43 resultados para Experimental Performance

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper deals with scheduling batch (i.e., discontinuous), continuous, and semicontinuous production in process industries (e.g., chemical, pharmaceutical, or metal casting industries) where intermediate storage facilities and renewable resources (processing units and manpower) of limited capacity have to be observed. First, different storage configurations typical of process industries are discussed. Second, a basic scheduling problem covering the three above production modes is presented. Third, (exact and truncated) branch-and-bound methods for the basic scheduling problem and the special case of batch scheduling are proposed and subjected to an experimental performance analysis. The solution approach presented is flexible and in principle simple, and it can (approximately) solve relatively large problem instances with sufficient accuracy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In sport psychology research about emotional contagion in sport teams has been scarce (Reicherts & Horn, 2008). Emotional contagion is a process leading to a specific emotional state in an individual caused by the perception of another individual’s emotional expression (Hatfield, Cacioppo & Rapson, 1994). Apitzsch (2009) described emotional contagion as one reason for collapsing sport teams. The present study examined the occurrence of emotional contagion in dyads during a basketball task and the impact of a socially induced emotional state on performance. An experiment with between-subjects design was conducted. Participants (N=81, ♀=38, M=21.33 years, SD=1.45) were randomly assigned to one of two experimental conditions, by joining a confederate to compose a same gender, ad hoc team. The team was instructed to perform a basketball task as quickly as possible. The between-factor of the experimental design was the confederate’s emotional expression (positive or negative valence). The within-factor was participants’ emotional state, measured pre- and post-experimentally using PANAS (Krohne, Egloff, Kohlmann & Tausch, 1996). The basketball task was video-taped and the number of frames participants needed to complete the task was used to determine the individual performance. The confederate’s emotional expression was appraised in a significantly different manner across both experimental conditions by participants and video raters (MC). Mixed between-within subjects ANOVAs were conducted to examine the impact of the two conditions on participants’ scores on the PANAS subscales across two time periods (pre- and post-experimental). No significant interaction effects but substantial main effects for time were found on both PANAS subscales. Both groups showed an increase in positive and a reduction in negative PANAS scores across these two time periods. Nevertheless, video raters assessment of the emotional states expressed by participants was significantly different between the positive (M=3.23, SD=0.45) and negative condition (M=2.39, SD=0.53; t=7.64, p<.001, eta squared=.43). An independent-samples t-test indicated no difference in performance between conditions. Furthermore, no significant correlation between the extent of positive or negative emotional contagion and the number of frames was observed. The basketball task lead to an improvement of the emotional state of participants, independently of the condition. Even though participants PANAS scores indicated a tendency to emotional contagion, it was not statistically significant. This could be explained by the low task duration of approximately three minutes. Moreover, the performance of participants was unaffected by the experimental condition or the extent of positive or negative emotional contagion. Apitzsch, E. (2009). A case study of a collapsing handball team. In S. Jern & J. Näslund (Eds.), Dynamics within and outside the lab. Proceedings from The 6th Nordic Conference on Group and Social Psychology, May 2008, Lund, pp. 35-52. Hatfield, E., Cacioppo, J. T. & Rapson, R. L. (1994). Emotional contagion. Cambridge: University Press. Krohne, H. W., Egloff, B., Kohlmann, C.-W. & Tausch, A. (1996). Untersuchungen mit einer deutschen Version der „Positive und Negative Affect Schedule“ (PANAS). Diagnostica, 42 (2), 139-156. Reicherts, M. & Horn, A. B. (2008). Emotionen im Sport. In W. Schlicht & B. Strauss (Eds.), Enzyklopädie der Psychologie. Grundlagen der Sportpsychologie (Bd. 1) (S. 563-633). Göttingen: Hogrefe.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Budgets are often simultaneously used for the conflicting purposes of planning and performance evaluation. While economic theory suggests that firms should use separate budgets for conflicting purposes this contrasts with existing evidence that firms rarely do so. We address two open questions related to these observations in an experiment. Specifically, we investigate how a planning task that is in conflict with the performance evaluation task affects behavior in budget negotiations and their outcomes. Additionally, we analyze whether a single budget can be effectively used for both purposes compared to two separate budgets. We develop theory to predict that adding a planning task that is in conflict with the superior’s performance evaluation task increases the subordinate’s cooperation in and after the negotiation of a performance evaluation budget. Moreover, we predict that subordinate cooperation increases even more when the superior is restricted to use a single budget for both purposes. Our results broadly support our hypotheses. Specifically, we find that when budgets are used for both planning and