22 resultados para Electron Microscope

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the long run, the widespread use of slide scanners by pathologists requires an adaptation of teaching methods in histology and cytology in order to target these new possibilities of image processing and presentation via the internet. Accordingly, we were looking for a tool with the possibility to teach microscopic anatomy, histology, and cytology of tissue samples which would be able to combine image data from light and electron microscopes independently of microscope suppliers. With the example of a section through the villus of jejunum, we describe here how to process image data from light and electron microscopes in order to get one image-stack which allows a correlation of structures from the microscopic anatomic to the cytological level. With commercially available image-presentation software that we adapted to our needs, we present here a platform which allows for the presentation of this new but also of older material independently of microscope suppliers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During postnatal growth the parenchymal septa of rat lung undergo an impressive restructuring. While immature septa are thick and contain two capillary layers, mature septa are slender and contain a single microvascular network. Using the Mercox casting technique and scanning electron microscopy, we investigated the mode and the timing of the transformation of the pulmonary capillary bed. During the third postnatal week the parenchymal septa rapidly mature to match adult morphology. Even in adult lungs, however, remnants of the immature status are present: A capillary bilayer is regularly found at the base and the tip of the septa. Our observations support the concept that reduction of intervening tissue, partial fusion of the two capillary networks, and preferential growth lead to the mature vascular arrangement. The fact that true mature interalveolar septa show a denser capillary network than alveolar walls abutting onto pleura, bronchi, or larger vessels is consonant with the fusion theory. Towards the nonparenchyma, the capillary network surrounding every airspace had no counterpart to fuse with. From quantitative data it can be calculated that owing to lung growth, mesh size should increase more than four times between birth and adult age. The adult lung network, however, is denser than the one in young animals. This means that new meshes must be added during growth. We propose that small holes observed in sheet-like regions of the microvasculature enlarge to form new capillary meshes. With this mechanism of in-itself or intussusceptional growth, sprouting of individual capillary segments to increase network size is no longer needed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Lamellar bodies are the storage sites for lung surfactant within type II alveolar epithelial cells. The structure-function models of lamellar bodies are based on microscopic analyses of chemically fixed tissue. Despite available alternative fixation methods that are less prone to artifacts, such as cryofixation by high-pressure freezing, the nature of the lung, being mostly air filled, makes it difficult to take advantage of these improved methods. In this paper, we propose a new approach and show for the first time the ultrastructure of intracellular lamellar bodies based on cryo-electron microscopy of vitreous sections in the range of nanometer resolution. Thus, unspoiled by chemical fixation, dehydration and contrasting agents, a close to native structure is revealed. Our approach uses perfluorocarbon to substitute the air in the alveoli. Lung tissue was subsequently high-pressure frozen, cryosectioned and observed in a cryo-electron microscope. The lamellar bodies clearly show a tight lamellar morphology. The periodicity of these lamellae was 7.3 nm. Lamellar bifurcations were observed in our cryosections. The technical approach described in this paper allows the examination of the native cellular ultrastructure of the surfactant system under near in vivo conditions, and therefore opens up prospectives for scrutinizing various theories of lamellar body biogenesis, exocytosis and recycling.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

INTRODUCTION: The ultrastructure of venous valves and walls in chronic venous disease was investigated. METHODS: Consecutive patients were categorised into one of three groups (group A: patients with C1 venous disease in accordance with CEAP (Clinical severity, Etiology, Anatomy, Pathophysiology); group B: C2 and C3; group C: C4, C5 and C6). The terminal or preterminal valve and adjacent vessel wall was harvested from the great saphenous vein. Sections were examined with a transmission electron microscope. The volumes of elastin and of collagen per unit surface area of valve were assessed, as well as the surface endothelium of valve and vessel wall. RESULTS: The study population consisted of 17 patients. The elastin ratio was analysed by means of stereology. Mean values were: in group A, 0.45 μm3/m2; in group B, 0.67 μm3/m2; in group C, 0.97 μm3/m2. The ratio was similar for collagen (A, 15.7 μm3/m2; B, 26.8 μm3/m2; C, 30.1 μm3/m2). Surface analysis of the valve endothelium and the adjacent vessel wall endothelium showed a trend towards increasing damage with more severe disease. CONCLUSIONS: With progression of venous disease, the valve elastin content, assessed morphologically, seems to increase, and the endothelium of the venous valve and the vein wall tend to show more damage.