44 resultados para Endobronchial Intubation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the use of the SensaScope, an S-shaped rigid fibreoptic scope with a flexible distal end, in a series of 13 patients at high risk of, or known to have, a difficult intubation. Patients received conscious sedation with midazolam or fentanyl combined with a remifentanil infusion and topical lidocaine to the oral mucosa and to the trachea via a trans-cricoid injection. Spontaneous ventilation was maintained until confirmation of tracheal intubation. In all cases, tracheal intubation was achieved using the SensaScope. The median (IQR [range]) insertion time (measured from the time the facemask was taken away from the face until an end-expiratory CO(2) reading was visible on the monitor) was 58 s (38-111 [28-300]s). In nine of the 13 cases, advancement of the SensaScope into the trachea was easy. Difficulties included a poor view associated with a bleeding diathesis and saliva, transient loss of spontaneous breathing, and difficulty in advancing the tracheal tube in a patient with unforeseen tracheal narrowing. A poor view in two patients was partially improved by a high continuous flow of oxygen. The SensaScope may be a valuable alternative to other rigid or flexible fibreoptic scopes for awake intubation of spontaneously breathing patients with a predicted difficult airway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The i-gel™ is a single-use supraglottic airway device (SAD) that allows fibreoptic-guided tracheal intubation through the device. Until now, no prospective data for this procedure are available. Therefore, in a prospective randomized controlled trial, we evaluated fibreoptic-guided tracheal intubation with a standard Rüsch™ PVC tracheal tube (TT) through the i-gel™ compared with the single-use ILMA™ (sILMA™) TT through the sILMA™ in patients with a predicted difficult airway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: This case report describes the anaesthetic management of exploratory thoracoscopy and alternating one lung ventilation (OLV) in a dog with a pulmonary bulla, and the application of continuous positive airway pressure (CPAP) to the non-ventilated lung for preventing and treating hypoxia. CASE HISTORY: A 6-year-old, male castrated Border collie was scheduled for exploratory thoracoscopy to investigate spontaneous pnemothorax that had not resolved with repeated suction. Specific requirements for the thoracoscopy were alternating OLV to allow the surgical access to the right middle lobe and its removal, and the examination of the left hemithorax to rule out the presence of other lesions. DIAGNOSIS AND MANAGEMENT: Selective lung ventilation was performed with a double lumen endobronchial tube (DLT), inserted under endoscopic guidance. After a short period of two lung ventilation during preparation of the surgical field, alternating OLV was performed, combining CPAP, provided to the non-ventilated lung via a Mapleson D breathing system, and positive end-expiratory pressure (PEEP) applied to the ventilated lung. Left OLV occurred first and resection of the right middle pulmonary lobe was successfully performed; right OLV followed to allow the examination of the left hemithorax. DISCUSSION AND CONCLUSIONS: The combination of CPAP and PEEP resulted in a satisfactory intra-operative management of hypoxemia. Alternating OLV can be performed successfully by using a DLT. CPAP, commonly employed in human medicine, should be considered an important tool in the anaesthetic management of OLV in small animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical ventilation (MV) is life-saving but potentially harmful for lungs of premature infants. So far, animal models dealt with the acute impact of MV on immature lungs, but less with its delayed effects. We used a newborn rodent model including non-surgical and therefore reversible intubation with moderate ventilation and hypothesized that there might be distinct gene expression patterns after a ventilation-free recovery period compared to acute effects directly after MV. Newborn rat pups were subjected to 8 hr of MV with 60% oxygen (O(2)), 24 hr after injection of lipopolysaccharide (LPS), intended to create a low inflammatory background as often recognized in preterm infants. Animals were separated in controls (CTRL), LPS injection (LPS), or full intervention with LPS and MV with 60% O(2) (LPS + MV + O(2)). Lungs were recovered either directly following (T:0 hr) or 48 hr after MV (T:48 hr). Histologically, signs of ventilator-induced lung injury (VILI) were observed in LPS + MV + O(2) lungs at T:0 hr, while changes appeared similar to those known from patients with chronic lung disease (CLD) with fewer albeit larger gas exchange units, at T:48 hr. At T:0 hr, LPS + MV + O(2) increased gene expression of pro-inflammatory MIP-2. In parallel anti-inflammatory IL-1Ra gene expression was increased in LPS and LPS + MV + O(2) groups. At T:48 hr, pro- and anti-inflammatory genes had returned to their basal expression. MMP-2 gene expression was decreased in LPS and LPS + MV + O(2) groups at T:0 hr, but no longer at T:48 hr. MMP-9 gene expression levels were unchanged directly after MV. However, at T:48 hr, gene and protein expression increased in LPS + MV + O(2) group. In conclusion, this study demonstrates the feasibility of delayed outcome measurements after a ventilation-free period in newborn rats and may help to further understand the time-course of molecular changes following MV. The differences obtained from the two time points could be interpreted as an initial transitory increase of inflammation and a delayed impact of the intervention on structure-related genes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Video-laryngoscopes are marketed for intubation in difficult airway management. They provide a better view of the larynx and may facilitate tracheal intubation, but there is no adequately powered study comparing different types of video-laryngoscopes in a difficult airway scenario or in a simulated difficult airway situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Lung retrieval from non-heart-beating donors (NHBD) has been introduced into