18 resultados para Electronically interfaced
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Monte Carlo (MC) based dose calculations can compute dose distributions with an accuracy surpassing that of conventional algorithms used in radiotherapy, especially in regions of tissue inhomogeneities and surface discontinuities. The Swiss Monte Carlo Plan (SMCP) is a GUI-based framework for photon MC treatment planning (MCTP) interfaced to the Eclipse treatment planning system (TPS). As for any dose calculation algorithm, also the MCTP needs to be commissioned and validated before using the algorithm for clinical cases. Aim of this study is the investigation of a 6 MV beam for clinical situations within the framework of the SMCP. In this respect, all parts i.e. open fields and all the clinically available beam modifiers have to be configured so that the calculated dose distributions match the corresponding measurements. Dose distributions for the 6 MV beam were simulated in a water phantom using a phase space source above the beam modifiers. The VMC++ code was used for the radiation transport through the beam modifiers (jaws, wedges, block and multileaf collimator (MLC)) as well as for the calculation of the dose distributions within the phantom. The voxel size of the dose distributions was 2mm in all directions. The statistical uncertainty of the calculated dose distributions was below 0.4%. Simulated depth dose curves and dose profiles in terms of [Gy/MU] for static and dynamic fields were compared with the corresponding measurements using dose difference and γ analysis. For the dose difference criterion of ±1% of D(max) and the distance to agreement criterion of ±1 mm, the γ analysis showed an excellent agreement between measurements and simulations for all static open and MLC fields. The tuning of the density and the thickness for all hard wedges lead to an agreement with the corresponding measurements within 1% or 1mm. Similar results have been achieved for the block. For the validation of the tuned hard wedges, a very good agreement between calculated and measured dose distributions was achieved using a 1%/1mm criteria for the γ analysis. The calculated dose distributions of the enhanced dynamic wedges (10°, 15°, 20°, 25°, 30°, 45° and 60°) met the criteria of 1%/1mm when compared with the measurements for all situations considered. For the IMRT fields all compared measured dose values agreed with the calculated dose values within a 2% dose difference or within 1 mm distance. The SMCP has been successfully validated for a static and dynamic 6 MV photon beam, thus resulting in accurate dose calculations suitable for applications in clinical cases.
Resumo:
An efficient synthetic approach to a symmetrically functionalized tetrathiafulvalene (TTF) derivative with two diamine moieties, 2-[5,6-diamino-4,7-bis(4-pentylphenoxy)-1,3-benzodithiol-2-ylidene]-4,7- bis(4-pentylphenoxy)-1,3-benzodithiole-5,6-diamine (2), is reported. The subsequent Schiff-base reactions of 2 afford large p-conjugated multiple donoracceptor (DA) arrays, for example, the triad 2-[4,9-bis(4-pentylphenoxy)-1,3-dithiolo[4,5-g]quinoxalin-2-ylidene]-4,9 -bis(4-pentylphenoxy)-1,3-dithiolo[4,5-g]quinoxaline (8) and the corresponding tetrabenz[bc,ef,hi,uv]ovalene-fused pentad 1, in good yields and high purity. The novel redox-active nanographene 1 is so far the largest known TTF-functionalized polycyclic aromatic hydrocarbon (PAH) with a well-resolved 1H NMR spectrum. The electrochemically highly amphoteric pentad 1 and triad 8 exhibit various electronically excited charge-transfer states in different oxidation states, thus leading to intense optical intramolecular charge-transfer (ICT) absorbances over a wide spectral range. The chemical and electrochemical oxidations of 1 result in an unprecedented TTF+ radical cation dimerization, thereby leading to the formation of [1+]2 at room temperature in solution due to the stabilizing effect, which arises from strong pp interactions. Moreover, ICT fluorescence is observed with large solvent-dependent Stokes shifts and quantum efficiencies of 0.05 for 1 and 0.035 for 8 in dichloromethane.
