells were collected from culture medium after cells were exposed to 30 muM quercetin for 0.5, 1, 2, 4, 8, and 24 h. Levels of quercetin and 3-O'-methylquercetin in mouse tissues and MiaPaCa-2 cells were measured by high-pressure liquid chromatography following enzymatic hydrolysis and then extraction. The study showed that quercetin is accumulated in pancreatic cancer cells and is absorbed in the circulating system, tumors, and tissues of pancreas, liver, and lung in vivo. A higher proportion of total quercetin found in tumors and pancreas is aglycones. Gemcitabine cotreatment with quercetin reduced absorption of quercetin in the mouse circulatory system and liver. Results from the study provide important information on the interpretation of the chemotherapeutic efficacy of quercetin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Deep brain stimulation (DBS) is highly successful in treating Parkinson's disease (PD), dystonia, and essential tremor (ET). Until recently implantable neurostimulators were nonrechargeable, battery-driven devices, with a lifetime of about 3-5 years. This relatively short duration causes problems for patients (e.g. programming and device-use limitations, unpredictable expiration, surgeries to replace depleted batteries). Additionally, these batteries (relatively large with considerable weight) may cause discomfort. To overcome these issues, the first rechargeable DBS device was introduced: smaller, lighter and intended to function for 9 years. Methods: Of 35 patients implanted with the rechargeable device, 21 (including 8 PD, 10 dystonia, 2 ET) were followed before and 3 months after surgery and completed a systematic survey of satisfaction with the rechargeable device. Results: Overall patient satisfaction was high (83.3 ± 18.3). Dystonia patients tended to have lower satisfaction values for fit and comfort of the system than PD patients. Age was significantly negatively correlated with satisfaction regarding process of battery recharging. Conclusions: Dystonia patients (generally high-energy consumption, severe problems at the DBS device end-of-life) are good, reliable candidates for a rechargeable DBS system. In PD, younger patients, without signs of dementia and good technical understanding, might have highest benefit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dedicated mission to investigate exoplanetary atmospheres represents a major milestone in our quest to understand our place in the universe by placing our Solar System in context and by addressing the suitability of planets for the presence of life. EChO—the Exoplanet Characterisation Observatory—is a mission concept specifically geared for this purpose. EChO will provide simultaneous, multi-wavelength spectroscopic observations on a stable platform that will allow very long exposures. The use of passive cooling, few moving parts and well established technology gives a low-risk and potentially long-lived mission. EChO will build on observations by Hubble, Spitzer and ground-based telescopes, which discovered the first molecules and atoms in exoplanetary atmospheres. However, EChO’s configuration and specifications are designed to study a number of systems in a consistent manner that will eliminate the ambiguities affecting prior observations. EChO will simultaneously observe a broad enough spectral region—from the visible to the mid-infrared—to constrain from one single spectrum the temperature structure of the atmosphere, the abundances of the major carbon and oxygen bearing species, the expected photochemically-produced species and magnetospheric signatures. The spectral range and resolution are tailored to separate bands belonging to up to 30 molecules and retrieve the composition and temperature structure of planetary atmospheres. The target list for EChO includes planets ranging from Jupiter-sized with equilibrium temperatures T eq up to 2,000 K, to those of a few Earth masses, with T eq \u223c 300 K. The list will include planets with no Solar System analog, such as the recently discovered planets GJ1214b, whose density lies between that of terrestrial and gaseous planets, or the rocky-iron planet 55 Cnc e, with day-side temperature close to 3,000 K. As the number of detected exoplanets is growing rapidly each year, and the mass and radius of those detected steadily decreases, the target list will be constantly adjusted to include the most interesting systems. We have baselined a dispersive spectrograph design covering continuously the 0.4–16 μm spectral range in 6 channels (1 in the visible, 5 in the InfraRed), which allows the spectral resolution to be adapted from several tens to several hundreds, depending on the target