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A transmission electron microscope (TEM) accessory, the energy filter, enables the establishment of a method for elemental microanalysis, the electron energy-loss spectroscopy (EELS). In conventional TEM, unscattered, elastic, and inelastic scattered electrons contribute to image information. Energy-filtering TEM (EFTEM) allows elemental analysis at the ultrastructural level by using selected inelastic scattered electrons. EELS is an excellent method for elemental microanalysis and nanoanalysis with good sensitivity and accuracy. However, it is a complex method whose potential is seldom completely exploited, especially for biological specimens. In addition to spectral analysis, parallel-EELS, we present two different imaging techniques in this chapter, namely electron spectroscopic imaging (ESI) and image-EELS. We aim to introduce these techniques in this chapter with the elemental microanalysis of titanium. Ultrafine, 22-nm titanium dioxide particles are used in an inhalation study in rats to investigate the distribution of nanoparticles in lung tissue.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Water-containing biological material cannot withstand the vacuum of the transmission electron microscope. The classical solution to this problem has been to dehydrate chemically fixed biological samples and then embed them in resin. During such treatment, the bacterial nucleoid is especially prone to aggregation, which affects its global shape and fine structure. Initial attempts to deal with aggregation by optimizing chemical fixation yielded contradictory results. Two decades ago, the situation improved with the introduction of freeze-substitution. This method is based on dehydration of unfixed cryo-immobilized samples at low temperature, which substantially reduces aggregation. As a result, the global shape of the nucleoid can be fairly well defined. Overall, in actively growing bacteria, the nucleoids are dispersed and "coralline" but become more confined when growth ceases. However, it is usually impossible to determine the molecular arrangement of DNA in the nucleoids of freeze-substituted bacteria because crystallization and the subsequent removal of water during substitution result in unavoidable distortions at the ultrastructural level. Recently, cryo-electron microscopy of vitreous sections has enabled the fully hydrated bacterial nucleoid to be studied close to the native state. Such studies have revealed aspects of bacterial nucleoid organization that are not preserved by freeze-substitution, including locally parallel or twisted bundles of DNA filaments, which are more frequently observed once bacterial growth has stopped, whereas in actively growing bacteria, the DNA is seen to be in a mostly disordered pattern.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cryoultramicrotomy allows the sectioning of vitrified biological samples. These biological samples are preserved at the atomic level and represent the real structure at the moment of freezing. Cryoultramicrotomy produces ultra-thin cryosections that are investigated in a cryoelectron microscope. The necessity of working during the whole preparation at temperatures less than −140°C results in some difficulties, including the cryosection transfer from the knife-edge to the electron microscropy grid; the grid handling in the cryochamber and the grid transfer into the cryoholder of the electron microscope. Furthermore, ice crystal contamination (from air humidity) can obscure the structures of interest in the sections. It is mainly know-how and experience that will prevent the contamination of ice crystals and the recrystallization of the sections during the manipulations. Here, we describe the tips, tricks, the tools, and methods that help to overcome these burdens and pave the path for successful cryoultramicrotomy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to evaluate the cavitation rate of proximal caries using different magnification aids in vitro. METHODS: Radiographs of 285 extracted teeth were taken and the proximal surfaces were graded to the criteria R0 (no radiolucency), R1 (radiolucency confined to the outer half of enamel), R2 (inner half of enamel) and R3 (outer half of dentin). Subsequently, the proximal surfaces were checked for the presence of cavitations with the naked eye (NE), and by using 4.3 x magnification eyeglasses (ME), a stereo microscope (SM, 10x), or a scanning electron microscope (SEM, up to 2000 x magnification). RESULTS: In surfaces with R3 caries, cavitations were visible in 56 of 59 cases with the naked eye. When using SEM, all surfaces revealed cavitations (100%). Regarding the surfaces with R2 lesion, 36 of 46 cases showed cavitations (NE); the corresponding values were 39/46 (ME), 41/46 (SM), and 46/46 (SEM); in the latter, in most cases deep defects could be observed. With regard to R1 lesions, 36/60 (NE), 43/60 (ME), 45/60 (SM), and 58/60 (SEM) cases revealed cavitations. A breakdown of radiographically sound surfaces (R0) was present in some 10% of the examined surfaces (24/261, NE; 33/261, SEM). CONCLUSIONS: Cavitations (defined as breakdown of the surface) are present in significantly more cases than previously reported. This might be an explanation why even small radiolucencies tend to progress, albeit slowly. Thus, close follow-ups should strongly be recommended when considering a preventive treatment regimen with small radiolucencies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Root canal obliterations may pose esthetic and clinical problems or may even be a risk factor for tooth survival. Microcalcifications in the pulp can be so extensive that the entire root canal system becomes obliterated. Since bone sialoprotein (BSP) and osteopontin (OPN) are involved in both physiological and pathological mineralization processes, our hypothesis was that these two bone-related noncollagenous proteins are present in microcalcifications of the pulp. The purpose of this study was, therefore, to characterize the nature of microcalcifications in the pulp of aged human teeth. Methods: From a large collection of human teeth, 10 were found to exhibit pulpal microcalcifications. The teeth were extracted for periodontal reasons from 39-60 year old patients. After fixation in aldehydes and decalcification, teeth were