Resumo:
OBJECTIVE: To design and evaluate a novel computer-assisted, fluoroscopy-based planning and navigation system for minimally invasive ventral spondylodesis of thoracolumbar fractures. MATERIALS AND METHODS: Instruments and an image intensifier are tracked with the SurgiGATE navigation system (Praxim-Medivision). Two fluoroscopic images, one acquired from anterior-posterior (AP) direction and the other from lateral-medial (LM) direction, are used for the complete procedure of planning and navigation. Both of them are calibrated with a custom-made software to recover their projection geometry and to co-register them to a common patient reference coordinate system, which is established by attaching an opto-electronically trackable dynamic reference base (DRB) on the operated vertebra. A bi-planar landmark reconstruction method is used to acquire deep-seated anatomical landmarks such that an intraoperative planning of graft bed can be interactively done. Finally, surgical actions such as the placement of the stabilization devices and the formation of the graft bed using a custom-made chisel are visualized to the surgeon by superimposing virtual instrument representations onto the acquired images. The distance between the instrument tip and each wall of the planned graft bed are calculated on the fly and presented to the surgeon so that the surgeon could formalize the graft bed exactly according to his/her plan. RESULTS: Laboratory studies on phantom and on 27 plastic vertebras demonstrate the high precision of the proposed navigation system. Compared with CT-based measurement, a mean error of 1.0 mm with a standard deviation of 0.1 mm was found. CONCLUSIONS: The proposed computer assisted, fluoroscopy-based planning and navigation system promises to increase the accuracy and reliability of minimally invasive ventral spondylodesis of thoracolumbar fractures.
Resumo:
While the benefits of intensified insulin treatment in insulin-dependent (Type 1) diabetes mellitus (IDDM) are well recognized, the risks have not been comprehensively characterized. We examined the risk of severe hypoglycaemia, ketoacidosis, and death in a meta-analysis of randomized controlled trials. The MEDLINE database, reference lists, and specialist journals were searched electronically or by hand to identify relevant studies with at least 6 months of follow-up and the monitoring of glycaemia by glycosylated haemoglobin measurements. Logistic regression was used for calculation of combined odds ratios and 95% confidence intervals (95% CI). The influence of covariates was examined by including covariate-by-treatment interaction terms. Methodological study quality was assessed and sensitivity analyses were performed. Fourteen trials were identified. These contributed 16 comparisons with 1028 patients allocated to intensified and 1039 allocated to conventional treatment. A total of 846 patients suffered at least one episode of severe hypoglycaemia, 175 patients experienced ketoacidosis and 26 patients died. The combined odds ratio (95% CI) for hypoglycaemia was 2.99 (2.45-3.64), for ketoacidosis 1.74 (1.27-2.38) and for death from all causes 1.40 (0.65-3.01). The risk of severe hypoglycaemia was determined by the degree of normalization of glycaemia achieved (p=0.005 for interaction term), with the results from the Diabetes Control and Complications Trial (DCCT) in line with the other trials. Ketoacidosis risk depended on the type of intensified treatment used. Odds ratios (95% CI) were 7.20 (2.95-17.58) for exclusive use of pumps, 1.13 (0.15-8.35) for multiple daily injections and 1.28 (0.90-1.83) for trials offering a choice between the two (p = 0.004 for interaction). Mortality was significantly (p = 0.007) increased for causes potentially associated with acute complications (7 vs 0 deaths, 5 deaths attributed to ketoacidosis, and 2 sudden deaths), and non-significantly (p = 0.16) decreased for macrovascular causes (3 vs 8 deaths). We conclude that there is a substantial risk of severe adverse effects associated with intensified insulin treatment. Mortality from acute metabolic causes is increased; however, this is largely counterbalanced by a reduction in cardiovascular mortality. The excess of severe hypoglycemia in the DCCT is not exceptional. Multiple daily injection schemes may be safer than treatment with insulin pumps.
Resumo:
Background Patients' health related quality of life (HRQoL) has rarely been systematically monitored in general practice. Electronic tools and practice training might facilitate the routine application of HRQoL questionnaires. Thorough piloting of innovative procedures is strongly recommended before the conduction of large-scale studies. Therefore, we aimed to assess i) the feasibility and acceptance of HRQoL assessment using tablet computers in general practice, ii) the perceived practical utility of HRQoL results and iii) to identify possible barriers hindering wider application of this approach. Methods Two HRQoL questionnaires (St. George's Respiratory Questionnaire SGRQ and EORTC QLQ-C30) were electronically presented on portable tablet computers. Wireless network (WLAN) integration into practice computer systems of 14 German general practices with varying infrastructure allowed automatic data exchange and the generation of a printout or a PDF file. General practitioners (GPs) and practice assistants were trained in a 1-hour course, after which they could invite patients with chronic diseases to fill in the electronic questionnaire during their waiting time. We surveyed patients, practice assistants and GPs regarding their acceptance of this tool in semi-structured telephone interviews. The number of assessments, HRQoL results and interview responses were analysed using quantitative and qualitative methods. Results Over the course of 1 year, 523 patients filled in the electronic questionnaires (1–5 times; 664 total assessments). On average, results showed specific HRQoL impairments, e.g. with respect to fatigue, pain and sleep disturbances. The number of electronic assessments varied substantially between practices. A total of 280 patients, 27 practice assistants and 17 GPs participated in the telephone interviews. Almost all GPs (16/17 = 94%; 95% CI = 73–99%), most practice assistants (19/27 = 70%; 95% CI = 50–86%) and the majority of patients (240/280 = 86%; 95% CI = 82–91%) indicated that they would welcome the use of electronic HRQoL questionnaires in the future. GPs mentioned availability of local health services (e.g. supportive, physiotherapy) (mean: 9.4 ± 1.0 SD; scale: 1 – 10), sufficient extra time (8.9 ± 1.5) and easy interpretation of HRQoL results (8.6 ± 1.6) as the most important prerequisites for their use. They believed HRQoL assessment facilitated both communication and follow up of patients' conditions. Practice assistants emphasised that this process demonstrated an extra commitment to patient centred care; patients viewed it as a tool, which contributed to the physicians' understanding of their personal condition and circumstances. Conclusion This pilot study indicates that electronic HRQoL assessment is technically feasible in general practices. It can provide clinically significant information, which can either be used in the consultation for routine care, or for research purposes. While GPs, practice assistants and patients were generally positive about the electronic procedure, several barriers (e.g. practices' lack of time and routine in HRQoL assessment) need to be overcome to enable broader application of electronic questionnaires in every day medical practice.
