11 resultados para Excellent performance
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Evaluation and validation of the psychometric properties of the eight-item modified Medical Outcomes Study Social Support Survey (mMOS-SS).
Resumo:
Objectives: In fast ball sports like beach volleyball, decision-making skills are a determining factor for excellent performance. The current investigation aimed to identify factors that influence the decisionmaking process in top-level beach volleyball defense in order to find relevant aspects for further research. For this reason, focused interviews with top players in international beach volleyball were conducted and analyzed with respect to decision-making characteristics. Design: Nineteen world-tour beach volleyball defense players, including seven Olympic or world champions, were interviewed, focusing on decision-making factors, gaze behavior, and interactions between the two. Methods: Verbal data were analyzed by inductive content analysis according to Mayring (2008). This approach allows categories to emerge from the interview material itself instead of forcing data into preset classifications and theoretical concepts. Results: The data analysis showed that, for top-level beach volleyball defense, decision making depends on opponent specifics, external context, situational context, opponent's movements, and intuition. Information on gaze patterns and visual cues revealed general tendencies indicating optimal gaze strategies that support excellent decision making. Furthermore, the analysis highlighted interactions between gaze behavior, visual information, and domain-specific knowledge. Conclusions: The present findings provide information on visual perception, domain-specific knowledge, and interactions between the two that are relevant for decision making in top-level beach volleyball defense. The results can be used to inform sports practice and to further untangle relevant mechanisms underlying decision making in complex game situations.
Resumo:
Manual counting of bacterial colony forming units (CFUs) on agar plates is laborious and error-prone. We therefore implemented a colony counting system with a novel segmentation algorithm to discriminate bacterial colonies from blood and other agar plates.A colony counter hardware was designed and a novel segmentation algorithm was written in MATLAB. In brief, pre-processing with Top-Hat-filtering to obtain a uniform background was followed by the segmentation step, during which the colony images were extracted from the blood agar and individual colonies were separated. A Bayes classifier was then applied to count the final number of bacterial colonies as some of the colonies could still be concatenated to form larger groups. To assess accuracy and performance of the colony counter, we tested automated colony counting of different agar plates with known CFU numbers of S. pneumoniae, P. aeruginosa and M. catarrhalis and showed excellent performance.
Resumo:
The purpose of our study was to assess physical and emotional factors in heart transplant patients. A prospective design was used to compare patients' physical symptoms, emotional complaints, and restrictions at admission to the waiting list, immediately after, and 1 and 5 years after heart transplantation. Thirty-three patients were included (30 male, 3 female) in the study. Their mean age at admission was 48 +/- 10.2 years. Of these, 23 suffered from cardiomyopathy, 8 from coronary heart disease, and 2 from valvular insufficiency. At admission, the patients suffered from symptoms of cardiac insufficiency, and were restricted in sports, gardening, hobbies, sexual life, job, food-intake, and mobility. More than three-fourths rated their physical and emotional status as moderate to poor. Emotionally, they suffered from irritability, restlessness, depression, psychic lability, lowered drive, lack of social contact, low self-esteem, and anxiety. At the end of rehabilitation (4-8 weeks after the operation), all physical and emotional complaints, as well as restrictions had significantly decreased (p < 0.0001 to p < 0.001), except for trembling, numbness of hands/feet, and food-intake. One year postoperatively, patients reported even fewer physical complaints (p < 0.01). Three-fourths rated their physical and emotional status good or excellent. Five years postoperatively--in contrast to physical status, restrictions, and physical complaints--the emotional complaints had increased significantly (p < 0.0001). Patients reported excellent physical performance up to 5 years postoperatively. On the other hand, the study revealed that their emotional well-being had significantly deteriorated from 1 to 5 years postoperatively. Attention should, therefore, not only be paid to the good physical health of the survivors, but also to the worsening of their emotional status.
Resumo:
OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.
Resumo:
The aim of this study was to compare the performance of the DIAGNOdent 2095 with visual examination for occlusal caries detection in permanent and primary molars. The sample comprised 148 permanent human molars and 179 primary human molars. The samples were measured and visually examined three times by two examiners. After measurement, the teeth were histologically prepared and assessed for caries extension. Sensitivity, specificity, accuracy and area under the receiver operating characteristics (ROC) curve were calculated. Intra-class correlation (ICC), unweighted kappa and the Bland and Altman method were used to assess inter- and intra-examiner reproducibility. DIAGNOdent showed higher specificity and lower sensitivity than did visual examination. The ICC values indicated an excellent agreement between the examinations. Kappa values varied from good to excellent for DIAGNOdent but from poor to good for visual examination. In conclusion, the DIAGNOdent may be a useful adjunct to conventional methods for occlusal caries detection.
Resumo:
Recently, screening tests for monitoring the prevalence of transmissible spongiform encephalopathies specifically in sheep and goats became available. Although most countries require comprehensive test validation prior to approval, little is known about their performance under normal operating conditions. Switzerland was one of the first countries to implement 2 of these tests, an enzyme-linked immunosorbent assay (ELISA) and a Western blot, in a 1-year active surveillance program. Slaughtered animals (n = 32,777) were analyzed in either of the 2 tests with immunohistochemistry for confirmation of initial reactive results, and fallen stock samples (n = 3,193) were subjected to both screening tests and immunohistochemistry in parallel. Initial reactive and false-positive rates were recorded over time. Both tests revealed an excellent diagnostic specificity (>99.5%). However, initial reactive rates were elevated at the beginning of the program but dropped to levels below 1% with routine and enhanced staff training. Only those in the ELISA increased again in the second half of the program and correlated with the degree of tissue autolysis in the fallen stock samples. It is noteworthy that the Western blot missed 1 of the 3 atypical scrapie cases in the fallen stock, indicating potential differences in the diagnostic sensitivities between the 2 screening tests. However, an estimation of the diagnostic sensitivity for both tests on field samples remained difficult due to the low disease prevalence. Taken together, these results highlight the importance of staff training, sample quality, and interlaboratory comparison trials when such screening tests are implemented in the field.
