52 resultados para False positive

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In view of the obvious practical advantages, the most common test for hematuria is currently a reagent strip. METHODS: A standardized microscopic examination of the sediment was performed in 20 asymptomatic children referred for evaluation of chronic isolated microhematuria detected by means of a reagent strip. RESULTS: In 6 of the 20 children the microscopic examination failed to confirm the result of the dipstick test. CONCLUSIONS: Confirmation for the presence of hematuria by microscopy is the most important step in children with a positive dipstick for urinary blood.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The association of simian virus 40 (SV40) with malignant pleural mesothelioma is currently under debate. In some malignancies of viral aetiology, viral DNA can be detected in the patients' serum or plasma. To characterize the prevalence of SV40 in Swiss mesothelioma patients, we optimized a real-time PCR for quantitative detection of SV40 DNA in plasma, and used a monoclonal antibody for immunohistochemical detection of SV40 in mesothelioma tissue microarrays. Real-time PCR was linear over five orders of magnitude, and sensitive to a single gene copy. Repeat PCR determinations showed excellent reproducibility. However, SV40 status varied for independent DNA isolates of single samples. We noted that SV40 detection rates by PCR were drastically reduced by the implementation of strict room compartmentalization and decontamination procedures. Therefore, we systematically addressed common sources of contamination and found no cross-reactivity with DNA of other polyomaviruses. Contamination during PCR was rare and plasmid contamination was infrequent. SV40 DNA was reproducibly detected in only 4 of 78 (5.1%) plasma samples. SV40 DNA levels were low and not consistently observed in paired plasma and tumour samples from the same patient. Immunohistochemical analysis revealed a weak but reproducible SV40 staining in 16 of 341 (4.7%) mesotheliomas. Our data support the occurrence of non-reproducible SV40 PCR amplifications and underscore the importance of proper sample handling and analysis. SV40 DNA and protein were found at low prevalence (5%) in plasma and tumour tissue, respectively. This suggests that SV40 does not appear to play a major role in the development of mesothelioma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Acute type A aortic dissection is a serious emergency with a mortality rate of up to 40% within the first 24 h when left untreated. Surgical therapy needs to be initiated promptly. Due to this urgent situation, preoperative evaluation of the coronary arteries is not routinely performed in these patients. The aim of this study was to evaluate the accuracy of 64-slice computed tomography angiography (CTA) for postoperative coronary artery assessment in these patients. Ten consecutive patients with two or more cardiovascular risk factors were prospectively enrolled. Patients had type A aortic dissection treated surgically with a supracoronary graft of the ascending aorta. Performance of CTA to exclude significant stenosis (>50% lumen narrowing) and/or coronary artery dissection was compared with quantitative coronary angiography. A total of 147 segments were evaluated. Three segments (2%) were excluded from analysis. CTA correctly assessed one of three significant stenoses in three patients and correctly excluded coronary artery disease (CAD) in six of ten patients. One patient was rated false positive. Overall accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT for identifying coronary artery disease by segment was 98%, 33%, 99%, 50%, and 99%, respectively (P<0.05). By patient, it was 70%, 33%, 86%, 50%, and 75%, respectively. No coronary artery dissection was found. Noninvasive CTA may be a viable alternative to conventional angiography for postoperative coronary artery evaluation in patients with surgically treated type A aortic dissection and cardiovascular risk factors. An NPV of 99% should allow for reliable exclusion of CAD. Further studies with higher patient numbers are warranted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To evaluate diffusion-weighted magnetic resonance (MR) imaging of the human placenta in fetuses with and fetuses without intrauterine growth restriction (IUGR) who were suspected of having placental insufficiency. MATERIALS AND METHODS: The study was approved by the local ethics committee, and written informed consent was obtained. The authors retrospectively evaluated 1.5-T fetal MR images from 102 singleton pregnancies (mean gestation ± standard deviation, 29 weeks ± 5; range, 21-41 weeks). Morphologic and diffusion-weighted MR imaging were performed. A region of interest analysis of the apparent diffusion coefficient (ADC) of the placenta was independently performed by two observers who were blinded to clinical data and outcome. Placental insufficiency was diagnosed if flattening of the growth curve was detected at obstetric ultrasonography (US), if the birth weight was in the 10th percentile or less, or if fetal weight estimated with US was below the 10th percentile. Abnormal findings at Doppler US of the umbilical artery and histopathologic examination of specimens from the placenta were recorded. The ADCs in fetuses with placental insufficiency were compared with those in fetuses of the same gestational age without placental insufficiency and tested for normal distribution. The t tests and Pearson correlation coefficients were used to compare these results at 5% levels of significance. RESULTS: Thirty-three of the 102 pregnancies were ultimately categorized as having an insufficient placenta. MR imaging depicted morphologic changes (eg, infarction or bleeding) in 27 fetuses. Placental dysfunction was suspected in 33 fetuses at diffusion-weighted imaging (mean ADC, 146.4 sec/mm(2) ± 10.63 for fetuses with placental insufficiency vs 177.1 sec/mm(2) ± 18.90 for fetuses without placental insufficiency; P < .01, with one false-positive case). The use of diffusion-weighted imaging in addition to US increased sensitivity for the detection of placental insufficiency from 73% to 100%, increased accuracy from 91% to 99%, and preserved specificity at 99%. CONCLUSION: Placental dysfunction associated with growth restriction is associated with restricted diffusion and reduced ADC. A decreased ADC used as an early marker of placental damage might be indicative of pregnancy complications such as IUGR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tick-borne encephalitis (TBE), a viral infection of the central nervous system, is endemic in many Eurasian countries. In Switzerland, TBE risk areas have been characterized by geographic mapping of clinical cases. Since mass vaccination should significantly decrease the number of TBE cases, alternative methods for exposure risk assessment are required. We established a new PCR-based test for the detection of TBE virus (TBEV) in ticks. The protocol involves an automated, high-throughput nucleic acid extraction method (QIAsymphony SP system) and a one-step duplex real-time reverse transcription-PCR (RT-PCR) assay for the detection of European subtype TBEV, including an internal process control. High usability, reproducibility, and equivalent performance for virus concentrations down to 5 x 10(3) viral genome equivalents/microl favor the automated protocol compared to the modified guanidinium thiocyanate-phenol-chloroform extraction procedure. The real-time RT-PCR allows fast, sensitive (limit of detection, 10 RNA copies/microl), and specific (no false-positive test results for other TBEV subtypes, other flaviviruses, or other tick-transmitted pathogens) detection of European subtype TBEV. The new detection method was applied in a national surveillance study, in which 62,343 Ixodes ricinus ticks were screened for the presence of TBE virus. A total of 38 foci of endemicity could be identified, with a mean virus prevalence of 0.46%. The foci do not fully agree with those defined by disease mapping. Therefore, the proposed molecular test procedure constitutes a prerequisite for an appropriate TBE surveillance. Our data are a unique complement of human TBE disease case mapping in Switzerland.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dopamine has long held a prominent role in the interpretation of schizophrenia and other psychoses. Clinical studies on confabulation and disorientation, disorders marked by a confusion of reality in thinking, indicated that the ability to keep thinking in phase with reality depends on a process suppressing the interference of upcoming memories that do not refer to ongoing reality. A host of animal studies and a recent clinical study suggested that this suppression might correspond to the phasic inhibition of dopaminergic neurons in response to the absence of expected outcomes. In this study, we tested healthy subjects with a difficult version of a memory paradigm on which confabulating patients had failed. Subjects participated in three test sessions, in which they received in double-blind, randomized fashion L-dopa, risperidone, or placebo. We found that l-dopa, in comparison with risperidone, impaired performance in a highly specific way, which corresponded to the pattern of patients with reality confusion. Specifically, they had an increase of false positive responses, while overall memory performance and reaction times were unaffected. We conclude that dopaminergic transmission influences the ability to rapidly adapt thinking to ongoing reality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Intraoperative examination of sentinel axillary lymph nodes can be done by imprint cytology, frozen section, or, most recently, by PCR-based amplification of a cytokeratin signal. Using this technique, benign epithelial inclusions, representing mammary tissue displaced along the milk line, will likely generate a positive PCR signal and lead to a false-positive diagnosis of metastatic disease. To better appreciate the incidence of ectopic epithelial inclusions in axillary lymph