7 resultados para Electromechanical

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY OBJECTIVE To determine the effectiveness of an esophageal doppler device to non-invasively detect experimental pseudo-electromechanical dissociation (pseudo-EMD). DESIGN Prospective, controlled, laboratory investigation using an asphyxial canine cardiac arrest model and a newly-developed esophageal flat-flow probe doppler unit. INTERVENTIONS Mongrel dogs (20) were instrumented for hemodynamic monitoring. The esophageal doppler probe was placed in the distal esophagus of each animal. Electromechanical dissociation (EMD) was induced by clamping the endotracheal tube. MEASUREMENTS AND MAIN RESULTS A period of pseudo-EMD was defined as the time where cardiac contractility was present, measured by a micromanometer tipped thoracic aortic catheter, without concurrent femoral pulses by palpation. The pseudo-EMD period could be produced consistently in all 20 animals. The characteristic doppler flow sounds were easily heard using the esophageal device in all animals. The time from endotracheal tube clamping until loss of femoral pulses was 622 +/- 96 s; until loss of radial artery doppler signals was 616 +/- 92 s; until loss of esophageal doppler signals was 728 +/- 88 s; and until loss of aortic fluctuations by thoracic aortic catheter was 728 +/- 82 s. The times to loss of esophageal doppler sounds and loss of aortic fluctuations were not significantly different. However, they were significantly longer than the time to loss of femoral pulses (P < 0.02). CONCLUSIONS The canine asphyxial EMD model can be used for short experimental studies of pseudo-EMD. Pseudo-EMD can be consistently and non-invasively detected with this esophageal doppler device. The device is as reliable as a micromanometer tipped aortic arch catheter in detecting pseudo-EMD. The doppler device could potentially be useful in improving recognition of near cardiac arrest in pre-hospital and emergency department settings. Further research on the utility of this device in other models of low-flow states should be performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Hyponatremia is the most common electrolyte disorder in hospitalized patients and is known to be associated with increased mortality. The administration of antegrade single-shot, up to two liters, histidine-tryptophane-ketoglutarate (HTK) solution for adequate electromechanical cardiac arrest and myocardial preservation during minimally invasive aortic valve replacement (MIAVR) is a standard procedure. We aimed to determine the impact of HTK infusion on electrolyte and acid–base balance. Methods In this retrospective analysis we reviewed data on patient characteristics, type of surgery, arterial blood gas analysis during surgery and intra-/postoperative laboratory results of patients receiving surgery for MIAVR at a large tertiary care university hospital. Results A total of 25 patients were included in the study. All patients were normonatremic at start of surgery. All patients developed hyponatremia after administration of HTK solution with a significant drop of serum sodium of 15 mmol/L (p < 0.01). Measured osmolality did not change during all times of surgery compared to start of surgery (p = 0.28 – p = 0.79), indicating isotonic hyponatremia. After administration of HTK solution pH fell significantly due to development of metabolic acidosis. Conclusions Acute hyponatremia during cardioplegia with HTK solution is isotonic and should probably not be corrected without presence of hypotonicity as confirmed by measurement of serum osmolality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Focal ectopic activity in cardiac tissue is a key factor in the initiation and perpetuation of tachyarrhythmias. Because myofibroblasts as present in fibrotic remodeled myocardia and infarct scars depolarize cardiomyocytes by heterocellular electrotonic interactions via gap junctions in vitro, we investigated using strands of cultured ventricular cardiomyocytes coated with myofibroblasts, whether this interaction might give rise to depolarization-induced abnormal automaticity. Whereas uncoated cardiomyocyte strands were invariably quiescent, myofibroblasts induced synchronized spontaneous activity in a density dependent manner. Activations appeared at spatial myofibroblast densities >15.7% and involved more than 80% of the preparations at myofibroblast densities of 50%. Spontaneous activity was based on depolarization-induced automaticity as evidenced by: (1) suppression of activity by the sarcolemmal K(ATP) channel opener P-1075; (2) induction of activity in current-clamped single cardiomyocytes undergoing depolarization to potentials similar to those induced by myofibroblasts in cardiomyocyte strands; and (3) induction of spontaneous activity in cardiomyocyte strands coated with connexin 43 transfected Hela cells but not with communication deficient HeLa wild-type cells. Apart from unveiling the mechanism underlying the hallmark of monolayer cultures of cardiomyocytes, ie, spontaneous electromechanical activity, these findings open the perspective that myofibroblasts present in structurally remodeled myocardia following pressure overload and infarction might contribute to arrhythmogenesis by induction of ectopic activity.