22 resultados para Fair value measurement

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The ECHo Collaboration (Electron Capture 163Ho aims to investigate the calorimetric spectrum following the electron capture decay of 163Ho to determine the mass of the electron neutrino. The size of the neutrino mass is reflected in the endpoint region of the spectrum, i.e., the last few eV below the transition energy. To check for systematic uncertainties, an independent determination of this transition energy, the Q-value, is mandatory. Using the TRIGA-TRAP setup, we demonstrate the feasibility of performing this measurement by Penning-trap mass spectrometry. With the currently available, purified 163Ho sample and an improved laser ablation mini-RFQ ion source, we were able to perform direct mass measurements of 163Ho and 163Dy with a sample size of less than 1017 atoms. The measurements were carried out by determining the ratio of the cyclotron frequencies of the two isotopes to those of carbon cluster ions using the time-of-flight ion cyclotron resonance method. The obtained mass excess values are ME(163Ho)= −66379.3(9) keV and ME(163Dy)= −66381.7(8) keV. In addition, the Q-value was measured for the first time by Penning-trap mass spectrometry to be Q = 2.5(7) keV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were analyzed according to the type of tooth (incisors, canines, premolars, and molars). Additionally, a comparison between lubricated and unlubricated telescopic crowns was done. As maximum retention force value 29.98 N was recorded with a telescopic crown on a molar, while the minimum of 0.08 N was found with a specimen on a canine. The median value of retention force of all telescopic crowns reached 1.93 N with an interquartile distance of 4.35 N. No statistically significant difference between lubricated and unlubricated specimens was found. The results indicate that retention force values of telescopic crowns, measured in clinical practice, are often much lower than those cited in the literature. The measurements also show a wide range. Whether this proves to be a problem for the patient's quality of life or not can however only be established by a comparison of the presented results with a follow-up study involving measurement of intraoral retention and determination by e.g. oral health impact profile.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reduced exercise tolerance and dyspnea during exercise are hallmarks of heart failure syndrome. Exercise capacity and various parameters of cardiopulmonary response to exercise are of important prognostic value. All the available parameters only indirectly reflect left ventricular dysfunction and hemodynamic adaptation to an increased demand. Noninvasive assessment of cardiac output, especially during an incremental exercise stress test, would allow the direct measure of cardiac reserve and may become the gold standard for prognostic evaluation in the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The radiological determination of foreign objects in corpses can be difficult if they are fragmented or deformed. With multislice computed tomography, radiodensities--referred to as Hounsfield units (HU)--can be measured. We examined the possibility of differentiating 21 frequently occurring foreign bodies, such as metals, rocks, and different manmade materials by virtue of their HU values. Gold, steel, and brass showed mean HU values of 30671-30710 (upper measurable limit), mean HU values for steel, silver, copper, and limestone were 20346, 16949, 14033, and 2765, respectively. The group consisting of objects, such as aluminum, tarmac, car front-window glass, and other rocks, displayed mean HU values of 2329-2131 HU. The mean HU value of bottle glass and car side-window glass was 2088, whereas windowpane glass was 493. HU value determination may therefore help in preautopsy differentiation between case-relevant and irrelevant foreign bodies and thus be useful for autopsy planning and extraction of the objects in question.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We examine the impact of identity preferences on the interrelation between incentives and performance measurement. In our model, a manager identifies with an organization and loses utility to the extent that his actions conflict with effort-standards issued by the principal. Contrary to prior arguments in the literature, we find conditions under which a manager who identifies strongly with the organization receives stronger incentives and faces more performance evaluation reports than a manager who does not identify with the organization. Our theory predicts that managers who experience events that boost their identification with the firm can decrease their effort in short-term value creation. We also find that firms are more likely to employ less precise but more congruent performance measures, such as stock prices, when contracting with managers who identify