79 resultados para Error tolerance

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate geriatric assessment (GA) domains in relation to clinically important outcomes in older breast cancer survivors. Methods Six hundred sixty women diagnosed with primary breast cancer in four US geographic regions (Los Angeles, CA; Minnesota; North Carolina; and Rhode Island) were selected with disease stage I to IIIA, age ≥ 65 years at date of diagnosis, and permission from attending physician to contact. Data were collected over 7 years of follow-up from consenting patients' medical records, telephone interviews, physician questionnaires, and the National Death Index. Outcomes included self-reported treatment tolerance and all-cause mortality. Four GA domains were described by six individual measures, as follows: sociodemographic by adequate finances; clinical by Charlson comorbidity index (CCI) and body mass index; function by number of physical function limitations; and psychosocial by the five-item Mental Health Index (MHI5) and Medical Outcomes Study Social Support Survey (MOS-SSS). Associations were evaluated using t tests, χ2 tests, and regression analyses. Results In multivariable regression including age and stage, three measures from two domains (clinical and psychosocial) were associated with poor treatment tolerance; these were CCI ≥ 1 (odds ratio [OR] = 2.49; 95% CI, 1.18 to 5.25), MHI5 score less than 80 (OR = 2.36; 95% CI, 1.15 to 4.86), and MOS-SSS score less than 80 (OR = 3.32; 95% CI, 1.44 to 7.66). Four measures representing all four GA domains predicted mortality; these were inadequate finances (hazard ratio [HR] = 1.89; 95% CI, 1.24 to 2.88; CCI ≥ 1 (HR = 1.38; 95% CI, 1.01 to 1.88), functional limitation (HR = 1.40; 95% CI, 1.01 to 1.93), and MHI5 score less than 80 (HR = 1.34; 95% CI, 1.01 to 1.85). In addition, the proportion of women with these outcomes incrementally increased as the number of GA deficits increased. Conclusion This study provides longitudinal evidence that GA domains are associated with poor treatment tolerance and predict mortality at 7 years of follow-up, independent of age and stage of disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mucosal immunity protects the epithelial barrier by immune exclusion of foreign antigens and by anti-inflammatory tolerance mechanisms, but there is a continuing debate about the role of secretory immunoglobulins (SIgs), particularly SIgA, in the protection against allergy and other inflammatory diseases. Lack of secretory antibodies may cause immune dysfunction and affect mucosally induced (oral) tolerance against food antigens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients can make contributions to the safety of chemotherapy administration but little is known about their motivations to participate in safety-enhancing strategies. The theory of planned behavior was applied to analyze attitudes, norms, behavioral control, and chemotherapy patients' intentions to participate in medical error prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Sedation prior to performance of diagnostic esophagogastroduodenoscopy (EGDE) is widespread and increases patient comfort. But 98% of all serious adverse events during EGDEs are ascribed to sedation. The S3 guideline for sedation procedures in gastrointestinal endoscopy published in 2008 in Germany increases patient safety by standardization. These new regulations increase costs because of the need for more personnel and a prolonged discharge procedure after examinations with sedation. Many patients have difficulties to meet the discharge criteria regulated by the S3 guideline, e.g. the call for a second person to escort them home, to resign from driving and working for the rest of the day, resulting in a refusal of sedation. Therefore, we would like to examine if an acupuncture during elective, diagnostic EGDEs could increase the comfort of patients refusing systemic sedation. Methods/Design A single-center, double blinded, placebo controlled superiority trial to compare the success rates of elective, diagnostic EGDEs with real and placebo acupuncture. All patients aged 18 years or older scheduled for elective, diagnostic EGDE who refuse a systemic sedation are eligible. 354 patients will be randomized. The primary endpoint is the rate of successful EGDEs with the randomized technique. Intervention: Real or placebo acupuncture before and during EGDE. Duration of study: Approximately 24 months. Discussion Organisation/Responsibility The ACUPEND - Trial will be conducted in accordance with the protocol and in compliance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989) and Good Clinical Practice (GCP). The Interdisciplinary Endoscopy Center (IEZ) of the University Hospital Heidelberg is responsible for design and conduct of the trial, including randomization and documentation of patients' data. Data management and statistical analysis will be performed by the independent Institute for Medical Biometry and Informatics (IMBI) and the Center of Clinical Trials (KSC) at the Department of General, Visceral and Transplantation Surgery, University of Heidelberg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical errors are a serious threat to chemotherapy patients. Patients can make contributions to safety but little is known about the acceptability of error-preventing behaviors and its predictors.