11 resultados para Experimental results
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Purpose. For accurate resection of nonpalpable malignant breast lesions with a tumor-free resection rim, an exact and stable wire localization is essential. We tested the resistance towards traction force of different localization devices used in our clinic for breast lesions in two types of tissue. Materials and Methods. Eight different commercially available hook-wire devices were examined for resistance towards traction force using an analogue spring scale. Results. Most systems showed a high level of movement already under small traction force. Retractable systems with round hooks such as the Bard DuaLok , the Fil d'Ariane, and the RPLN Breast Localization Device withstood less traction force than the other systems. However, the Bard DuaLok system was very resistant towards a small traction force of 50 g when compared to the other systems. The Ultrawire Breast Localization Device withstood the most traction force in softer tissue and Kopans Breast Lesion Localization Needle withstood the most force in harder tissue. Conclusion. The Ultrawire Breast Localization Device and Kopans Breast Lesion Localization Needle withstood the most traction force. In general retractable systems withstand less traction force than nonretractable systems.
Resumo:
Gaining valid answers to so-called sensitive questions is an age-old problem in survey research. Various techniques have been developed to guarantee anonymity and minimize the respondent's feelings of jeopardy. Two such techniques are the randomized response technique (RRT) and the unmatched count technique (UCT). In this study we evaluate the effectiveness of different implementations of the RRT (using a forced-response design) in a computer-assisted setting and also compare the use of the RRT to that of the UCT. The techniques are evaluated according to various quality criteria, such as the prevalence estimates they provide, the ease of their use, and respondent trust in the techniques. Our results indicate that the RRTs are problematic with respect to several domains, such as the limited trust they inspire and non-response, and that the RRT estimates are unreliable due to a strong false "no" bias, especially for the more sensitive questions. The UCT, however, performed well compared to the RRTs on all the evaluated measures. The UCT estimates also had more face validity than the RRT estimates. We conclude that the UCT is a promising alternative to RRT in self-administered surveys and that future research should be directed towards evaluating and improving the technique.
Resumo:
Gaining valid answers to so-called sensitive questions is an age-old problem in survey research. Various techniques have been developed to guarantee anonymity and minimize the respondent's feelings of jeopardy. Two such techniques are the randomized response technique (RRT) and the unmatched count technique (UCT). In this study we evaluate the effectiveness of different implementations of the RRT (using a forced-response design) in a computer-assisted setting and also compare the use of the RRT to that of the UCT. The techniques are evaluated according to various quality criteria, such as the prevalence estimates they provide, the ease of their use, and respondent trust in the techniques. Our results indicate that the RRTs are problematic with respect to several domains, such as the limited trust they inspire and non-response, and that the RRT estimates are unreliable due to a strong false "no" bias, especially for the more sensitive questions. The UCT, however, performed well compared to the RRTs on all the evaluated measures. The UCT estimates also had more face validity than the RRT estimates. We conclude that the UCT is a promising alternative to RRT in self-administered surveys and that future research should be directed towards evaluating and improving the technique.
Resumo:
Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. Therefore, a combined experimental and analytical study was performed to address these open questions. A quasi-static mechanical compression test was performed to compare the initial mechanical properties of PEEK-OPTIMA polymer in a dry, room-temperature and in an aqueous, 37 degrees C environment (n=10 per group). The creep behaviour of cylindrical PEEK polymer specimens (n=6) was measured in a simulated physiological environment at an applied stress level of 10 MPa for a loading duration of 2000 hours (12 weeks). To compare the biomechanical performance of different intervertebral cage types made from PEEK and titanium under complex loading conditions, a three-dimensional finite element model of a functional spinal unit was created. The elastic modulus of PEEK polymer specimens in a physiological environment was 1.8% lower than that of specimens tested at dry, room temperature conditions (P<0.001). The results from the creep test showed an average creep strain of less than 0.1% after 2000 hours of loading. The finite element analysis demonstrated high strain and stress concentrations at the bone/implant interface, emphasizing the importance of cage geometry for load distribution. The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.
Resumo:
Employing a scanning tunneling microscopy based beak junction technique and mechanically controlled break junction experiments, we investigated tolane (diphenylacetylene)-type single molecular junctions having four different anchoring groups (SH, pyridyl (PY), NH2, and CN) at a solid/liquid interface. The combination of current–distance and current–voltage measurements and their quantitative statistical analysis revealed the following sequence for junction formation probability and stability: PY > SH > NH2 > CN. For all single molecular junctions investigated, we observed the evolution through multiple junction configurations, with a particularly well-defined binding geometry for PY. The comparison of density functional theory type model calculations and molecular dynamics simulations with the experimental results revealed structure and mechanistic details of the evolution of the different types of (single) molecular junctions upon stretching quantitatively.
Resumo:
Lesions of the ventromedial prefrontal cortex can result in a deficient decision-making behavior. So far, most experimental results in the neuropsychological decision-making research have been obtained with gambling tasks. Due to their high complexity, it is difficult to evaluate the underlying processes of the decision-making deficits. The aim of this study was to assess if patients with ventromedial prefrontal damage compared to patients with dorsolateral prefrontal damage and controls show a deficit in an early stage of the decision-making process. Nine patients with ventromedial prefrontal damage, three with dorsolateral prefrontal damage, and eleven healthy controls were tested with a newly developed decision task in which they had to search actively for the information they needed for their decisions. Our results show that patients with ventromedial prefrontal damage compared to the brain-lesioned dorsolateral prefrontal control group and healthy controls searched less for information with regard to risk defusing operators or consequences of their decisions indicating impairment already in the early stage of the decision-making process.
Resumo:
Spreading the PSF over a quite large amount of pixels is an increasingly used observing technique in order to reach extremely precise photometry, such as in the case of exoplanets searching and characterization via transits observations. A PSF top-hat profile helps to minimize the errors contribution due to the uncertainty on the knowledge of the detector flat field. This work has been carried out during the recent design study in the framework of the ESA small mission CHEOPS. Because of lack of perfect flat-fielding information, in the CHEOPS optics it is required to spread the light of a source into a well defined angular area, in a manner as uniform as possible. Furthermore this should be accomplished still retaining the features of a true focal plane onto the detector. In this way, for instance, the angular displacement on the focal plane is fully retained and in case of several stars in a field these look as separated as their distance is larger than the spreading size. An obvious way is to apply a defocus, while the presence of an intermediate pupil plane in the Back End Optics makes attractive to introduce here an optical device that is able to spread the light in a well defined manner, still retaining the direction of the chief ray hitting it. This can be accomplished through an holographic diffuser or through a lenslet array. Both techniques implement the concept of segmenting the pupil into several sub-zones where light is spread to a well defined angle. We present experimental results on how to deliver such PSF profile by mean of holographic diffuser and lenslet array. Both the devices are located in an intermediate pupil plane of a properly scaled laboratory setup mimicking the CHEOPS optical design configuration. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.