23 resultados para Energy Density

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of sqrt(s) = 7 TeV corresponding to an integrated luminosity of 38 inverse pb. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0.4 or R=0.6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pt > 20 GeV and pseudorapidities eta<4.5. The JES systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams. The JES uncertainty is less than 2.5% in the central calorimeter region (eta<0.8) for jets with 60 < pt < 800 GeV, and is maximally 14% for pt < 30 GeV in the most forward region 3.2energy from multiple proton-proton collisions in the same bunch crossing is less than 1.5% per additional collision for jets with pt > 50 GeV after a dedicated correction for this effect. The JES is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pt, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pt jets recoiling against a high-pt jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, providing an improved jet energy resolution and a reduced flavour dependence of the jet response. The JES systematic uncertainty determined from a combination of in situ techniques are consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pt jets.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Homeorhetic and homeostatic controls in dairy cows are essential for adapting to alterations in physiological and environmental conditions. To study the different mechanisms during adaptation processes, effects of a deliberately induced negative energy balance (NEB) by feed restriction near 100 d in milk (DIM) on performance and metabolic measures were compared with lactation energy deficiency after parturition. Fifty multiparous cows were studied in 3 periods (1=early lactation up to 12 wk postpartum; 2=feed restriction for 3 wk beginning at 98+/-7 DIM with a feed-restricted and control group; and 3=a subsequent realimentation period for the feed-restricted group for 8 wk). In period 1, despite NEB in early lactation [-42 MJ of net energy for lactation (NE(L))/d, wk 1 to 3] up to wk 9, milk yield increased from 27.5+/-0.7 kg to a maximum of 39.5+/-0.8 kg (wk 6). For period 2, the NEB was induced by individual limitation of feed quantity and reduction of dietary energy density. Feed-restricted cows experienced a greater NEB (-63 MJ of NEL/d) than did cows in early lactation. Feed-restricted cows in period 2 showed only a small decline in milk yield of -3.1+/-1.1 kg and milk protein content of -0.2+/-0.1% compared with control cows (30.5+/-1.1 kg and 3.8+/-0.1%, respectively). In feed-restricted cows (period 2), plasma glucose was lower (-0.2+/-0.0 mmol/L) and nonesterified fatty acids higher (+0.1+/-0.1 mmol/L) compared with control cows. Compared with the NEB in period 1, the decreases in body weight due to the deliberately induced NEB (period 2) were greater (56+/-4 vs. 23+/-3 kg), but decreases in body condition score (0.16+/-0.03 vs. 0.34+/-0.04) and muscle diameter (2.0+/-0.4 vs. 3.5+/-0.4 mm) were lesser. The changes in metabolic measures in period 2 were marginal compared with the adjustments directly after parturition in period 1. Despite the greater induced energy deficiency at 100 DIM than the early lactation NEB, the metabolic load experienced by the dairy cows was not as high as that observed in early lactation. The different effects of energy deficiency at the 2 stages in lactation show that metabolic problems in early lactating dairy cows are not due only to the NEB, but mainly to the specific metabolic regulation during this period.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Human energy harvesting is envisioned as a remedy to the weight, the size, and the poor energy density of primary batteries in medical implants. The first implant to have necessarily raised the idea of a biological power supply was the pacemaker in the early 1960s. So far, review articles on human energy harvesting have been rather unspecific and no tribute has been given to the early role of the pacemaker and the cardiovascular system in triggering research in the field. The purpose of the present article is to provide an up-to-date review of research efforts targeting the cardiovascular system as an alternative energy source for active medical implants. To this end, a chronological survey of the last 14 most influential publications is proposed. They include experimental and/or theoretical studies based on electromagnetic, piezoelectric, or electrostatic transducers harnessing various forms of energy, such as heart motion, pressure gradients, and blood flow. Technical feasibility does not imply clinical applicability: although most of the reported devices were shown to harvest an interesting amount of energy from a physiological environment, none of them were tested in vivo for a longer period of time.Human energy harvesting is envisioned as a remedy to the weight, the size, and the poor energy density of primary batteries in medical implants. The first implant to have necessarily raised the idea of a biological power supply was the pacemaker in the early 1960s. So far, review articles on human energy harvesting have been rather unspecific and no tribute has been given to the early role of the pacemaker and the cardiovascular system in triggering research in the field. The purpose of the present article is to provide an up-to-date review of research efforts targeting the cardiovascular system as an alternative energy source for active medical implants. To this end, a chronological survey of the last 14 most influential publications is proposed. They include experimental and/or theoretical studies based on electromagnetic, piezoelectric, or electrostatic transducers harnessing various forms of energy, such as heart motion, pressure gradients, and blood flow. Technical feasibility does not imply clinical applicability: although most of the reported devices were shown to harvest an interesting amount of energy from a physiological environment, none of them were tested in vivo for a longer period of time.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of sqrt(s) = 7 TeV corresponding to an integrated luminosity of 38 inverse pb. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0.4 or R=0.6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pt > 20 GeV and pseudorapidities eta<4.5. The JES systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams. The JES uncertainty is less than 2.5% in the central calorimeter region (eta<0.8) for jets with 60 < pt < 800 GeV, and is maximally 14% for pt < 30 GeV in the most forward region 3.2energy from multiple proton-proton collisions in the same bunch crossing is less than 1.5% per additional collision for jets with pt > 50 GeV after a dedicated correction for this effect. The JES is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pt, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pt jets recoiling against a high-pt jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, providing an improved jet energy resolution and a reduced flavour dependence of the jet response. The JES systematic uncertainty determined from a combination of in situ techniques are consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pt jets.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To investigate the effect of curing rate on softening in ethanol, degree of conversion, and wear of resin composites. METHOD: With a given energy density and for each of two different light-curing units (QTH or LED), the curing rate was reduced by modulating the curing mode. Thus, the irradiation of resin composite specimens (Filtek Z250, Tetric Ceram, Esthet-X) was performed in a continuous curing mode and in a pulse-delay curing mode. Wallace hardness was used to determine the softening of resin composite after storage in ethanol. Degree of conversion was determined by infrared spectroscopy (FTIR). Wear was assessed by a three-body test. Data were submitted to Levene's test, one and three-way ANOVA, and Tukey HSD test (alpha = 0.05). Results: Immersion in ethanol, curing mode, and material all had significant effects on Wallace hardness. After ethanol storage, resin composites exposed to the pulse-delay curing mode were softer than resin composites exposed to continuous cure (P< 0.0001). Tetric Ceram was the softest material followed by Esthet-X and Filtek Z250 (P< 0.001). Only the restorative material had a significant effect on degree of conversion (P< 0.001): Esthet-X had the lowest degree of conversion followed by Filtek Z250 and Tetric Ceram. Curing mode (P= 0.007) and material (P< 0.001) had significant effect on wear. Higher wear resulted from the pulse-delay curing mode when compared to continuous curing, and Filtek Z250 showed the lowest wear followed by Esthet-X and Tetric Ceram.