performance evaluation, this increases the subordinate’s budget proposals during the negotiation and his performance after the negotiation. These effects tend to be even larger when the superior is restricted to a single budget rather than separate budgets for planning and performance evaluation, particularly with respect to subordinate performance. In our experimental setting, the benefits of increased subordinate cooperation even more than offset the loss in flexibility from the superior’s restriction to a single budget. The results of this study add to the understanding of the interdependencies of conflicting budgeting purposes and contribute to explain why firms often use a single budget for multiple purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Next to the extensive use of social networking platforms (SNPs) for communication and relationship building with friends and relatives, SNPs are also increasingly used for enhancing collaboration at work. SNP usage at the workplace is fundamentally different and it is unclear how SNPs can improve collaboration as well as in what way their designs should be modified and adapted to collaboration settings. This research identifies specific SNP functions that enhance social presence as particularly beneficial for collaboration. Consequently, two designs of SNPs, one with high social presence and one with low social presence, are outlined and its impacts on collaboration are discussed. A framework is constructed that illustrates how social presence in SNPs can improve team performance through enhancing transactive memory within teams (intra-group collaboration) and relational capital across teams (inter-group collaboration). In addition, it is outlined how this framework could be evaluated in an experimental setting of teams working on a complex group task.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated (1) the micromorphology by scanning electron microscopy (SEM) and (2) the adhesive performance by microtensile bond strength (μTBS) of diamond bur-treated dentin compared to Er:YAG laser-treated dentin of human primary teeth. (1) For qualitative SEM evaluation, dentin of 18 second primary molars (n = 3/method) was treated with either diamond bur as a control (group 1a: 40 μm diamond bur only (clinical situation); group 1b: grinding + 40 μm diamond bur) or with Er:YAG laser (group 2a (clinical situation, manufacturer's settings): 200 mJ/25 Hz (5 W) + 100 mJ/35 Hz (3.5 W) laser only; group 2b (experimental setting "high"): grinding + 400 mJ/20 Hz (8 W); group 2c (manufacturer's setting "finishing"): grinding + 100 mJ/35 Hz (3.5 W); group 2d (experimental setting "low"): grinding + 50 mJ/35 Hz (1.75 W)). (2) For evaluation of adhesive performance, 64 second primary molars were divided into four groups and treated as described for group 1b and groups 2b/c/d (n = 16/method), and μTBS of Clearfil SE/Clearfil Majesty Esthetic to dentin was measured. The SEM micrographs were qualitatively analyzed. The μTBS values were compared with a Kruskal-Wallis test. The significance level was set at α = 0.05. SEM micrographs showed the typical micromorphologies with a smear layer for the diamond bur groups and open dentin tubules for all laser-treated groups. However, in group 2d, the laser beam had insufficiently irradiated the dentin area, rendering the underlying ground surface partly visible. There were no statistically significant differences between μTBS values of the four groups (p = 0.394). This suggests that Er:YAG laser treatment of dentin of primary molars provides bond strengths similar to those obtained following diamond bur treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Currently, several new stent retriever devices for acute stroke treatment are under development and early clinical evaluation. Preclinical testing under standardized conditions is an important first step to evaluate the technical performance and potential of these devices. The aim of this study was to evaluate the immediate recanalization effect, recanalization efficacy, thrombus-device interaction, and safety of a new stent retriever intended for thrombectomy in patients with acute stroke. MATERIAL AND METHODS: The pREset thrombectomy device (4 × 20 mm) was evaluated in 16 vessel occlusions in an established swine model. Radiopaque thrombi (10-mm length) were used for visualization of thrombus-device interaction during application and retrieval. Flow-restoration effect immediately after deployment and after 5-minute embedding time before retrieval, recanalization rate after retrieval, thromboembolic events, and complications were assessed. High-resolution FPCT was performed to illustrate thrombus-device interaction during the embedding time. RESULTS: Immediate flow restoration was achieved in 75% of occlusions. An increase or stable percentage of recanalizations during embedding time before retrieval was seen in 56.3%; a decrease, in 12.5%; reocclusion of a previously recanalized vessel, in 18.8%; and no recanalization effect at all, in 12.5%. Complete recanalization (TICI 3) after retrieval was achieved in 93.8%; partial recanalization (TICI 2b), in 6.2%. No distal thromboembolic events were observed. High-resolution FPCT illustrated entrapment of the thrombus between the stent struts and compression against the contralateral vessel wall, leading to partial flow restoration. During retrieval, the thrombus was retained in a straight position within the stent struts. CONCLUSIONS: In this experimental study, the pREset thrombus retriever showed a high recanalization rate in vivo. High-resolution FPCT allows detailed illustration of the thrombus-device interaction during