nodes, we have performed an autopsy study, examining on 100 μm step sections 3,904 lymph nodes obtained from 160 axillary dissections in 80 patients. The median number of lymph nodes per axilla was 23 (15, 6, and 1 in levels 1, 2, and 3, respectively). A total of 30,450 hematoxylin-eosin stained slides were examined, as well as 8,825 slides immunostained with pan-cytokeratin antibodies. Despite this meticulous work-up, not a single epithelial inclusion was found in this study, suggesting that the incidence of such inclusions is much lower than the assumed 5% reported in the literature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To determine interobserver and intraobserver agreement for results of low-field magnetic resonance imaging (MRI) in dogs with and without disk-associated wobbler syndrome (DAWS). DESIGN: Validation study. ANIMALS: 21 dogs with and 23 dogs without clinical signs of DAWS. PROCEDURES: For each dog, MRI of the cervical vertebral column was performed. The MRI studies were presented in a randomized sequence to 4 board-certified radiologists blinded to clinical status. Observers assessed degree of disk degeneration, disk-associated and dorsal compression, alterations in intraspinal signal intensity (ISI), vertebral body abnormalities, and new bone formation and categorized each study as originating from a clinically affected or clinically normal dog. Interobserver agreement was calculated for 44 initial measurements for each observer. Intraobserver agreement was calculated for 11 replicate measurements for each observer. RESULTS: There was good interobserver agreement for ratings of disk degeneration and vertebral body abnormalities and moderate interobserver agreement for ratings of disk-associated compression, dorsal compression, alterations in ISI, new bone formation, and suspected clinical status. There was very good intraobserver agreement for ratings of disk degeneration, disk-associated compression, alterations in ISI, vertebral body abnormalities, and suspected clinical status. There was good intraobserver agreement for ratings of dorsal compression and new bone formation. Two of 21 clinically affected dogs were erroneously categorized as clinically normal, and 4 of 23 clinically normal dogs were erroneously categorized as clinically affected. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that variability exists among observers with regard to results of MRI in dogs with DAWS and that MRI could lead to false-positive and false-negative assessments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A real-time polymerase chain reaction (PCR) assay was developed for rapid identification of Bacillus anthracis in environmental samples. These samples often harbor Bacillus cereus bacteria closely related to B. anthracis, which may hinder its specific identification by resulting in false positive signals. The assay consists of two duplex real-time PCR: the first PCR allows amplification of a sequence specific of the B. cereus group (B. anthracis, B. cereus, Bacillus thuringiensis, Bacillus weihenstephanensis, Bacillus pseudomycoides, and Bacillus mycoides) within the phosphoenolpyruvate/sugar phosphotransferase system I gene and a B. anthracis specific single nucleotide polymorphism within the adenylosuccinate synthetase gene. The second real-time PCR assay targets the lethal factor gene from virulence plasmid pXO1 and the capsule synthesis gene from virulence plasmid pXO2. Specificity of the assay is enhanced by the use of minor groove binding probes and/or locked nucleic acids probes. The assay was validated on 304 bacterial strains including 37 B. anthracis, 67 B. cereus group, 54 strains of non-cereus group Bacillus, and 146 Gram-positive and Gram-negative bacteria strains. The assay was performed on various environmental samples spiked with B. anthracis or B. cereus spores. The assay allowed an accurate identification of B. anthracis in environmental samples. This study provides a rapid and reliable method for improving rapid identification of B. anthracis in field operational conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. MATERIAL AND METHODS: This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. RESULTS: 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. DISCUSSION: The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our findings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Cystic fibrosis (CF) is associated with at least 1 pathogen point sequence variant on each CFTR allele. Some symptomatic patients, however, have only 1 detectable pathogen sequence variant and carry, on the other allele, a large deletion that is not detected by conventional screening methods. METHODS: For relative quantitative real-time PCR detection of large deletions in the CFTR gene, we designed DNA-specific primers for each exon of the gene and primers for a reference gene (beta2-microglobulin). For PCR we used a LightCycler system (Roche) and calculated the gene-dosage ratio of CFTR to beta2-microglobulin. We tested the method by screening all 27 exons in 3 healthy