7 resultados para Electron—beam gun evaporation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case involving a spring-gun device (muzzleloader) loaded solely with gunpowder, installed next to shoes to prevent the neighbors' puppy from removing them. The booby trap was triggered by the 15-year-old dog-owners son when he tried to put the shoes out of the reach of the puppy. The boy suffered second degree superficial burns located mainly at the dorsal side of the right hand and fingers. To estimate the danger of the used weapon, several tests were undertaken on soap blocks from different distances and with different loads of black powder. The particle density per mm and the depth of black powder tattooing in the soap was compared with the boy's injuries, and found conclusive with the gun-owners statement regarding the loading of the weapon. Furthermore, our experiments indicated that the gunpowder load involved was not able to inflict permanent damage, not even to the eyes, at the here estimated firing distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: In 2001 a prototype of a gun to apply bioabsorbable tacks in cranio-facial surgery has been developed. METHODS: From May 2001 to May 2002 this device has been used in the University Hospital of Innsbruck (Austria) for different cranioplasty procedures, in 34 children, showing its reliability for cranio-facial bone fixation. The children were affected by isolated craniosynostosis or by syndromical synostosis (Apert, Crouzon) and in a case of benign tumor of the parietal skull vault. The range of age, at the time of surgery, was between 3 months and 204 months of age. Bone segments were fixed using self-reinforced polylactide plates and tacks. RESULTS: Firm fixation was obtained intra-operatively and the operative time was reduced about 25-30 minutes as compared to use of plates and screws. This device has just one limitation in its own spring force: sometimes the bone thinner than 1 mm has been broken applying the tacks. CONCLUSION: After the first-year's experience it is possible to confirm that this device reduces, in selected cases, operative time, blood loss, risk of infection and, as a result, the costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Backspatter from wounds caused by contact shots against a biological target had before been shown to be propelled into firearms' barrels where they can persist and be retrieved from as relevant forensic evidence. Herein, that insight was applied to the investigation of a case of multiple familial homicide with a firearm. Samples of backspatter were collected from the firearm using DNA-free swabs. DNA was extracted from the swabs, and 16 STR systems were PCR-amplified to generate DNA profiles of all victims shot by the firearm. The quality of the resulting DNA profiles was sufficient to exclude the perpetrator as donor and to differentiate the three closely related victims thereby proving that all three victims had been shot by the same firearm from very close or contact distance. A key insight gained from this case was that not only a firearms' barrel inside but other inner surfaces may be charged with profilable DNA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The development of metabolic alkalosis was described recently in patients with hypernatremia. However, the causes for this remain unknown. The current study serves to clarify whether metabolic alkalosis develops in vitro after removal of free water from plasma and whether this can be predicted by a mathematical model. MATERIALS AND METHODS Ten serum samples of healthy humans were dehydrated by 29 % by vacuum centrifugation corresponding to an increase of the contained concentrations by 41 %. Constant partial pressure of carbon dioxide at 40 mmHg was simulated by mathematical correction of pH [pH(40)]. Metabolic acid-base state was assessed by Gilfix' base excess subsets. Changes of acid-base state were predicted by the physical-chemical model according to Watson. RESULTS Evaporation increased serum sodium from 141 (140-142) to 200 (197-203) mmol/L, i.e., severe hypernatremia developed. Acid-base analyses before and after serum concentration showed metabolic alkalosis with alkalemia: pH(40): 7.43 (7.41 to 7.45) vs 7.53 (7.51 to 7.55), p = 0.0051; base excess: 1.9 (0.7 to 3.6) vs 10.0 (8.2 to 11.8), p = 0.0051; base excess of free water: 0.0 (- 0.2 to 0.3) vs 17.7 (16.8 to 18.6), p = 0.0051. The acidifying effects of evaporation, including hyperalbuminemic acidosis, were beneath the alkalinizing ones. Measured and predicted acid-base changes due to serum evaporation agreed well. CONCLUSIONS Evaporation of water from serum causes concentrational alkalosis in vitro, with good agreement between measured and predicted acid-base values. At least part of the metabolic alkalosis accompanying hypernatremia is independent of renal function.