12 resultados para Evaluation Reports
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We examine the impact of identity preferences on the interrelation between incentives and performance measurement. In our model, a manager identifies with an organization and loses utility to the extent that his actions conflict with effort-standards issued by the principal. Contrary to prior arguments in the literature, we find conditions under which a manager who identifies strongly with the organization receives stronger incentives and faces more performance evaluation reports than a manager who does not identify with the organization. Our theory predicts that managers who experience events that boost their identification with the firm can decrease their effort in short-term value creation. We also find that firms are more likely to employ less precise but more congruent performance measures, such as stock prices, when contracting with managers who identify little with the organization. In contrast, they use more precise but less congruent measures, such as accounting earnings, when contracting with managers who identify strongly with the firm.
Resumo:
Clinical forensic examinations of children suspected of having been sexually abused are increasingly part of the routine of medicolegal institutes. The findings collected from 2005 until 2007 at the Institute of Legal Medicine of the Hanover Medical School were analysed retrospectively. Altogether, 91 children (74 females, 17 males, mean age 8.7 years) were examined. In 87.9% of the cases, the examination had been ordered by the police. In 73.6%, the victim knew the suspected perpetrator well or he was a family member. 40.7% of the children were seen within 72 hours after the alleged abuse. 12.1% of the children had extragenital lesions. In 27% of the victims, marked anogenital injuries were found, which were characteristic of sexual abuse in 9%. In 18 cases (20.2%), swabs were taken for spermatozoa detection. 3 of 17 vaginal smears showed positive test results for sperm up to 21 hours after the incident. No spermatozoa could be detected in 4 anal and 2 oral swabs as well as in one swab taken from the skin of the victim's thigh. In summary, the evaluation shows that early clinical forensic examination of children suspected of having been sexually abused is crucial to document evidence that is highly significant for the investigation and court proceedings. Often suspected sexual child abuse cannot be proved by medical findings alone. Of course, the absence of anogenital injuries does nor rule out sexual abuse.
Resumo:
Medical-forensic examination of sexual assault victims and alleged offenders is a common task of many forensic institutes. In the current study, the results from samples taken at the Institute of Legal Medicine, Hanover Medical School, during a period from 2005 to 2007 were retrospectively evaluated. In total, 292 victims (283 females and nine males) and 88 suspects were examined. At the time of the assault, 41.8% of the victims and 43.2% of the alleged perpetrators were under the influence of alcohol. Injuries were found in 84.9% of the victims and 39.8% of the suspects. Thirty victims (10.3%) reported having been choked or strangled. Cytology was performed in 218 victims. In 81 cases (38.0%), sperm could be detected in vaginal swabs up to 3 days post-assault. In seven (18.9%) out of 37 anal samples, evidence of sperm could be found 24 h post-assault. None of 22 oral samples was positive for sperm. Out of 301 sexual assault cases, 171 could be proved by means of medical-forensic examination. In summary, our evaluation shows that an early medical-forensic examination of both victim and suspect can secure numerous medical findings. Furthermore, persons intoxicated by alcohol, handicapped persons and persons with psychiatric disorders are more vulnerable to become a sexual assault victim.
Resumo:
Excessive cantilever lengths of fixed implant-supported prostheses may have functional and biomechanical disadvantages. This study reports the clinical outcomes of unconventional implants placed for distal support of a fixed implant-supported prostheses. Seven extraoral implants with intraosseous lengths of 2.5 to 4.0 mm were placed in four patients. Distal cantilevers had a mean length of 29.8 mm (range, 18.6 to 39.3 mm). No bone loss or other adverse events were found. The prosthetic plan was maintained in all patients. Within the limits of the employed research design, this concept seems to be a successful option for fixed complete implant-supported prosthesis treatment.