Resumo:
Background: Emotional processing in essential hypertension beyond self-report questionnaire has hardly been investigated. The aim of this study is to examine associations between hypertension status and recognition of facial affect. Methods: 25 healthy, non-smoking, medication-free men including 13 hypertensive subjects aged between 20 and 65 years completed a computer-based task in order to examine sensitivity of recognition of facial affect. Neutral faces gradually changed to a specific emotion in a pseudo-continuous manner. Slides of the six basic emotions (fear, sadness, disgust, happiness, anger, surprise) were chosen from the „NimStim Set“. Pictures of three female and three male faces were electronically morphed in 1% steps of intensity from 0% to 100% (36 sets of faces with 100 pictures each). Each picture of a set was presented for one second, ranging from 0% to 100% of intensity. Participants were instructed to press a stop button as soon as they recognized the expression of the face. After stopping a forced choice between the six basic emotions was required. As dependent variables, we recorded the emotion intensity at which the presentation was stopped and the number of errors (error rate). Recognition sensitivity was calculated as emotion intensity of correctly identified emotions. Results: Mean arterial pressure was associated with a significantly increased recognition sensitivity of facial affect for the emotion anger (ß = - .43, p = 0.03*, Δ R2= .110). There was no association with the emotions fear, sadness, disgust, happiness, and surprise (p’s > .0.41). Mean arterial pressure did not relate to the mean number of errors for any of the facial emotions. Conclusions: Our findings suggest that an increased blood pressure is associated with increased recognition sensitivity of facial affect for the emotion anger, if a face shows anger. Hypertensives perceive facial anger expression faster than normotensives, if anger is shown.
Resumo:
Objective. To identify current outpatient parenteral antibiotic therapy practice patterns and complications. Methods. We administered an 11-question survey to adult infectious disease physicians participating in the Emerging Infections Network (EIN), a Centers for Disease Control and Prevention-sponsored sentinel event surveillance network in North America. The survey was distributed electronically or via facsimile in November and December 2012. Respondent demographic characteristics were obtained from EIN enrollment data. Results. Overall, 555 (44.6%) of EIN members responded to the survey, with 450 (81%) indicating that they treated 1 or more patients with outpatient parenteral antimicrobial therapy (OPAT) during an average month. Infectious diseases consultation was reported to be required for a patient to be discharged with OPAT by 99 respondents (22%). Inpatient (282 [63%] of 449) and outpatient (232 [52%] of 449) infectious diseases physicians were frequently identified as being responsible for monitoring laboratory results. Only 26% (118 of 448) had dedicated OPAT teams at their clinical site. Few infectious diseases physicians have systems to track errors, adverse events, or "near misses" associated with OPAT (97 [22%] of 449). OPAT-associated complications were perceived to be rare. Among respondents, 80% reported line occlusion or clotting as the most common complication (occurring in 6% of patients or more), followed by nephrotoxicity and rash (each reported by 61%). Weekly laboratory monitoring of patients who received vancomycin was reported by 77% of respondents (343 of 445), whereas 19% of respondents (84 of 445) reported twice weekly laboratory monitoring for these patients. Conclusions. Although use of OPAT is common, there is significant variation in practice patterns. More uniform OPAT practices may enhance patient safety.