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tissue grafts are implanted in orthopedic surgery every day. In order to minimize infection risk, bone allografts are often delipidated with supercritical CO2 and sterilized prior to implantation. This treatment may, however, impair the mechanical behavior of the bone graft tissue. The goal of this study was to determine clinically relevant mechanical properties of treated/sterilized human trabecular bone grafts, e.g. the apparent modulus, strength, and the ability to absorb energy during compaction. They were compared with results of identical experiments performed previously on untreated/fresh frozen human trabecular bone from the same anatomical site (Charlebois, 2008). We tested the hypothesis that the morphology–mechanical property relationships of treated cancellous allografts are similar to those of fresh untreated bone. The morphology of the allografts was determined by μCT. Subsequently, cylindrical samples were tested in unconfined and confined compression. To account for various morphologies, the experimental data was fitted to phenomenological mechanical models for elasticity, strength, and dissipated energy density based on bone volume fraction (BV/TV) and the fabric tensor determined by MIL. The treatment/sterilization process does not appear to influence bone graft stiffness. However, strength and energy dissipation of the bone grafts were found to be significantly reduced by 36% to 47% and 66% to 81%, respectively, for a broad range of volume fraction (0.14 < BV/TV < 0.39) and degree of anisotropy (1.24 < DA < 2.18). Since the latter properties are strongly dominated by BV/TV, the clinical consequences of this reduction can be compensated by using grafts with lower porosity. The data of this study suggests that an increase of 5–10% in BV/TV is sufficient to compensate for the reduced post-yield mechanical properties of treated/sterilized bone in monotonic compression. In applications where graft stiffness needs to be matched and strength is not a concern, treated allograft with the same BV/TV as an appropriate fresh bone graft may be used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Even though the Standard Model with a Higgs mass mH = 125GeV possesses no bulk phase transition, its thermodynamics still experiences a "soft point" at temperatures around T = 160GeV, with a deviation from ideal gas thermodynamics. Such a deviation may have an effect on precision computations of weakly interacting dark matter relic abundances if their mass is in the few TeV range, or on leptogenesis scenarios operating in this temperature range. By making use of results from lattice simulations based on a dimensionally reduced effective field theory, we estimate the relevant thermodynamic functions across the crossover. The results are tabulated in a numerical form permitting for their insertion as a background equation of state into cosmological particle production/decoupling codes. We find that Higgs dynamics induces a non-trivial "structure" visible e.g. in the heat capacity, but that in general the largest radiative corrections originate from QCD effects, reducing the energy density by a couple of percent from the free value even at T > 160GeV.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the physical Higgs mass the standard model symmetry restoration phase transition is a smooth cross-over. We study the thermodynamics of the cross-over using numerical lattice Monte Carlo simulations of an effective SU(2)×U(1) gauge+Higgs theory, significantly improving on previously published results. We measure the Higgs field expectation value, thermodynamic quantities like pressure, energy density, speed of sound and heat capacity, and screening masses associated with the Higgs and Z fields. While the cross-over is smooth, it is very well defined with a width of only ∼5  GeV. We measure the cross-over temperature from the maximum of the susceptibility of the Higgs condensate, with the result Tc=159.5±1.5  GeV. Outside of the narrow cross-over region the perturbative results agree well with nonperturbative ones.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the first part of this methodological study eleven metacarpi of 9 skeletally normal horses were examined from 4 directions by dual energy x-ray absorptiometry (DXA). The differences between the dorsopalmar-palmarodorsal and lateromedial-mediolateral (opposite sites) bone mineral density (BMD) values were found to be nonsignificant. In the second part of the study the precision of the Norland XR-26 densitometer was tested by measuring 34 metacarpal bones and 34 proximal phalanges, each of them three times, from a single direction. The difference between the individual measurements of the first phalanges and of the metacarpal bones originating from the right or the left side of the same horse were not significant, nor did the age or breed have a significant effect on BMD or bone mineral content (BMC). However, both BMD and BMC are greater in the metacarpal bones than in the proximal phalanges and are higher in geldings