embedding time and is advocated as an add-on tool to the animal model used in this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the effects of different dietary vitamin D regimen on selected blood parameters in laying hens. Supplementation with vitamin D-3 only was compared with a combination of vitamin D-3 and its metabolite 25-hydroxy-cholecalciferol (25(OH)D-3). Blood concentrations of total calcium, phosphate and 25 (OH)D-3 were determined. Four thousand one-day-old LSL chicks were split in two treatment groups and distributed to eight pens. The control group was given a commercial animal diet containing 2800 IU synthetic vitamin D-3 in the starter feed and 2000 IU synthetic vitamin D-3 in the pullet feed. The experimental group was fed the same commercial diet in which half the synthetic vitamin D-3 content had been substituted with 25(OH)D-3 (Hy center dot D (R)). At 18 weeks of age, pullets were transferred to the layer house. At the ages of 11, 18 and 34 weeks, between 120 and 160 blood samples were collected from both the control and the experimental groups, respectively. The experimental group had higher levels of 25 (OH)D-3 than the control group at all three ages. Serum calcium levels did not differ between the treatment groups at any age. With the onset of laying, calcium levels rose significantly. Whereas blood serum concentration at 18 weeks was 3 mmol/L in both treatment groups, it increased to 8.32 mmol/L in the control group and to 8.66 mmol/L in the experimental group at week 34. At weeks 11 and 34, phosphate was significantly lower in the experimental group. In conclusion, HyD (R) significantly affected serum phosphate and 25(OH)D-3 levels. No effects of (25(OH)D-3 supplementation on performance, shell quality and fractures of keelbones were found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The resting and maximum in situ cardiac performance of Newfoundland Atlantic cod (Gadus morhua) acclimated to 10, 4 and 0°C were measured at their respective acclimation temperatures, and when acutely exposed to temperature changes: i.e. hearts from 10°C fish cooled to 4°C, and hearts from 4°C fish measured at 10 and 0°C. Intrinsic heart rate (f(H)) decreased from 41 beats min(-1) at 10°C to 33 beats min(-1) at 4°C and 25 beats min(-1) at 0°C. However, this degree of thermal dependency was not reflected in maximal cardiac output (Q(max) values were ~44, ~37 and ~34 ml min(-1) kg(-1) at 10, 4 and 0°C, respectively). Further, cardiac scope showed a slight positive compensation between 4 and 0°C (Q(10)=1.7), and full, if not a slight over compensation between 10 and 4°C (Q(10)=0.9). The maximal performance of hearts exposed to an acute decrease in temperature (i.e. from 10 to 4°C and 4 to 0°C) was comparable to that measured for hearts from 4°C- and 0°C-acclimated fish, respectively. In contrast, 4°C-acclimated hearts significantly out-performed 10°C-acclimated hearts when tested at a common temperature of 10°C (in terms of both Q(max) and power output). Only minimal differences in cardiac function were seen between hearts stimulated with basal (5 nmol l(-1)) versus maximal (200 nmol l(-1)) levels of adrenaline, the effects of which were not temperature dependent. These results: (1) show that maximum performance of the isolated cod heart is not compromised by exposure to cold temperatures; and (2) support data from other studies, which show that, in contrast to salmonids, cod cardiac performance/myocardial contractility is not dependent upon humoral adrenergic stimulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the appearance of downsized and simplified TCP/IP stacks, single nodes from Wireless Sensor Networks (WSNs) have become directly accessible from the Internet with commonly used networking tools and applications (e.g., Telnet or SMTP). However, TCP has been shown to perform poorly in wireless networks, especially across multiple wireless hops. This paper examines TCP performance optimizations based on distributed caching and local retransmission strategies of intermediate nodes in a TCP connection, and proposes extended techniques to these strategies. The paper studies the impact of different radio duty-cycling MAC protocols on the end-to-end TCP performance when using the proposed TCP optimization strategies in an extensive experimental evaluation on a real-world sensor network testbed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. Therefore, a combined experimental and analytical study was performed to address these open questions. A quasi-static mechanical compression test was performed to compare the initial mechanical properties of PEEK-OPTIMA polymer in a dry, room-temperature and in an aqueous, 37 degrees C environment (n=10 per group). The creep behaviour of cylindrical PEEK polymer specimens (n=6) was measured in a simulated physiological environment at an applied stress level of 10 MPa for a loading duration of 2000 hours (12 weeks). To compare the biomechanical performance of different intervertebral cage types made from PEEK and titanium under complex loading conditions, a three-dimensional finite element model of a functional spinal unit was created. The elastic modulus of PEEK polymer specimens in a physiological environment was 1.8% lower than that of specimens tested at dry, room temperature conditions (P<0.001). The results from the creep test showed an average creep strain of less than 0.1% after 2000 hours of loading. The finite element analysis demonstrated high strain and stress concentrations at the bone/implant interface, emphasizing the importance of cage geometry for load distribution. The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.