little with the organization. In contrast, they use more precise but less congruent measures, such as accounting earnings, when contracting with managers who identify strongly with the firm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molybdenum isotopes are increasingly widely applied in Earth Sciences. They are primarily used to investigate the oxygenation of Earth's ocean and atmosphere. However, more and more fields of application are being developed, such as magmatic and hydrothermal processes, planetary sciences or the tracking of environmental pollution. Here, we present a proposal for a unifying presentation of Mo isotope ratios in the studies of mass-dependent isotope fractionation. We suggest that the δ98/95Mo of the NIST SRM 3134 be defined as +0.25‰. The rationale is that the vast majority of published data are presented relative to reference materials that are similar, but not identical, and that are all slightly lighter than NIST SRM 3134. Our proposed data presentation allows a direct first-order comparison of almost all old data with future work while referring to an international measurement standard. In particular, canonical δ98/95Mo values such as +2.3‰ for seawater and −0.7‰ for marine Fe–Mn precipitates can be kept for discussion. As recent publications show that the ocean molybdenum isotope signature is homogeneous, the IAPSO ocean water standard or any other open ocean water sample is suggested as a secondary measurement standard, with a defined δ98/95Mo value of +2.34 ± 0.10‰ (2s). Les isotopes du molybdène (Mo) sont de plus en plus largement utilisés dans les sciences de la Terre. Ils sont principalement utilisés pour étudier l'oxygénation de l'océan et de l'atmosphère de la Terre. Cependant, de plus en plus de domaines d'application sont en cours de développement, tels que ceux concernant les processus magmatiques et hydrothermaux, les sciences planétaires ou encore le suivi de la pollution environnementale. Ici, nous présentons une proposition de présentation unifiée des rapports isotopiques du Mo dans les études du fractionnement isotopique dépendant de la masse. Nous suggérons que le δ98/95Mo du NIST SRM 3134 soit définit comme étant égal à +0.25 ‰. La raison est que la grande majorité des données publiées sont présentés par rapport à des matériaux de référence qui sont similaires, mais pas identiques, et qui sont tous légèrement plus léger que le NIST SRM 3134. Notre proposition de présentation des données permet une comparaison directe au premier ordre de presque toutes les anciennes données avec les travaux futurs en se référant à un standard international. En particulier, les valeurs canoniques du δ98/95Mo comme celle de +2,3 ‰ pour l'eau de mer et de -0,7 ‰ pour les précipités de Fe-Mn marins peuvent être conservés pour la discussion. Comme les publications récentes montrent que la signature isotopique moyenne du molybdène de l'océan est homogène, le standard de l'eau océanique IAPSO ou tout autre échantillon d'eau provenant de l'océan ouvert sont proposé comme standards secondaires, avec une valeur définie du δ98/95 Mo de 2.34 ± 0.10 ‰ (2s).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To test a new tiny-tipped intraoperative diagnostic tool that was designed to provide the surgeon with reliable stiffness data on the motion segment during microdiscectomy. A decrease in stiffness after nuclectomy and a measurable influence of muscle tension were assumed. If the influence of muscle tension on the motion segment could at least be ruled out, there should be no difference with regard to stiffness between women and men. If these criteria are met, this new intraoperative diagnostic tool could be used in further studies for objective decision-making regarding additional stabilization systems after microdiscectomy. METHODS: After evaluation of the influence of muscle relaxation during in vivo measurements with a spinal spreader between the spinous processes, 21 motion segments were investigated in 21 patients. Using a standardized protocol, including quantified muscle relaxation, spinal stiffness was measured before laminotomy and after nuclectomy. RESULTS: The decrease in stiffness after microdiscectomy was highly significant. There were no statistically significant differences between men and women. The average stiffness value before discectomy was 33.7 N/mm, and it decreased to 25.6 N/mm after discectomy. The average decrease in stiffness was 8.1 N/mm (24%). CONCLUSION: In the moderately degenerated spine, stiffness decreases significantly after microdiscectomy. Control for muscle relaxation is essential when measuring in vivo spinal stiffness. The new spinal spreader was found to provide reliable data. This spreader could be used in further studies for objective decision-making about additional stabilization systems after microdiscectomy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a measurement of the top quark pair () production charge asymmetry