individuals and 2 patients with only 1 pathogen sequence variant. We then performed specific deletion screenings in 10 CF patients with known large deletions and a blinded analysis in which we screened 24 individuals for large deletions by testing 8 of 27 exons. RESULTS: None of the ratios for control samples were false positive (for deletions or duplications); moreover, for all samples from patients with known large deletions, the calculated ratios for deleted exons were close to 0.5. In addition, the results from the blinded analysis demonstrated that our method can also be used for the screening of single individuals. CONCLUSIONS: The LightCycler assay allows reliable and rapid screening for large deletions in the CFTR gene and detects the copy number of all 27 exons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The examination of urine in children can be very complex, due to the difficulty to obtain clean urine specimens in infants and toddlers. Clean catch is an easy system to obtain urine but patience is needed. Transurethral catheterization or suprapubic aspiration is useful in infants and toddlers with sign of pyelonephritis. Urine bag specimens are not useful in the diagnosis of urinary tract infection because of the high rate of false positive cultures. The 24 hours urine collection is frequently replaced by a spot urine and the ratio of the measured substances with the urine creatinine are calculated. Urine microscopy is needed for the evaluation of pathological results in the dipstick testing: confirm that red urine is due to haematuria by demonstration of red blood cells on urine microscopy, dysmorphic cells and red-cell casts are pathognomonic of glomerular bleeding, white-cell casts signify glomerular inflammation and bacteria are easily seen in unstained urine. A urine culture is pathologic if the colony count exceeds 10(4) in the transurethral catheterization or clean void. In the suprapubic aspiration is any number of colony pathologic. Urate crystals in the urine of infants may cause a pink discoloration to nappies. Urine screenings are not very useful and should be performed only at the age of 5 years or by sexual-active adolescents.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Publication bias and related bias in meta-analysis is often examined by visually checking for asymmetry in funnel plots of treatment effect against its standard error. Formal statistical tests of funnel plot asymmetry have been proposed, but when applied to binary outcome data these can give false-positive rates that are higher than the nominal level in some situations (large treatment effects, or few events per trial, or all trials of similar sizes). We develop a modified linear regression test for funnel plot asymmetry based on the efficient score and its variance, Fisher's information. The performance of this test is compared to the other proposed tests in simulation analyses based on the characteristics of published controlled trials. When there is little or no between-trial heterogeneity, this modified test has a false-positive rate close to the nominal level while maintaining similar power to the original linear regression test ('Egger' test). When the degree of between-trial heterogeneity is large, none of the tests that have been proposed has uniformly good properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to evaluate the diagnostic accuracy of coronary binary in-stent restenosis (ISR) with angiography using 64-slice multislice computed tomography coronary angiography (CTCA) compared with invasive coronary angiography (ICA). BACKGROUND: A noninvasive detection of ISR would result in an easier and safer way to conduct patient follow-up. METHODS: We performed CTCA in 81 patients after stent implantation, and 125 stented lesions were scanned. Two sets of images were reconstructed with different types of convolution kernels. On CTCA, neointimal proliferation was visually evaluated according to luminal contrast attenuation inside the stent. Lesions were graded as follows: grade 1, none or slight neointimal proliferation; grade 2, neointimal proliferation with no significant stenosis (<50%); grade 3, neointimal proliferation with moderate stenosis (> or =50%); and grade 4, neointimal proliferation with severe stenosis (> or =75%). Grades 3 and 4 were considered binary ISR. The diagnostic accuracy of CTCA compared with ICA was evaluated. RESULTS: By ICA, 24 ISRs were diagnosed. Sensitivity, specificity, positive predictive value, and negative predictive value were 92%, 81%, 54%, and 98% for the overall population, whereas values were 91%, 93%, 77%, and 98% when excluding unassessable segments (15 segments, 12%). For assessable segments, CTCA correctly diagnosed 20 of the 22 ISRs detected by ICA. Six lesions without ISR were overestimated as ISR by CTCA. As the grade of neointimal proliferation by CTCA increases, the median value of percent diameter stenosis increased linearly. CONCLUSIONS: Binary ISR can be excluded with high probability by CTCA, with a moderate rate of false-positive results.