Resumo:
In a retrospective cohort study undertaken in 12 European countries, 249 female narcoleptic patients with cataplexy (n = 216) and without cataplexy (n = 33) completed a self-administrated questionnaire regarding pregnancy and childbirth. The cohort was divided further into patients whose symptoms of narcolepsy started before or during pregnancy (308 pregnancies) and those in whom the first symptoms of narcolepsy appeared after delivery (106 pregnancies). Patients with narcolepsy during pregnancy were older during their first pregnancy (P < 0.001) and had a higher body mass index (BMI) prior to pregnancy (P < 0.01). Weight gain during pregnancy was higher in narcoleptic patients with cataplexy (P < 0.01). More patients with narcolepsy-cataplexy during pregnancy had impaired glucose metabolism and anaemia. Three patients experienced cataplexy during delivery. The rate of caesarean sections was higher in the narcolepsy-cataplexy group compared to the narcolepsy group (P < 0.05). The mean birth weight and gestational age of neonates were within the normal range and did not differ across groups. Neonatal care was affected adversely by symptoms of narcolepsy in 60.1% of those with narcolepsy during pregnancy. This study reports more obstetric complications in patients with narcolepsy-cataplexy during pregnancy; however, these were not severe. This group also had a higher BMI and higher incidence of impaired glucose metabolism during pregnancy. Caesarian section was conducted more frequently in narcolepsy-cataplexy patients, despite cataplexy being a rare event during delivery. Furthermore, symptoms of narcolepsy may render care of the infant more difficult.
Resumo:
This study reports on 15 mandibular reconstructions using the Dumbach Titan Mesh-System and particulate cancellous bone and marrow harvested from bilateral posterior ilia. All cases showed segmental defects. Eleven cases involved patients with malignant tumor. Six patients had received irradiation of 40-50 Gy. Reconstructions were performed immediately in 1 patient and secondarily in the remaining 14 patients. In 13 cases, mandibles were successfully reconstructed. Of these 13 patients, 9 reconstructions were completed without complications, whereas the other 4 cases showed complications. In 2 cases, reconstruction failed completely. Overall success rate was 87%. Statistical analysis revealed the extent of mandibular defect, but not malignancy of the original disease or radiotherapy of
Resumo:
OBJECTIVES: The C-Port System (Cardica, Inc, Redwood City, Calif) integrates in one tool all functions necessary to enable rapid automated distal coronary anastomoses. The goal of this prospective, nonrandomized, and multicenter study is to determine the safety and efficacy of this novel anastomotic system. METHODS: Five centers enrolled 133 patients awaiting elective coronary artery bypass grafting surgery. Outcome variables were intraoperative device performance, incidence of device-related adverse events, predischarge and 6-month angiographic graft patency, and 12-month clinical outcome. Independent core laboratories performed qualitative and quantitative angiographic and computed tomographic assessments. RESULTS: The C-Port was used to perform a vein-to-coronary anastomosis in 130 patients. Intraoperative conversion to a hand-sewn anastomosis was necessary in 11 patients because of inadequate target site preparation, inappropriate target vessel selection, or both. Inadequate blood flow related to poor runoff required conversion in 3 additional patients. Three patients died before discharge of causes unrelated to the device. At discharge, 113 patients had a C-Port implant in place, and 104 C-Port anastomoses were studied by means of angiography, resulting in 100 FitzGibbon A, 3 FitzGibbon B, and 1 FitzGibbon 0 classifications. At 6 months, one additional patient died of a device-unrelated cause, and 98 patients were evaluated by means of angiography (n = 89). Overall patency (FitzGibbon A) was 92.1%. Three C-Port anastomoses were rated FitzGibbon B, and 4 were rated FitzGibbon 0. At 12 months, 107 (98.2%) of 109 alive patients were followed up, without any reports of device-related major adverse cardiac events. CONCLUSIONS: The C-Port System allows for a rapid, reliable, and compliant distal anastomosis and yields favorable 6-month angiographic and 12-month clinical results when compared with published studies.