clinical practice successfully. However, because of potentially deleterious effects of warm ischemia on microvascular integrity, use of NHBD lungs is limited by short tolerable time periods before preservation. Recently, improvement of NHBD graft function was demonstrated by donor pre-treatment using aerosolized Ventavis (Schering Inc., Berlin, Germany). Currently, there is no information whether additional application of this approach in reperfusion can further optimize immediate graft function. MATERIAL AND METHODS: Asystolic pigs (n = 5/group) were ventilated for 180-min of warm ischemia (groups 1-3). In groups 2 and 3, 100 microg Ventavis were aerosolized over 30-min using an ultrasonic nebulizer (Optineb). Lungs were then retrogradely preserved with Perfadex and stored for 3-h. After left lung transplantation and contralateral lung exclusion, grafts were reperfused for 6-h. Only in group 3, another dose of 100 microg Ventavis was aerosolized during the first 30-min of reperfusion. Hemodynamics, pO2/FiO2 and dynamic compliance were monitored continuously and compared to controls. Intraalveolar edema was quantified stereologically, and extravascular-lung-water-index (EVLWI) was measured. Statistics comprised ANOVA analysis with repeated measurements. RESULTS: Dynamic compliance was significantly lower in both Ventavis groups, but additional administration did not result in further improvement. Oxygenation, pulmonary hemodynamics, EVLWI and intraalveolar edema formation were comparable between groups. CONCLUSIONS: Alveolar deposition of Ventavis in NHBD lungs before preservation significantly improves dynamic lung compliance and represents an important strategy for improvement of preservation quality and expansion of warm ischemic intervals. However, additional application of this method in early reperfusion is of no benefit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. METHODS: Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml(-1);Group 2: BIS 40-50, remifentanil 2 ng ml(-1); Group 3: BIS 40-50, remifentanil 4 ng ml(-1); Group 4: BIS 25-35, remifentanil 2 ng ml(-1); Group 5: BIS 55-65, remifentanil 2 ng ml(-1)]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. RESULTS: The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. CONCLUSION: Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Studies on airway remodeling in children with cystic fibrosis (CF) may be hampered by difficulty in obtaining evaluable endobronchial biopsy specimens because of large amounts of mucus and inflammation in the CF airway. We prospectively assessed how the quality of biopsy specimens obtained from children with CF compare with those from children with other airway diseases. METHODS: Fiberoptic bronchoscopy with endobronchial biopsy was performed in 67 CF children (age range, 0.2 to 16.8 years), 34 children with wheeze/asthma (W/A), and 64 control children with chronic respiratory symptoms. Up to three biopsy specimens were taken and stained with hematoxylin and eosin. Biopsy specimen size and structural composition were quantified using stereology. RESULTS: At least one evaluable biopsy specimen was obtained in 72% of CF children, in 79% of children with W/A, and in 72% of control subjects (difference was not significant). The use of large biopsy forceps (2.0 mm) rather than small biopsy forceps (1.0 mm) [odds ratio (OR), 5.8; 95% confidence interval (CI), 1.1 to 29.8; p = 0.037] and the number of biopsy specimens taken (odds ratio, 2.6; 95% confidence interval, 1.3 to 5.2; p = 0.006) significantly contributed to the success rate. Biopsy size and composition were similar between groups, except that CF children and those patients with W/A had a higher percentage of the biopsy specimen composed of muscle than did control subjects (median 6.2% and 9.7% vs 0.9%, respectively; p = 0.002). CONCLUSIONS: Biopsy size and quality are adequate for the study of airway remodeling in CF children as young as 2 months of age. Researchers should use large forceps when possible and take at least two biopsy specimens per patient. An increased airway smooth muscle content of the airway mucosa may contribute to the pathophysiology of CF lung disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Endobronchial biopsies are an important tool for the study of airway remodeling in children. We aimed to evaluate the impact of performing endobronchial biopsies as a part of fiberoptic bronchoscopy on the length of the procedure. METHODS: Clinically indicated fiberoptic bronchoscopy at which endobronchial biopsy was attempted as a part of a research protocol was performed in 40 children (median age 6 years, range 2 months-16 years). Time needed for airway inspection, bronchoalveolar lavage (BAL) with three aliquots of 1 ml/kg of 0.9% saline, sampling of three macroscopically adequate biopsies, teaching, and other interventions (e.g., removal of plugs) was recorded. The bronchoscopist was not aware that the procedure was being timed. RESULTS: Median (range) duration (min) was 2.5 (1.0-8.2) for airway inspection, 2.8 (1.7-9.4) for BAL, 5.3 (2.5-16.6) for biopsy sampling, 2.4 (1.5-6.6) for teaching and 4.1 (0.8-18.5) for other interventions. Three adequate biopsies were obtained in 33 (83%) children. Use of 2.0 mm biopsy forceps (via 4.0 and 4.9 mm bronchoscopes) rather than 1.0 mm (via 2.8 and 3.6 mm bronchoscopes) significantly reduced biopsy time (4.6 min vs. 8.4 min, P < 0.001). CONCLUSIONS: It takes a median of just over 5 min to obtain three endobronchial biopsies in children, which we consider an acceptable increase in the duration of fiberoptic bronchoscopy for the purpose of research.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endobronchial ultrasound (EBUS) has become a major advance in bronchoscopy. Substantial scientific evidence has confirmed its usefulness in lung cancer diagnosis and staging, as well as in other clinical settings. It is of growing importance that endoscopists perform and interpret this imaging method accurately, in order to optimize diagnosis and treatment of their patients. The present article provides a practical and comprehensible review of the two EBUS systems currently available and its main clinical indications.