Resumo:
To determine the outcome of patients with brain metastasis (BM) from lung cancer treated with an external beam radiotherapy boost (RTB) after whole brain radiotherapy (WBRT).
Resumo:
Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors.
Resumo:
To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT).
Resumo:
PURPOSE External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). METHODS A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. RESULTS Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. CONCLUSIONS The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.
Resumo:
BACKGROUND: Papillary or follicular thyroid carcinomas exhibit a relatively benign course. Hence, long-term follow-up studies with well-defined disease stages and treatment details are needed to evaluate treatment strategies. METHODS: Patients who underwent complete resection of well-differentiated thyroid carcinoma (WDTC) confined to the thyroid gland between 1972 and 1990 identified from a prospective database were assessed. Follow-up was performed by interview, review of patient charts, and analysis of the Death Registry. Primary endpoints were overall survival (OS) and disease-specific survival (DSS). Review of histology was performed and extent of thyroid resection, postoperative therapy, and recognized prognostic factors but not lymphadenectomy were evaluated. RESULTS: Of 2,867 patients, 213 had complete resection of WDTC confined to the thyroid gland. Follow-up was completed in 166 patients with median age 54.2 (range, 20-85) years, and median follow-up of 27.2 (range, 15.6-34.5) years. The 10- and 20-year OS was 71 and 55%, respectively. DSS at 10 and 20 years was 81 and 69%, respectively, and correlated with age, histology, tumor size, radio-iodide ablation (RIA), and external beam irradiation (EBR) treatment. No patient died of WDTC more than 18 years after resection. Total or near-total thyroidectomy without lymphadenectomy was not superior to partial thyroidectomy. In multivariate analysis for DSS, age was the dominant factor, which correlated with histology. CONCLUSION: After a median follow-up of 27 years, about one-third of patients died of WDTC. Age, histology and postoperative therapy but not extent of thyroid resection determined DSS.
Resumo:
External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described.
Resumo:
Abstract Purpose: To further evaluate the use of microbeam irradiation (MBI) as a potential means of non-invasive brain tumor treatment by investigating the induction of a bystander effect in non-irradiated tissue. Methods: Adult rats were irradiated with 35 or 350 Gy at the European Synchotron Research Facility (ESRF), using homogenous (broad beam) irradiation (HI) or a high energy microbeam delivered to the right brain hemisphere only. The proteome of the frontal lobes were then analyzed using two-dimensional electrophoresis (2-DE) and mass spectrometry. Results: HI resulted in proteomic responses indicative of tumourigenesis; increased albumin, aconitase and triosphosphate isomerase (TPI), and decreased dihydrolipoyldehydrogenase (DLD). The MBI bystander effect proteomic changes were indicative of reactive oxygen species mediated apoptosis; reduced TPI, prohibitin and tubulin and increased glial fibrillary acidic protein (GFAP). These potentially anti-tumourigenic apoptotic proteomic changes are also associated with neurodegeneration. However the bystander effect also increased heat shock protein (HSP) 71 turnover. HSP 71 is known to protect against all of the neurological disorders characterized by the bystander effect proteome changes. Conclusions: These results indicate that the collective interaction of these MBI-induced bystander effect proteins and their mediation by HSP 71, may confer a protective effect which now warrants additional experimental attention.
Resumo:
The cyclotron laboratory for radioisotope production and multi-disciplinary research at the Bern University Hospital (Inselspital) is based on an 18-MeV proton accelerator, equipped with a specifically conceived 6-m long external beam line, ending in a separate bunker. This facility allows performing daily positron emission tomography (PET) radioisotope production and research activities running in parallel. Some of the latest developments on accelerator and detector physics are reported. They encompass novel detectors for beam monitoring and studies of low current beams.
Resumo:
Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management.