Resumo:
Surgery and other invasive therapies are complex interventions, the assessment of which is challenged by factors that depend on operator, team, and setting, such as learning curves, quality variations, and perception of equipoise. We propose recommendations for the assessment of surgery based on a five-stage description of the surgical development process. We also encourage the widespread use of prospective databases and registries. Reports of new techniques should be registered as a professional duty, anonymously if necessary when outcomes are adverse. Case series studies should be replaced by prospective development studies for early technical modifications and by prospective research databases for later pre-trial evaluation. Protocols for these studies should be registered publicly. Statistical process control techniques can be useful in both early and late assessment. Randomised trials should be used whenever possible to investigate efficacy, but adequate pre-trial data are essential to allow power calculations, clarify the definition and indications of the intervention, and develop quality measures. Difficulties in doing randomised clinical trials should be addressed by measures to evaluate learning curves and alleviate equipoise problems. Alternative prospective designs, such as interrupted time series studies, should be used when randomised trials are not feasible. Established procedures should be monitored with prospective databases to analyse outcome variations and to identify late and rare events. Achievement of improved design, conduct, and reporting of surgical research will need concerted action by editors, funders of health care and research, regulatory bodies, and professional societies.
Resumo:
PURPOSE: This retrospective study reports the clinical outcome following placement of extraoral implants in severely resorbed posterior ridges to support distal-extension removable dentures. MATERIAL AND METHODS: Consecutively treated patients with partially or completely edentulous ridges, with available bone height in the posterior region of 6 mm or less, were included in the study. Implants originally intended for extraoral use (Straumann) were placed in second molar regions and allowed to heal for 4 to 6 months before abutment connection. At recall appointments, the peri-implant hard and soft tissues were evaluated. Complications with implant components, as well as mechanical and structural failures of the prostheses, were recorded. Two-year survival rates were calculated and life table analyses undertaken. RESULTS: Twenty-nine patients (19 women and 10 men; average age 61.2 years, range, 44 to 75 years) were included in the study. Forty-seven extraoral implants in 26 patients were placed in the second molar site of the mandible. Two extraoral implants in 2 patients failed during the osseointegration phase, yielding an 8-year cumulative success rate of 91.8%. The mean distance from the extraoral implants to the most distal tooth/implant was 28.1 mm (range, 16.7 to 39.2 mm). Twenty-three extraoral implants were restored with magnets, 18 with ball anchors, and 4 with conical cylinders. Replacement of abutments and retention elements was necessary in 2 patients. Four abutments in 2 patients were disconnected from the restorations. CONCLUSIONS: Within the limits of the employed research design, extraoral implants may be used successfully to provide support for distal-extension removable dentures in severely resorbed posterior alveolar ridges.
Resumo:
BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.
Clinical Evaluation of a Fully-automatic Segmentation Method for Longitudinal Brain Tumor Volumetry.
Resumo:
Information about the size of a tumor and its temporal evolution is needed for diagnosis as well as treatment of brain tumor patients. The aim of the study was to investigate the potential of a fully-automatic segmentation method, called BraTumIA, for longitudinal brain tumor volumetry by comparing the automatically estimated volumes with ground truth data acquired via manual segmentation. Longitudinal Magnetic Resonance (MR) Imaging data of 14 patients with newly diagnosed glioblastoma encompassing 64 MR acquisitions, ranging from preoperative up to 12 month follow-up images, was analysed. Manual segmentation was performed by two human raters. Strong correlations (R = 0.83-0.96, p < 0.001) were observed between volumetric estimates of BraTumIA and of each of the human raters for the contrast-enhancing (CET) and non-enhancing T2-hyperintense tumor compartments (NCE-T2). A quantitative analysis of the inter-rater disagreement showed that the disagreement between BraTumIA and each of the human raters was comparable to the disagreement between the human raters. In summary, BraTumIA generated volumetric trend curves of contrast-enhancing and non-enhancing T2-hyperintense tumor compartments comparable to estimates of human raters. These findings suggest the potential of automated longitudinal tumor segmentation to substitute manual volumetric follow-up of contrast-enhancing and non-enhancing T2-hyperintense tumor compartments.