Resumo:
OBJECTIVES Accurate trial reporting facilitates evaluation and better use of study results. The objective of this article is to investigate the quality of reporting of randomized controlled trials (RCTs) in leading orthodontic journals, and to explore potential predictors of improved reporting. METHODS The 50 most recent issues of 4 leading orthodontic journals until November 2013 were electronically searched. Reporting quality assessment was conducted using the modified CONSORT statement checklist. The relationship between potential predictors and the modified CONSORT score was assessed using linear regression modeling. RESULTS 128 RCTs were identified with a mean modified CONSORT score of 68.97% (SD = 11.09). The Journal of Orthodontics (JO) ranked first in terms of completeness of reporting (modified CONSORT score 76.21%, SD = 10.1), followed by American Journal of Orthodontics and Dentofacial Orthopedics (AJODO) (73.05%, SD = 10.1). Journal of publication (AJODO: β = 10.08, 95% CI: 5.78, 14.38; JO: β = 16.82, 95% CI: 11.70, 21.94; EJO: β = 7.21, 95% CI: 2.69, 11.72 compared to Angle), year of publication (β = 0.98, 95% CI: 0.28, 1.67 for each additional year), region of authorship (Europe: β = 5.19, 95% CI: 1.30, 9.09 compared to Asia/other), statistical significance (significant: β = 3.10, 95% CI: 0.11, 6.10 compared to non-significant) and methodologist involvement (involvement: β = 5.60, 95% CI: 1.66, 9.54 compared to non-involvement) were all significant predictors of improved modified CONSORT scores in the multivariable model. Additionally, median overall Jadad score was 2 (IQR = 2) across journals, with JO (median = 3, IQR = 1) and AJODO (median = 3, IQR = 2) presenting the highest score values. CONCLUSION The reporting quality of RCTs published in leading orthodontic journals is considered suboptimal in various CONSORT areas. This may have a bearing in trial result interpretation and use in clinical decision making and evidence- based orthodontic treatment interventions.
Resumo:
PURPOSE A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. METHODS The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose-volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. RESULTS For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. CONCLUSIONS A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.
Resumo:
Additional jet activity in dijet events is measured using pp collisions at ATLAS at a centre-of-mass energy of 7 TeV, for jets reconstructed using the anti-kt algorithm with radius parameter R=0.6. This is done using variables such as the fraction of dijet events without an additional jet in the rapidity interval bounded by the dijet subsystem and correlations between the azimuthal angles of the dijets. They are presented, both with and without a veto on additional jet activity in the rapidity interval, as a function of the mean transverse momentum of the dijets and of the rapidity interval size. The double differential dijet cross section is also measured as a function of the interval size and the azimuthal angle between the dijets. These variables probe differences in the approach to resummation of large logarithms when performing QCD calculations. The data are compared to POWHEG, interfaced to the PYTHIA 8 and HERWIG parton shower generators, as well as to HEJ with and without interfacing it to the ARIADNE parton shower generator. None of the theoretical predictions agree with the data across the full phase-space considered; however, POWHEG+PYTHIA 8 and HEJ+ARIADNE are found to provide the best agreement with the data.These measurements use the full data sample collected with the ATLAS detector in 7 TeV pp collisions at the LHC and correspond to integrated luminosities of 36.1 pb−1 and 4.5 fb−1 for data collected during 2010 and 2011 respectively.
Resumo:
Double-differential dijet cross-sections measured in pp collisions at the LHC with a 7TeV centre-of-mass energy are presented as functions of dijet mass and half the rapidity separation of the two highest-pT jets. These measurements are obtained using data corresponding to an integrated luminosity of 4.5 fb−1, recorded by the ATLAS detector in 2011. The data are corrected for detector effects so that cross-sections are presented at the particle level. Cross-sections are measured up to 5TeV dijet mass using jets reconstructed with the anti-kt algorithm for values of the jet radius parameter of 0.4 and 0.6. The cross-sections are compared with next-to-leading-order perturbative QCD calculations by NLOJet++ corrected to account for non-perturbative effects. Comparisons with POWHEG predictions, using a next-to-leading-order matrix element calculation interfaced to a partonshower Monte Carlo simulation, are also shown. Electroweak effects are accounted for in both cases. The quantitative comparison of data and theoretical predictions obtained using various parameterizations of the parton distribution functions is performed using a frequentist method. In general, good agreement with data is observed for the NLOJet++ theoretical predictions when using the CT10, NNPDF2.1 and MSTW 2008 PDF sets. Disagreement is observed when using the ABM11 and HERAPDF1.5 PDF sets for some ranges of dijet mass and half the rapidity separation. An example setting a lower limit on the compositeness scale for a model of contact interactions is presented, showing that the unfolded results can be used to constrain contributions to dijet production beyond that predicted by the Standard Model.
