19 resultados para False-door
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The aim of the study is to evaluate midterm results with regard to false-lumen status of a combined vascular and endovascular approach for the treatment of acute type A aortic dissection.
Resumo:
BACKGROUND: In view of the obvious practical advantages, the most common test for hematuria is currently a reagent strip. METHODS: A standardized microscopic examination of the sediment was performed in 20 asymptomatic children referred for evaluation of chronic isolated microhematuria detected by means of a reagent strip. RESULTS: In 6 of the 20 children the microscopic examination failed to confirm the result of the dipstick test. CONCLUSIONS: Confirmation for the presence of hematuria by microscopy is the most important step in children with a positive dipstick for urinary blood.
Resumo:
The association of simian virus 40 (SV40) with malignant pleural mesothelioma is currently under debate. In some malignancies of viral aetiology, viral DNA can be detected in the patients' serum or plasma. To characterize the prevalence of SV40 in Swiss mesothelioma patients, we optimized a real-time PCR for quantitative detection of SV40 DNA in plasma, and used a monoclonal antibody for immunohistochemical detection of SV40 in mesothelioma tissue microarrays. Real-time PCR was linear over five orders of magnitude, and sensitive to a single gene copy. Repeat PCR determinations showed excellent reproducibility. However, SV40 status varied for independent DNA isolates of single samples. We noted that SV40 detection rates by PCR were drastically reduced by the implementation of strict room compartmentalization and decontamination procedures. Therefore, we systematically addressed common sources of contamination and found no cross-reactivity with DNA of other polyomaviruses. Contamination during PCR was rare and plasmid contamination was infrequent. SV40 DNA was reproducibly detected in only 4 of 78 (5.1%) plasma samples. SV40 DNA levels were low and not consistently observed in paired plasma and tumour samples from the same patient. Immunohistochemical analysis revealed a weak but reproducible SV40 staining in 16 of 341 (4.7%) mesotheliomas. Our data support the occurrence of non-reproducible SV40 PCR amplifications and underscore the importance of proper sample handling and analysis. SV40 DNA and protein were found at low prevalence (5%) in plasma and tumour tissue, respectively. This suggests that SV40 does not appear to play a major role in the development of mesothelioma.
Resumo:
We evaluated a double screening strategy for carriage of methicillin-resistant Staphylococcus aureus (MRSA) in patients exposed to a newly detected MRSA carrier. If the first screening of the exposed patient yielded negative results, screening was repeated 4 days later. This strategy detected 12 (28%) of the 43 new MRSA carriers identified during the study period. The results suggest that there is an incubation period before MRSA carriage is detectable.
Resumo:
Robust evidence from a range of climate–carbon cycle models shows that the maximum warming relative to pre-industrial times caused by the emissions of carbon dioxide is nearly proportional to the total amount of emitted anthropogenic carbon (1, 2). This proportionality is a reasonable approximation for simulations covering many emissions scenarios for the time frame 1750 to 2500 (1). This linear relationship is remarkable given the different complexities of the models and the wide range of emissions scenarios considered. It has direct implications for the possibility of achieving internationally agreed climate targets such as those mentioned in the Copenhagen Accord and the Cancun Agreements (3, 4). Here I explain some of the implications of the linear relationship between peak warming and total cumulative carbon emissions.
Resumo:
BACKGROUND Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. METHODS In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. RESULTS Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. CONCLUSIONS The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.
Resumo:
BACKGROUND AND PURPOSE Inverse relationship between onset-to-door time (ODT) and door-to-needle time (DNT) in stroke thrombolysis was reported from various registries. We analyzed this relationship and other determinants of DNT in dedicated stroke centers. METHODS Prospectively collected data of consecutive ischemic stroke patients from 10 centers who received IV thrombolysis within 4.5 hours from symptom onset were merged (n=7106). DNT was analyzed as a function of demographic and prehospital variables using regression analyses, and change over time was considered. RESULTS In 6348 eligible patients with known treatment delays, median DNT was 42 minutes and kept decreasing steeply every year (P<0.001). Median DNT of 55 minutes was observed in patients with ODT ≤30 minutes, whereas it declined for patients presenting within the last 30 minutes of the 3-hour time window (median, 33 minutes) and of the 4.5-hour time window (20 minutes). For ODT within the first 30 minutes of the extended time window (181-210 minutes), DNT increased to 42 minutes. DNT was stable for ODT for 30 to 150 minutes (40-45 minutes). We found a weak inverse overall correlation between ODT and DNT (R(2)=-0.12; P<0.001), but it was strong in patients treated between 3 and 4.5 hours (R(2)=-0.75; P<0.001). ODT was independently inversely associated with DNT (P<0.001) in regression analysis. Octogenarians and women tended to have longer DNT. CONCLUSIONS DNT was decreasing steeply over the last years in dedicated stroke centers; however, significant oscillations of in-hospital treatment delays occurred at both ends of the time window. This suggests that further improvements can be achieved, particularly in the elderly.