Resumo:
BACKGROUND AND PURPOSE: This is the first study investigating neoadjuvant interstitial high-dose-rate (HDR) brachytherapy combined with chemotherapy in patients with breast cancer. The goal was to evaluate the type of surgical treatment, histopathologic response, side effects, local control, and survival. PATIENTS AND METHODS: 53 patients, who could not be treated with breast-conserving surgery due to initial tumor size (36/53) or due to an unfavorable breast-tumor ratio (17/53), were analyzed retrospectively. All but one were in an intermediate/high-risk group (St. Gallen criteria). The patients received a neoadjuvant protocol consisting of systemic chemotherapy combined with fractionated HDR brachytherapy (2 x 5 Gy/day, total dose 30 Gy). In cases, where breast-conserving surgery was performed, patients received additional external-beam radiotherapy (EBRT, 1.8 Gy/day, total dose 50.4 Gy). In patients, who underwent mastectomy but showed an initial tumor size of T3/T4 and/or more than three infiltrated lymph nodes, EBRT was also performed. RESULTS: In 30/53 patients (56.6%) breast-conserving surgery could be performed. The overall histopathologic response rate was 96.2% with a complete remission in 28.3% of patients. 49/53 patients were evaluable for follow-up. After a median of 58 months (45-72 months), one patient showed a mild fibrosis of the breast tissue, three patients had mild to moderate lymphatic edema of the arm. 6/49 (12.2%) patients died of distant metastases, 4/49 (8.2%) were alive with disease, and 39/49 (79.6%) were free from disease. Local recurrence was observed in only one case (2%) 40 months after primary therapy. After mastectomy, this patient is currently free from disease. CONCLUSION: The combination of interstitial HDR brachytherapy and chemotherapy is a well-tolerated and effective neoadjuvant treatment in patients with breast cancer. Compared to EBRT, treatment time is short. Postoperative EBRT of the whole breast -- if necessary -- is still possible after neoadjuvant brachytherapy. Even though the number of patients does not permit definite conclusions, the results are promising regarding survival and the very low rate of local recurrences.
Resumo:
BACKGROUND AND PURPOSE: Analyses of permanent brachytherapy seed implants of the prostate have demonstrated that the use of a preplan may lead to a considerable decrease of dosimetric implant quality. The authors aimed to determine whether the same drawbacks of preplanning also apply to high-dose-rate (HDR) brachytherapy. PATIENTS AND METHODS: 15 patients who underwent two separate HDR brachytherapy implants in addition to external-beam radiation therapy for advanced prostate cancer were analyzed. A pretherapeutic transrectal ultrasound was performed in all patients to generate a preplan for the first brachytherapy implant. For the second brachytherapy, a subset of patients were treated by preplans based on the ultrasound from the first brachytherapy implant. Preplans were compared with the respective postplans assessing the following parameters: coverage index, minimum target dose, homogeneity index, and dose exposure of organs at risk. The prostate geometries (volume, width, height, length) were compared as well. RESULTS: At the first brachytherapy, the matching between the preplan and actual implant geometry was sufficient in 47% of the patients, and the preplan could be applied. The dosimetric implant quality decreased considerably: the mean coverage differed by -0.11, the mean minimum target dose by -0.15, the mean homogeneity index by -0.09. The exposure of organs at risk was not substantially altered. At the second brachytherapy, all patients could be treated by the preplan; the differences between the implant quality parameters were less pronounced. The changes of prostate geometry between preplans and postplans were considerable, the differences in volume ranging from -8.0 to 13.8 cm(3) and in dimensions (width, height, length) from -1.1 to 1.0 cm. CONCLUSION: Preplanning in HDR brachytherapy of the prostate is associated with a substantial decrease of dosimetric implant quality, when the preplan is based on a pretherapeutic ultrasound. The implant quality is less impaired in subsequent implants of fractionated brachytherapy.
Resumo:
In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.
Resumo:
PURPOSE: To report the clinical experience with external beam radiotherapy (RT) for AIDS-related lymphoma (ARL) with or without the involvement of the central nervous system (CNS) in HIV-infected patients. PATIENTS AND METHODS: Clinical outcome of 24 HIV-seropositive patients with ARL treated with RT from 1995 to 2004 was reviewed, testing factors associated with outcome. RESULTS: After 1 and 5 years, the overall survival was 65% and 35%, respectively. The mean RT dose was 31 Gy after normalization to fractions of daily 2 Gy (range, 7.8-47.2 Gy). Radiotherapy dose was associated with survival in univariate (P = .04) and multivariate analysis (P = .01). Other factors in univariate analysis associated with outcome were viral load (VL), highly active antiretroviral therapy (HAART), ARL stage, and CNS involvement. Patients with CNS involvement achieved complete response in 46% and improved clinical performance was seen in 73%. CONCLUSIONS: After chemotherapy, RT in combination with HAART is highly active, and RT should be encouraged especially after suboptimal responses to induction treatment.