21 resultados para Engineering, Electronics and Electrical|Computer Science

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. RESULTS The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent studies have shown that the nociceptive withdrawal reflex threshold (NWR-T) and the electrical pain threshold (EP-T) are reliable measures in pain-free populations. However, it is necessary to investigate the reliability of these measures in patients with chronic pain in order to translate these techniques from laboratory to clinic. The aims of this study were to determine the test-retest reliability of the NWR-T and EP-T after single and repeated (temporal summation) electrical stimulation in a group of patients with chronic low back pain, and to investigate the association between the NWR-T and the EP-T. To this end, 25 patients with chronic pain participated in three identical sessions, separated by 1 week in average, in which the NWR-T and the EP-T to single and repeated stimulation were measured. Test-retest reliability was assessed using intra-class correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analysis. The association between the thresholds was assessed using the coefficient of determination (r (2)). The results showed good-to-excellent reliability for both NWR-T and EP-T in all cases, with average ICC values ranging 0.76-0.90 and average CV values ranging 12.0-17.7%. The association between thresholds was better after repeated stimulation than after single stimulation, with average r (2) values of 0.83 and 0.56, respectively. In conclusion, the NWR-T and the EP-T are reliable assessment tools for assessing the sensitivity of spinal nociceptive pathways in patients with chronic pain.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND A majority of patients undergoing ablation of ventricular tachycardia have implanted devices precluding substrate imaging with delayed-enhancement MRI. Contrast-enhanced multidetector computed tomography (MDCT) can depict myocardial wall thickness with submillimetric resolution. We evaluated the relationship between regional myocardial wall thinning (WT) imaged by MDCT and arrhythmogenic substrate in postinfarction ventricular tachycardia. METHODS AND RESULTS We studied 13 consecutive postinfarction patients undergoing MDCT before ablation. MDCT data were integrated with high-density 3-dimensional electroanatomic maps acquired during sinus rhythm (endocardium, 509±291 points/map; epicardium, 716±323 points/map). Low-voltage areas (<1.5 mV) and local abnormal ventricular activities (LAVA) during sinus rhythm were assessed with regard to the WT. A significant correlation was found between the areas of WT <5 mm and endocardial low voltage (correlation-R=0.82; P=0.001), but no such correlation was found in the epicardium. The WT <5 mm area was smaller than the endocardial low-voltage area (54 cm(2) [Q1-Q3, 46-92] versus 71 cm(2) [Q1-Q3, 59-124]; P=0.001). Among a total of 13 060 electrograms reviewed in the whole study population, 538 LAVA were detected and analyzed. LAVA were located within the WT <5 mm (469/538 [87%]) or at its border (100% within 23 mm). Very late LAVA (>100 ms after QRS complex) were almost exclusively detected within the thinnest area (93% in the WT<3 mm). CONCLUSIONS Regional myocardial WT correlates to low-voltage regions and distribution of LAVA critical for the generation and maintenance of postinfarction ventricular tachycardia. The integration of MDCT WT with 3-dimensional electroanatomic maps can help focus mapping and ablation on the culprit regions, even when MRI is precluded by the presence of implanted devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels. MATERIALS AND METHODS An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5-12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity. RESULTS Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1=0.063, p2=0.016). Highest sensitivities--between 97% and 99.0%--were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p<0.03). CONCLUSIONS Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Debuggers are crucial tools for developing object-oriented software systems as they give developers direct access to the running systems. Nevertheless, traditional debuggers rely on generic mechanisms to explore and exhibit the execution stack and system state, while developers reason about and formulate domain-specific questions using concepts and abstractions from their application domains. This creates an abstraction gap between the debugging needs and the debugging support leading to an inefficient and error-prone debugging effort. To reduce this gap, we propose a framework for developing domain-specific debuggers called the Moldable Debugger. The Moldable Debugger is adapted to a domain by creating and combining domain-specific debugging operations with domain-specific debugging views, and adapts itself to a domain by selecting, at run time, appropriate debugging operations and views. We motivate the need for domain-specific debugging, identify a set of key requirements and show how our approach improves debugging by adapting the debugger to several domains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Imprecise manipulation of source code (semi-parsing) is useful for tasks such as robust parsing, error recovery, lexical analysis, and rapid development of parsers for data extraction. An island grammar precisely defines only a subset of a language syntax (islands), while the rest of the syntax (water) is defined imprecisely. Usually, water is defined as the negation of islands. Albeit simple, such a definition of water is naive and impedes composition of islands. When developing an island grammar, sooner or later a programmer has to create water tailored to each individual island. Such an approach is fragile, however, because water can change with any change of a grammar. It is time-consuming, because water is defined manually by a programmer and not automatically. Finally, an island surrounded by water cannot be reused because water has to be defined for every grammar individually. In this paper we propose a new technique of island parsing - bounded seas. Bounded seas are composable, robust, reusable and easy to use because island-specific water is created automatically. We integrated bounded seas into a parser combinator framework as a demonstration of their composability and reusability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One key problem in modern medical imaging is linking measured data and actual physiological quantities. In this article we derive such a link between the electrical bioimpedance of lung parenchyma, which can be measured by electrical impedance tomography (EIT), and the magnitude of regional ventilation, a key to understanding lung mechanics and developing novel protective ventilation strategies. Two rat-derived three-dimensional alveolar microstructures obtained from synchrotron-based x-ray tomography are each exposed to a constant potential difference for different states of ventilation in a finite element simulation. While the alveolar wall volume remains constant during stretch, the enclosed air volume varies, similar to the lung volume during ventilation. The enclosed air, serving as insulator in the alveolar ensemble, determines the resulting current and accordingly local tissue bioimpedance. From this we can derive a relationship between lung tissue bioimpedance and regional alveolar ventilation. The derived relationship shows a linear dependence between air content and tissue impedance and matches clinical data determined from a ventilated patient at the bedside.