A (C) using 4.7 fb(-1) of proton-proton collisions at a centre-of-mass energy root s = 7 TeV collected by the ATLAS detector at the LHC. A -enriched sample of events with a single lepton (electron or muon), missing transverse momentum and at least four high transverse momentum jets, of which at least one is tagged as coming from a b-quark, is selected. A likelihood fit is used to reconstruct the event kinematics. A Bayesian unfolding procedure is employed to estimate A (C) at the parton-level. The measured value of the production charge asymmetry is A (C) = 0.006 +/- 0.010, where the uncertainty includes both the statistical and the systematic components. Differential A (C) measurements as a function of the invariant mass, the rapidity and the transverse momentum of the system are also presented. In addition, A (C) is measured for a subset of events with large velocity, where physics beyond the Standard Model could contribute. All measurements are consistent with the Standard Model predictions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Proteinuria (PTU) is an important marker for the development and progression of renal disease, cardiovascular disease and death, but there is limited information about the prevalence and factors associated with confirmed PTU in predominantly white European HIV+ persons, especially in those with an estimated glomerular filtration rate (eGFR) of 60 mL/min/1.73 m(2). PATIENTS AND METHODS Baseline was defined as the first of two consecutive dipstick urine protein (DPU) measurements during prospective follow-up >1/6/2011 (when systematic data collection began). PTU was defined as two consecutive DUP >1+ (>30 mg/dL) >3 months apart; persons with eGFR <60 at either DPU measurement were excluded. Logistic regression investigated factors associated with PTU. RESULTS A total of 1,640 persons were included, participants were mainly white (n=1,517, 92.5%), male (n=1296, 79.0%) and men having sex with men (n=809; 49.3%). Median age at baseline was 45 (IQR 37-52 years), and CD4 was 570 (IQR 406-760/mm(3)). The median baseline date was 2/12 (IQR 11/11-6/12), and median eGFR was 99 (IQR 88-109 mL/min/1.73 m(2)). Sixty-nine persons had PTU (4.2%, 95% CI 3.2-4.7%). Persons with diabetes had increased odds of PTU, as were those with a prior non-AIDS (1) or AIDS event and those with prior exposure to indinavir. Among females, those with a normal eGFR (>90) and those with prior abacavir use had lower odds of PTU (Figure 1). CONCLUSIONS One in 25 persons with eGFR>60 had confirmed proteinuria at baseline. Factors associated with PTU were similar to those associated with CKD. The lack of association with antiretrovirals, particularly tenofovir, may be due to the cross-sectional design of this study, and additional follow-up is required to address progression to PTU in those without PTU at baseline. It may also suggest other markers are needed to capture the deteriorating renal function associated with antiretrovirals may be needed at higher eGFRs. Our findings suggest PTU is an early marker for impaired renal function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Gender fair language use in job advertisements has been shown to impact the outcome of personnel selections. It is thus important to assess, to what extent gender fair language is used in job advertisements and with which factors it is associated, e.g., language, culture, status, and gender typicality of profession. Design/Methodology In the present research we investigated gender fair language use in job advertisements published online in four European countries with different socio-economic rankings of gender equality (World Economic Forum, 2011), namely Austria (rank 34), Czech Republic (75), Poland (42), and Switzerland (10). From four lines of business with different percentages of female employees – steels/metals, science, restaurants/food services, and health care –we randomly selected 100 job advertisements, summing up to 1600 job advertisements in total. Results A first analysis of the Swiss data indicates that the phrasing of job advertisements is closely related to a profession’s gender typicality (e.g., merely masculine forms are used in steels and metals, gender-fair forms in healthcare). Feminine forms however are almost never used. Cross-cultural comparisons will be presented. Limitations We analyzed job advertisements of four specific lines of business in four European countries. To what extend results can be generalized remains an open question. Research/Practical Implications The present data provide a sound basis for future studies on gender fair language use in job advertisements. Furthermore it sheds a light on how companies comply with national guidelines of gender equality. Originality/Value This is the first time that gender fair language use in job advertisements is investigated (a) across different countries and languages and (b) considering status and gender typicality of professions.