Resumo:
This study aimed to assess the performance of International Caries Detection and Assessment System (ICDAS), radiographic examination, and fluorescence-based methods for detecting occlusal caries in primary teeth. One occlusal site on each of 79 primary molars was assessed twice by two examiners using ICDAS, bitewing radiography (BW), DIAGNOdent 2095 (LF), DIAGNOdent 2190 (LFpen), and VistaProof fluorescence camera (FC). The teeth were histologically prepared and assessed for caries extent. Optimal cutoff limits were calculated for LF, LFpen, and FC. At the D (1) threshold (enamel and dentin lesions), ICDAS and FC presented higher sensitivity values (0.75 and 0.73, respectively), while BW showed higher specificity (1.00). At the D (2) threshold (inner enamel and dentin lesions), ICDAS presented higher sensitivity (0.83) and statistically significantly lower specificity (0.70). At the D(3) threshold (dentin lesions), LFpen and FC showed higher sensitivity (1.00 and 0.91, respectively), while higher specificity was presented by FC (0.95), ICDAS (0.94), BW (0.94), and LF (0.92). The area under the receiver operating characteristic (ROC) curve (Az) varied from 0.780 (BW) to 0.941 (LF). Spearman correlation coefficients with histology were 0.72 (ICDAS), 0.64 (BW), 0.71 (LF), 0.65 (LFpen), and 0.74 (FC). Inter- and intraexaminer intraclass correlation values varied from 0.772 to 0.963 and unweighted kappa values ranged from 0.462 to 0.750. In conclusion, ICDAS and FC exhibited better accuracy in detecting enamel and dentin caries lesions, whereas ICDAS, LF, LFpen, and FC were more appropriate for detecting dentin lesions on occlusal surfaces in primary teeth, with no statistically significant difference among them. All methods presented good to excellent reproducibility.
Resumo:
BackgroundThe aim of the present study was to evaluate the feasibility of using a telephone survey in gaining an understanding of the possible herd and management factors influencing the performance (i.e. safety and efficacy) of a vaccine against porcine circovirus type 2 (PCV2) in a large number of herds and to estimate customers¿ satisfaction.ResultsDatasets from 227 pig herds that currently applied or have applied a PCV2 vaccine were analysed. Since 1-, 2- and 3-site production systems were surveyed, the herds were allocated in one of two subsets, where only applicable variables out of 180 were analysed. Group 1 was comprised of herds with sows, suckling pigs and nursery pigs, whereas herds in Group 2 in all cases kept fattening pigs. Overall 14 variables evaluating the subjective satisfaction with one particular PCV2 vaccine were comingled to an abstract dependent variable for further models, which was characterized by a binary outcome from a cluster analysis: good/excellent satisfaction (green cluster) and moderate satisfaction (red cluster). The other 166 variables comprised information about diagnostics, vaccination, housing, management, were considered as independent variables. In Group 1, herds using the vaccine due to recognised PCV2 related health problems (wasting, mortality or porcine dermatitis and nephropathy syndrome) had a 2.4-fold increased chance (1/OR) of belonging to the green cluster. In the final model for Group 1, the diagnosis of diseases other than PCV2, the reason for vaccine administration being other than PCV2-associated diseases and using a single injection of iron had significant influence on allocating into the green cluster (P¿<¿0.05). In Group 2, only unchanged time or delay of time of vaccination influenced the satisfaction (P¿<¿0.05).ConclusionThe methodology and statistical approach used in this study were feasible to scientifically assess ¿satisfaction¿, and to determine factors influencing farmers¿ and vets¿ opinion about the safety and efficacy of a new vaccine.
Resumo:
OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.
Resumo:
BACKGROUND Hepatitis B viruses (HBV) harboring mutations in the a-determinant of the Hepatitis B surface antigen (HBsAg) are associated with reduced reactivity of HBsAg assays. OBJECTIVES To evaluate the sensitivity and specificity of three HBsAg point-of-care tests for the detection of HBsAg of viruses harboring HBsAg mutations. STUDY DESIGN A selection of 50 clinical plasma samples containing HBV with HBsAg mutations was used to evaluate the performance of three HBsAg point-of-care tests (Vikia(®), bioMérieux, Marcy-L'Étoile, France. Alere Determine HBsAg™, Iverness Biomedical Innovations, Köln, Germany. Quick Profile™, LumiQuick Diagnostics, California, USA) and compared to the ARCHITECT HBsAg Qualitative(®) assay (Abbott Laboratories, Sligo, Ireland). RESULTS The sensitivity of the point-of-care tests ranged from 98% to 100%. The only false-negative result occurred using the Quick Profile™ assay with a virus harboring a D144A mutation. CONCLUSIONS The evaluated point-of-care tests revealed an excellent sensitivity in detecting HBV samples harboring HBsAg mutations.