Resumo:
Development of interfaces for sample introduction from high pressures is important for real-time online hyphenation of chromatographic and other separation devices with mass spectrometry (MS) or accelerator mass spectrometry (AMS). Momentum separators can reduce unwanted low-density gases and introduce the analyte into the vacuum. In this work, the axial jet separator, a new momentum interface, is characterized by theory and empirical optimization. The mathematical model describes the different axial penetration of the components of a jetgas mixture and explains the empirical results for injections of CO2 in helium into MS and AMS instruments. We show that the performance of the new interface is sensitive to the nozzle size, showing good qualitative agreement with the mathematical model. Smaller nozzle sizes are more preferable due to their higher inflow capacity. The CO2 transmission efficiency of the interface into a MS instrument is ~14% (CO2/helium separation factor of 2.7). The interface receives and delivers flows of ~17.5 mL/min and ~0.9 mL/min, respectively. For the interfaced AMS instrument, the ionization and overall efficiencies are 0.7-3% and 0.1-0.4%, respectively, for CO2 amounts of 4-0.6 µg C, which is only slightly lower compared to conventional systems using intermediate trapping. The ionization efficiency depends on to the carbon mass flow in the injected pulse and is suppressed at high CO2 flows. Relative to a conventional jet separator, the transmission efficiency of the axial jet separator is lower, but its performance is less sensitive to misalignments.
Resumo:
PURPOSE Digital developments have led to the opportunity to compose simulated patient models based on three-dimensional (3D) skeletal, facial, and dental imaging. The aim of this systematic review is to provide an update on the current knowledge, to report on the technical progress in the field of 3D virtual patient science, and to identify further research needs to accomplish clinical translation. MATERIALS AND METHODS Searches were performed electronically (MEDLINE and OVID) and manually up to March 2014 for studies of 3D fusion imaging to create a virtual dental patient. Inclusion criteria were limited to human studies reporting on the technical protocol for superimposition of at least two different 3D data sets and medical field of interest. RESULTS Of the 403 titles originally retrieved, 51 abstracts and, subsequently, 21 full texts were selected for review. Of the 21 full texts, 18 studies were included in the systematic review. Most of the investigations were designed as feasibility studies. Three different types of 3D data were identified for simulation: facial skeleton, extraoral soft tissue, and dentition. A total of 112 patients were investigated in the development of 3D virtual models. CONCLUSION Superimposition of data on the facial skeleton, soft tissue, and/or dentition is a feasible technique to create a virtual patient under static conditions. Three-dimensional image fusion is of interest and importance in all fields of dental medicine. Future research should focus on the real-time replication of a human head, including dynamic movements, capturing data in a single step.
Resumo:
OBJECTIVES To assess the presence of within-group comparisons with baseline in a subset of leading dental journals and to explore possible associations with a range of study characteristics including journal and study design. STUDY DESIGN AND SETTING Thirty consecutive issues of five leading dental journals were electronically searched. The conduct and reporting of statistical analysis in respect of comparisons against baseline or otherwise along with the manner of interpretation of the results were assessed. Descriptive statistics were obtained, and chi-square test and Fisher's exact were undertaken to test the association between trial characteristics and overall study interpretation. RESULTS A total of 184 studies were included with the highest proportion published in Journal of Endodontics (n = 84, 46%) and most involving a single center (n = 157, 85%). Overall, 43 studies (23%) presented interpretation of their outcomes based solely on comparisons against baseline. Inappropriate use of baseline testing was found to be less likely in interventional studies (P < 0.001). CONCLUSION Use of comparisons with baseline appears to be common among both observational and interventional research studies in dentistry. Enhanced conduct and reporting of statistical tests are required to ensure that inferences from research studies are appropriate and informative.
Resumo:
Early diagnosis of patients with compensated advanced chronic liver disease (cACLD) and portal hypertension is challenging in clinical practice. A growing amount of evidence regarding noninvasive diagnostic methods, and in particular liver stiffness measurement (LSM), suggests that these tools could be used in clinical practice and might potentially limit the use of invasive, reference diagnostic tools (HVPG measurement and endoscopy). Our panel aimed at better understanding the opinion of the Baveno faculty regarding the current practice and use of invasive and noninvasive methods in the field of screening and surveillance of varices; a specific questionnaire was electronically sent to all the faculty members. The results suggested that the experts agreed on the use of noninvasive methods to rule out/identify patients with cACLD. They also indicated that the persistence or removal of the causal agent which led to cirrhosis should guide the choice of using the shortest or the longest interval among those recommended for surveillance endoscopies. Finally, the use of noninvasive methods in these clinical scenarios was pointed out as a relevant field for future research.