127 resultados para Esophageal atresia
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Esophageal dilation often leads to long-lasting relief of dysphagia in eosinophilic esophagitis (EoE). The aim of this study was to define the effectiveness, safety, and patient acceptance of esophageal dilation in EoE. In addition, we examined the influence of dilation on the underlying esophageal inflammation.
Resumo:
There is no standard treatment for patients with locally advanced esophageal carcinoma without systemic metastasis in whom surgery is no longer considered a reasonable option.
Resumo:
This multicenter phase IB/II trial investigated cetuximab added to preoperative chemoradiotherapy for esophageal cancer.
Resumo:
EUS response assessment in patients with locally advanced esophageal cancer undergoing neoadjuvant chemoradiation therapy (CRT) is limited by disintegration of the involved anatomic structures.
Resumo:
Gastro-esophageal reflux is considered a major culprit in the pathogenesis of Barrett's esophagus (BE). Still, there is controversy on the role of weakly acidic and weakly alkaline reflux in BE. To compare characteristics of reflux episodes patients with BE, erosive esophagitis (EE), and healthy volunteers (HV).
Resumo:
Two healthy cats underwent elective surgical procedures under general anesthesia. One developed severe esophagitis leading to esophageal rupture, mediastinitis, and pyothorax. The other cat developed esophageal stricture, diverticulum formation, and suspected iatrogenic perforation. Both cats had signs of dysphagia and regurgitation beginning a few days after anesthesia. The first cat also had severe dyspnea due to septic pleural effusion and pneumomediastinum. In the second cat, endoscopy revealed diffuse esophagitis, an esophageal stricture, and a large esophageal diverticulum. Rupture of the esophageal wall occurred while inflating the esophagus for inspection. Due to the poor prognosis, both cats were euthanized. Necropsy revealed severe esophageal changes. Postanesthetic esophagitis has been previously described in dogs and cats; however, severe life-threatening esophageal injuries rarely occur as a sequel to general anesthesia. To the authors' knowledge, esophageal rupture secondary to perianesthetic reflux has never been reported in cats.
Resumo:
A 2-year-old Red Holstein cow was presented with uterine torsion at 235 days of pregnancy. The fetus extracted by cesarean section had weak vital signs and marked abdominal distention. An edematous pouch that contained tubular structures with peristaltic activity was associated with the umbilical cord. Because of poor prognosis, both dam and fetus were euthanized. At necropsy, the fetus had severe distention of the forestomachs, abomasum, and proximal small intestine; absence of distal small intestine, cecum, and proximal colon; atresia of the 2 blind ends of the intestine; and atrophy of distal colon and rectum. The tubular structures associated with the umbilical cord were identified as the segments of intestine that were absent in the fetus. Intestinal atresia combined with ectopia may be caused by local ischemia during temporary herniation and rotation of the fetal gut into the extraembryonic coelom. The close connection between ectopic intestine and amniotic sheath of the umbilical cord in this case may have facilitated vascularization and allowed development and viability of the ectopic intestine.
Resumo:
Three horses (age 17 - 23 years) were referred to the equine clinic of the University of Berne due to colic, fever, tachycardia and tachypnea. All horses showed pleural effusion. Clinical findings in 2 of the horses were highly suggestive of an intra-thoracic esophageal perforation. Severe septic pleuropneumonia without suspicion of an esophageal lesion was diagnosed in the 3rd horse. In addition, an 11 year old stallion was referred to the equine clinic for treatment of a presumptive large colon impaction. The horse was given laxatives after nasogastric intubation. Subsequent dramatic clinical deterioration and signs consistent with severe pleuropneumonia suggest that esophageal perforation had occurred when passing the nasogastric tube. All 4 horses were euthanized due to a poor prognosis. Esophageal perforation was diagnosed or confirmed post mortem in all cases. A hypertrophy of the tunica muscularis of the intra-thoracic esophagus was found in 3 of 4 horses.
Resumo:
Introduction: Diagnosing arrhythmias by conventional Holter-ECG can be cumbersome because of artifacts, skin irritation and poor P-waves. In contrast, esophageal electrocardiography (eECG) is promising due to the anatomic relationship of the esophagus to the atria and its favorable bioelectric properties. Methods used: In an ambulant setting, we recorded eECGs from 10 volunteers with a novel, highly-miniaturized eECG recorder that is worn discretely behind the ear (1.5×1.8×5cm, 22grams). The device continuously records two eECG leads during 3 days with 500Hz sampling frequency and 24-bit resolution. Results: Mean ± SD recording time was 21.7±19.6 hours (max. 60 hours). Test persons were not limited in daily activities (e.g. eating, speaking) and only complained mild discomfort during probe insertion, which subsided later on. During 99.8% of time, the recorder acquired signals appropriate for further analysis. In unfiltered data, QRS complexes and P-waves were identifiable during >98% of time. P waves had higher amplitudes as compared to surface ECG (0.71 ± 0.42mV vs. 0.16 ± 0.03mV, p = 0.004). No complications occurred. Conclusion: Ambulatory eECG recording is safe, well tolerated and promising due to excellent P-wave detection, overcoming some limitations of conventional Holter ECG.
Resumo:
Two commercially available electrode catheters are examined for their suitability in esophageal long-term ECG recordings. Both, electrical sensing characteristics as well as clinical acceptance were investigated in a clinical study including inpatients with cardiovascular diseases. In total, 31 esophageal ECG were obtained in 36 patients. Results showed that esophageal electrodes were well tolerated by the patients. Hemispherical electrodes with higher diameter required more insertion attempts and were associated with increased failure rates as compared to cylindrical electrodes. In contrast, the higher surface area of hemispherical electrodes resulted in significantly higher signal-to-noise ratio. Contact impedance was equal for both electrode types, but esophageal electrodes had lower impedance if compared with skin electrodes.