1 resultado para Electrocardiography - Methods

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Paroxysmal atrial fibrillation (PAF) often remains undiagnosed. Long-term surface ECG is used for screening, but has limitations. Esophageal ECG (eECG) allows recording high quality atrial signals, which were used to identify markers for PAF. METHODS In 50 patients (25 patients with PAF; 25 controls) an eECG and surface ECG was recorded simultaneously. Partially A-V blocked atrial runs (PBARs) were quantified, atrial signal duration in eECG was measured. RESULTS eECG revealed 1.8‰ of atrial premature beats in patients with known PAF to be PBARs with a median duration of 853ms (interquartile range (IQR) 813-1836ms) and a median atrial cycle length of 366ms (IQR 282-432ms). Even during a short recording duration of 2.1h (IQR 1.2-17.2h), PBARs occurred in 20% of PAF patients but not in controls (p=0.05). Left atrial signal duration was predictive for PAF (72% sensitivity, 80% specificity). CONCLUSIONS eECG reveals partially blocked atrial runs and prolonged left atrial signal duration - two novel surrogate markers for PAF.