than in mares or to stallions, while the BMD or BMC values of mares and stallions did not differ from each other significantly. These data point to the necessity of further BMD studies in a higher number of patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To assess the effect of age and disease on mineral distribution at the distal third of the tibia, bone mineral content (BMC) and bone mineral density (BMD) were measured at lumbar spine (spine), femoral neck (neck), and diaphysis (Dia) and distal epiphysis (Epi) of the tibia in 89 healthy control women of different age groups (20-29, n = 12; 30-39, n = 11; 40-44, n = 12; 45-49, n = 12; 50-54, n = 12; 55-59, n = 10; 60-69, n = 11; 70-79, n = 9), in 25 women with untreated vertebral osteoporosis (VOP), and in 19 women with primary hyperparathyroidism (PHPT) using dual-energy x-ray absorptiometry (DXA; Hologic QDR 1000 and standard spine software). A soft tissue simulator was used to compensate for heterogeneity of soft tissue thickness around the leg. Tibia was scanned over a length of 130 mm from the ankle joint, fibula being excluded from analysis. For BMC and BMD, 10 sections 13 mm each were analyzed separately and then pooled to define the epiphysis (Epi 13-52 mm) and diaphysis area (Dia 91-130 mm). Precision after repositioning was 1.9 and 2.1% for Epi and Dia, respectively. In the control group, at any site there was no significant difference between age groups 20-29 and 30-39, which thus were pooled to define the peak bone mass (PBM).(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a kernel density correlation based nonrigid point set matching method and shows its application in statistical model based 2D/3D reconstruction of a scaled, patient-specific model from an un-calibrated x-ray radiograph. In this method, both the reference point set and the floating point set are first represented using kernel density estimates. A correlation measure between these two kernel density estimates is then optimized to find a displacement field such that the floating point set is moved to the reference point set. Regularizations based on the overall deformation energy and the motion smoothness energy are used to constraint the displacement field for a robust point set matching. Incorporating this non-rigid point set matching method into a statistical model based 2D/3D reconstruction framework, we can reconstruct a scaled, patient-specific model from noisy edge points that are extracted directly from the x-ray radiograph by an edge detector. Our experiment conducted on datasets of two patients and six cadavers demonstrates a mean reconstruction error of 1.9 mm

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Define links between psychosocial parameters and metabolic variables in obese females before and after a low-calorie diet. METHOD: Nine female obese patients (age 36.1 +/- 7.1 years, body mass index [BMI] > 30 kg/m2) were investigated before and after a 6-week low-calorie diet accompanied by behavior therapy. Blood lipids, insulin sensitivity (Bergman protocol), fat distribution (by dual-energy X-ray absorptiometry [DEXA]), as well as psychological parameters such as depression, anger, anxiety, symptom load, and well-being, were assessed before and after the dieting period. RESULTS: The females lost 9.6 +/- 2.8 kg (p < .0001) of body weight, their BMI was reduced by 3.5 +/- 0.3 kg/m2 (p < .0001), and insulin sensitivity increased from 3.0 +/- 1.8 to 4.3 +/- 1.5 mg/kg (p = .05). Their abdominal fat content decreased from 22.3 +/- 5.5 to 18.9 +/- 4.5 kg (p < .0001). In parallel, psychological parameters such as irritability (p < .05) and cognitive control (p < .0001) increased, whereas feelings of hunger (p < .05), externality (p < .05), interpersonal sensitivity (p < .01), paranoid ideation (p < .05), psychoticism (p < .01), and global severity index (p < .01) decreased. Prospectively, differences in body fat (percent) were correlated to nervousness (p < .05). Waist-to-hip ratio (WHR) differences were significantly correlated to sociability (p < .05) and inversely to emotional instability (p < .05), whereas emotional instability was inversely correlated to differences in insulin sensitivity (p < .01). DISCUSSION: Weight reduction may lead to better somatic risk factor control. Women with more nervousness and better sociability at the beginning of a diet period may lose more weight than others.