processed for embedding in LR White resin for analysis in the light and transmission electron microscope. For the detection of BSP and OPN, post-embedding high resolution immunocytochemistry was applied. Results: The microcalcifications were round or elongated, occasionally coalescing, and intensely stained with toluidine blue. Collagen fibrils were found in most but not all microcalcifications. All microcalcifications were immunoreactive for both antibodies and showed an identical labeling pattern. Gold particle labeling was extensively found throughout the interfibrillar ground substance of the microcalcifications, whereas the dentin matrix lacked immunolabeling. Conclusion: BSP and OPN appear to be major matrix constituents of pulp microcalcifications and may thus, like in other mineralized tissues, be involved in their mineralization process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tubulo-interstitial fibrosis is a constant feature of chronic renal failure and it is suspected to contribute importantly to the deterioration of renal function. In the fibrotic kidney there exists, besides normal fibroblasts, a large population of myofibroblasts, which are supposedly responsible for the increased production of intercellular matrix. It has been proposed that myofibroblasts in chronic renal failure originate from the transformation of tubular cells via epithelial-mesenchymal transition (EMT) or from infiltration by bone marrow-derived precursors. Little attention has been paid to the possibility of a transformation of resident fibroblasts into myofibroblasts in renal fibrosis. Therefore we examined the fate of resident fibroblasts in the initial phase of renal fibrosis in the classical model of unilateral ureter obstruction (UUO) in the rat. Rats were perfusion-fixed on days 1, 2, 3 and 4 after ligature of the right ureter. Starting from 1 day of UUO an increasing expression of alpha-smooth muscle actin (alphaSMA) in resident fibroblasts was revealed by immunofluorescence and confirmed by the observation of bundles of microfilaments and webs of intermediate filaments in the electron microscope. Inversely, there was a decreased expression of 5'-nucleotidase (5'NT), a marker of renal cortical fibroblasts. The RER became more voluminous, suggesting an increased synthesis of matrix. Intercellular junctions, a characteristic feature of myofibroblasts, became more frequent. The mitotic activity in fibroblasts was strongly increased. Renal tubules underwent severe regressive changes but the cells retained their epithelial characteristics and there was no sign of EMT. In conclusion, after ureter ligature, resident peritubular fibroblasts proliferated and they showed progressive alterations, suggesting a transformation in myofibroblasts. Thus the resident fibroblasts likely play a central role in fibrosis in that model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ageing societies suffer from an increasing incidence of bone fractures. Bone strength depends on the amount of mineral measured by clinical densitometry, but also on the micromechanical properties of the hierarchical organization of bone. Here, we investigate the mechanical response under monotonic and cyclic compression of both single osteonal lamellae and macroscopic samples containing numerous osteons. Micropillar compression tests in a scanning electron microscope, microindentation and macroscopic compression tests were performed on dry ovine bone to identify the elastic modulus, yield stress, plastic deformation, damage accumulation and failure mechanisms. We found that isolated lamellae exhibit a plastic behaviour, with higher yield stress and ductility but no damage. In agreement with a proposed rheological model, these experiments illustrate a transition from a ductile mechanical behaviour of bone at the microscale to a quasi-brittle response driven by the growth of cracks along interfaces or in the vicinity of pores at the macroscale.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To investigate how the modulus of elasticity of resin composites influences marginal quality in restorations submitted to thermocyclic and mechanical loading. METHODS Charisma, Filtek Supreme XTE and Grandio were selected as they were found to possess different moduli of elasticity but quite similar polymerization contraction. MOD cavities (n=30) were prepared in extracted premolars, restored and then subjected to thermocyclic and mechanical loading. Marginal quality of the restorations before and after loading was analyzed on epoxy replicas under a scanning electron microscope. The percentage of gap-free margins and occurrence of paramarginal fractures were registered. Modulus of elasticity and polymerization contraction were analyzed with parametric and margins with nonparametric ANOVA and post hoc Tukey HSD or Wilcoxon rank-sum tests, respectively. The number of paramarginal fractures was analyzed with exact Fisher tests (α=0.05). RESULTS Grandio demonstrated significantly more gap-free enamel margins than Charisma and Filtek Supreme XTE, before and after loading (p<0.01), whereas there was no difference between Charisma and Filtek Supreme XTE (p>0.05). No significant effect of resin composite (p=0.81) on the quality of dentine margins was observed, before or after loading. Deterioration of all margins was evident after loading (p<0.0001). More paramarginal enamel fractures were observed after loading in teeth restored with Grandio when compared to Charisma (p=0.008). CONCLUSIONS The resin composite with the highest modulus of elasticity resulted in the highest number of gap-free enamel margins but with an increased incidence of paramarginal enamel fractures. CLINICAL SIGNIFICANCE The results from this study suggest that the marginal quality of restorations can be improved by the selection of a resin composite with modulus of elasticity close to that of dentine, although an increase in paramarginal enamel fractures can result as a consequence.