brightness. The instrument will be mounted behind a 1.5 m class telescope, passively cooled to 50 K, with the instrument structure and optics passively cooled to \u223c45 K. EChO will be placed in a grand halo orbit around L2. This orbit, in combination with an optimised thermal shield design, provides a highly stable thermal environment and a high degree of visibility of the sky to observe repeatedly several tens of targets over the year. Both the baseline and alternative designs have been evaluated and no critical items with Technology Readiness Level (TRL) less than 4–5 have been identified. We have also undertaken a first-order cost and development plan analysis and find that EChO is easily compatible with the ESA M-class mission framework.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The risk factors and clinical sequelae of gastrointestinal bleeding (GIB) in the current era of drug-eluting stents, prolonged dual antiplatelet therapy, and potent P2Y12 inhibitors are not well established. We determined the frequency, predictors, and clinical impact of GIB after percutaneous coronary interventions (PCIs) in a contemporary cohort of consecutive patients treated with unrestricted use of drug-eluting stents. METHODS AND RESULTS Between 2009 and 2012, all consecutive patients undergoing PCI were prospectively included in the Bern PCI Registry. Bleeding Academic Research Consortium (BARC) GIB and cardiovascular outcomes were recorded within 1 year of follow-up. Among 6212 patients, 84.1% received new-generation drug-eluting stents and 19.5% received prasugrel. At 1 year, GIB had occurred in 65 patients (1.04%); 70.8% of all events and 84.4% of BARC ≥3B events were recorded >30 days after PCI. The majority of events (64.4%) were related to upper GIB with a more delayed time course compared with lower GIB. Increasing age, previous GIB, history of malignancy, smoking, and triple antithrombotic therapy (ie, oral anticoagulation plus dual antiplatelet therapy) were independent predictors of GIB in multivariable analysis. GIB was associated with increased all-cause mortality (adjusted hazard ratio, 3.40; 95% confidence interval, 1.67-6.92; P=0.001) and the composite of death, myocardial infarction, or stroke (adjusted hazard ratio, 3.75; 95% confidence interval, 1.99-7.07; P<0.001) and was an independent predictor of all-cause mortality during 1 year. CONCLUSIONS Among unselected patients undergoing PCI, GIB has a profound effect on prognosis. Triple antithrombotic therapy emerged as the single drug-related predictor of GIB in addition to patient-related risk factors within 1 year of PCI. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02241291.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Cardiac troponin detected by new-generation, highly sensitive assays predicts clinical outcomes among patients with stable coronary artery disease (SCAD) treated medically. The prognostic value of baseline high-sensitivity cardiac troponin T (hs-cTnT) elevation in SCAD patients undergoing elective percutaneous coronary interventions is not well established. This study assessed the association of preprocedural levels of hs-cTnT with 1-year clinical outcomes among SCAD patients undergoing percutaneous coronary intervention. METHODS AND RESULTS Between 2010 and 2014, 6974 consecutive patients were prospectively enrolled in the Bern Percutaneous Coronary Interventions Registry. Among patients with SCAD (n=2029), 527 (26%) had elevated preprocedural hs-cTnT above the upper reference limit of 14 ng/L. The primary end point, mortality within 1 year, occurred in 20 patients (1.4%) with normal hs-cTnT versus 39 patients (7.7%) with elevated baseline hs-cTnT (P<0.001). Patients with elevated hs-cTnT had increased risks of all-cause (hazard ratio 5.73; 95% confidence intervals 3.34-9.83; P<0.001) and cardiac mortality (hazard ratio 4.68; 95% confidence interval 2.12-10.31; P<0.001). Preprocedural hs-TnT elevation remained an independent predictor of 1-year mortality after adjustment for relevant risk factors, including age, sex, and renal failure (adjusted hazard ratio 2.08; 95% confidence interval 1.10-3.92; P=0.024). A graded mortality risk was observed across higher tertiles of elevated preprocedural hs-cTnT, but not among patients with hs-cTnT below the upper reference limit. CONCLUSIONS Preprocedural elevation of hs-cTnT is observed in one fourth of SCAD patients undergoing elective percutaneous coronary intervention. Increased levels of preprocedural hs-cTnT are proportionally related to the risk of death and emerged as independent predictors of all-cause mortality within 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02241291.