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Reduced bone mineral density (BMD) is common in adults infected with human immunodeficiency virus (HIV). The role of proximal renal tubular dysfunction (PRTD) and alterations in bone metabolism in HIV-related low BMD are incompletely understood. METHODS: We quantified BMD (dual-energy x-ray absorptiometry), blood and urinary markers of bone metabolism and renal function, and risk factors for low BMD (hip or spine T score, -1 or less) in an ambulatory care setting. We determined factors associated with low BMD and calculated 10-year fracture risks using the World Health Organization FRAX equation. RESULTS: We studied 153 adults (98% men; median age, 48 years; median body mass index, 24.5; 67 [44%] were receiving tenofovir, 81 [53%] were receiving a boosted protease inhibitor [PI]). Sixty-five participants (42%) had low BMD, and 11 (7%) had PRTD. PI therapy was associated with low BMD in multivariable analysis (odds ratio, 2.69; 95% confidence interval, 1.09-6.63). Tenofovir use was associated with increased osteoblast and osteoclast activity (P< or = .002). The mean estimated 10-year risks were 1.2% for hip fracture and 5.4% for any major osteoporotic fracture. CONCLUSIONS: In this mostly male population, low BMD was significantly associated with PI therapy. Tenofovir recipients showed evidence of increased bone turnover. Measurement of BMD and estimation of fracture risk may be warranted in treated HIV-infected adults.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess bone mineral density (BMD) at different skeletal sites in women with hypothalamic or ovarian amenorrhea and the effect of estrogen-gestagen substitution on BMD we compared BMD of 21 amenorrheic patients with hypothalamic or ovarian amenorrhea with that of a control population of 123 healthy women. All amenorrheic patients were recruited from the outpatient clinic of the Division of Gynecological Endocrinology at the University of Berne, a public University Hospital. One hundred and twenty-three healthy, regularly menstruating women recruited in the Berne area served as a control group. BMD was measured using dual-energy X-ray absorptiometry (DXA). At each site where it was measured, mean BMD was lower in the amenorrheic group than in the control group. Compared with the control group, average BMD in the amenorrheic group was 85% at lumbar spine (p < 0.0001), 92% at femoral neck (p < 0.02), 90% at Ward's triangle (p < 0.03), 92% at tibial diaphysis (p < 0.0001) and 92% at tibial epiphysis (p < 0.03). Fifteen amenorrheic women received estrogen-gestagen replacement therapy (0.03 mg ethinylestradiol and 0.15 mg desogestrel daily for 21 days per month), bone densitometry being repeated within 12-24 months. An annual increase in BMD of 0.2% to 2.9% was noted at all measured sites, the level of significance being reached at the lumbar spine (p < 0.0012) and Ward's triangle (p < 0.033). In conclusion BMD is lower in amenorrheic young women than in a population of normally menstruating, age-matched women in both mainly trabecular (lumbar spine, Ward's triangle, tibial epiphysis) and mainly cortical bone (femoral neck, tibial diaphysis).(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To study the effect of fluoride on bone mineral density (BMD) in patients treated chronically with glucocorticosteroids, 15 subjects (renal grafted, n = 12; skin disease, n = 1; broncho pulmonary disorder, n = 1; Crohn's disease, n = 1) were prospectively studied in a double-blinded manner and randomly allocated either to group 1 (n = 8) receiving 13.2 mg/day fluoride given as disodium monofluorophosphate (MFP) supplemented with calcium (1,000 mg/day) and 25-hydroxyvitamin D (calcifediol) (50 micrograms/day), or to group 2 (n = 7) receiving Cas+ calcifediol alone. An additional group of 14 renal transplant patients treated chronically with glucocorticosteroids but exempt of specific therapeutic intervention for bone disease was set up as historical controls. BMD was measured by dual-energy X-ray absorptiometry (DXA, Hologic QDR 1000) performed at months 0, 6 and 12 for groups 1 and 2 (lumbar spine, total upper femur, diaphysis and epiphysis of distal tibia), or 11-31 months apart with calculation of linear yearly changes for the historical cohort. Lumbar BMD tended to rise in groups 1 and 2, and to fall in group 3, the change reaching statistical significance (p < 0.05) in group 1, thus leading to a significant difference between groups 1 and 3 (p < 0.05). At upper femur, tibial diaphysis and tibial epiphysis, no significant change in BMD occurred in any of the groups. In conclusion, lumbar BMD rises more after a mild dosis of fluoride given as MFP and combined to calcium and calcifediol than on Ca+ calcifediol alone, without changes in BMD at the upper femur or distal tibia.