61 resultados para Electrical-stimulation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the anti-nociceptive activity of ketamine and isoflurane in horses using a limb withdrawal reflex (WR) model. Single and repeated stimulations were applied to the digital nerve of the left forelimb in ponies anaesthetised with isoflurane before, during and after intravenous administration of racemic ketamine. Surface electromyographic activity was recorded from the deltoid muscle. Higher stimulation intensity was required to evoke a reflex during ketamine administration. Furthermore, the amplitudes of response to stimulations were significantly and dose-dependently depressed and a flattening of the stimulus-response curves was observed. The reflex activity recovered partially once the ketamine infusion finished. The results demonstrated that the limb WR can be used to quantify the temporal effect of ketamine on the sensory-motor processing in ponies anaesthetised with isoflurane.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to quantify the effects of isoflurane at approximately the minimum alveolar concentration (peri-MAC) on the temporal summation (TS) of reflex activity in ponies. TS was evoked by repeated electrical stimulations applied at 5 Hz for 2 s on the digital nerve of the left forelimb of seven ponies. Surface electromyographic activity was recorded from the deltoid and common digital extensor muscles. TS thresholds and amplitude of response to stimulations of increasing intensities were assessed during anaesthesia at 0.85, 0.95 and 1.05 times the individual MAC, and after anaesthesia in standing animals. Under isoflurane anaesthesia, TS thresholds increased significantly in a concentration-dependent fashion and at each isoflurane MAC, the responses increased significantly for increasing stimulation intensities. A concentration-dependent depression of evoked reflexes with a reduction in the slopes of the stimulus-response function was observed for both muscles. The results demonstrated that with this model it is possible to describe and quantify the effects of anaesthetics on spinal sensory-motor processing in ponies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To investigate effects of isoflurane at approximately the minimum alveolar concentration (MAC) on the nociceptive withdrawal reflex (NWR) of the forelimb of ponies as a method for quantifying anesthetic potency. ANIMALS: 7 healthy adult Shetland ponies. PROCEDURE: Individual MAC (iMAC) for isoflurane was determined for each pony. Then, effects of isoflurane administered at 0.85, 0.95, and 1.05 iMAC on the NWR were assessed. At each concentration, the NWR threshold was defined electromyographically for the common digital extensor and deltoid muscles by stimulating the digital nerve; additional electrical stimulations (3, 5, 10, 20, 30, and 40 mA) were delivered, and the evoked activity was recorded and analyzed. After the end of anesthesia, the NWR threshold was assessed in standing ponies. RESULTS: Mean +/- SD MAC of isoflurane was 1.0 +/- 0.2%. The NWR thresholds for both muscles increased significantly in a concentration-dependent manner during anesthesia, whereas they decreased in awake ponies. Significantly higher thresholds were found for the deltoid muscle, compared with thresholds for the common digital extensor muscle, in anesthetized ponies. At each iMAC tested, amplitudes of the reflex responses from both muscles increased as stimulus intensities increased from 3 to 40 mA. A concentration-dependent depression of evoked reflexes with reduction in slopes of the stimulus-response functions was detected. CONCLUSIONS AND CLINICAL RELEVANCE: Anesthetic-induced changes in sensory-motor processing in ponies anesthetized with isoflurane at concentrations of approximately 1.0 MAC can be detected by assessment of NWR. This method will permit comparison of effects of inhaled anesthetics or anesthetic combinations on spinal processing in equids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine the minimum alveolar concentration (MAC) of isoflurane in Shetland ponies using a sequence of three different supramaximal noxious stimulations at each tested concentration of isoflurane rather than a single stimulation. STUDY DESIGN: Prospective, experimental trial. ANIMALS: Seven 4-year-old, gelding Shetland ponies. METHODS: The MAC of isoflurane was determined for each pony. Three different modes of electrical stimulation were applied consecutively (2 minute intervals): two using constant voltage (90 V) on the gingiva via needle- (CVneedle) or surface-electrodes (CVsurface) and one using constant current (CC; 40 mA) via surface electrodes applied to the skin over the digital nerve. The ability to clearly interpret the responses as positive, the latency of the evoked responses and the inter-electrode resistance were recorded for each stimulus. RESULTS: Individual isoflurane MAC (%) values ranged from 0.60 to 1.17 with a mean (+/-SD) of 0.97 (+/-0.17). The responses were more clearly interpreted with CC, but did not reach statistical significance. The CVsurface mode produced responses with a longer delay. The CVneedle mode was accompanied by variable inter-electrode resistances resulting in uncontrolled stimulus intensity. At 0.9 MAC, the third stimulation induced more positive responses than the first stimulation, independent of the mode of stimulation used. CONCLUSIONS: The MAC of isoflurane in the Shetland ponies was lower than expected with considerable variability among individuals. Constant current surface electrode stimulations were the most repeatable. A summation over the sequence of three supramaximal stimulations was observed around 0.9 MAC. CLINICAL RELEVANCE: The possibility that Shetland ponies require less isoflurane than horses needs further investigation. Constant current surface-electrode stimulations were the most repeatable. Repetitive supramaximal stimuli may have evoked movements at isoflurane concentrations that provide immobility when single supramaximal stimulation was applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To study the clinical outcome in hippocampal deep brain stimulation (DBS) for the treatment of patients with refractory mesial temporal lobe epilepsy (MTLE) according to the electrode location. METHODS Eight MTLE patients implanted in the hippocampus and stimulated with high-frequency DBS were included in this study. Five underwent invasive recordings with depth electrodes to localize ictal onset zone prior to chronic DBS. Position of the active contacts of the electrode was calculated on postoperative imaging. The distances to the ictal onset zone were measured as well as atlas-based hippocampus structures impacted by stimulation were identified. Both were correlated with seizure frequency reduction. RESULTS The distances between active electrode location and estimated ictal onset zone were 11±4.3 or 9.1±2.3mm for patients with a >50% or <50% reduction in seizure frequency. In patients (N=6) showing a >50% seizure frequency reduction, 100% had the active contacts located <3mm from the subiculum (p<0.05). The 2 non-responders patients were stimulated on contacts located >3mm to the subiculum. CONCLUSION Decrease of epileptogenic activity induced by hippocampal DBS in refractory MTLE: (1) seems not directly associated with the vicinity of active electrode to the ictal focus determined by invasive recordings; (2) might be obtained through the neuromodulation of the subiculum.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recent studies have shown that the nociceptive withdrawal reflex threshold (NWR-T) and the electrical pain threshold (EP-T) are reliable measures in pain-free populations. However, it is necessary to investigate the reliability of these measures in patients with chronic pain in order to translate these techniques from laboratory to clinic. The aims of this study were to determine the test-retest reliability of the NWR-T and EP-T after single and repeated (temporal summation) electrical stimulation in a group of patients with chronic low back pain, and to investigate the association between the NWR-T and the EP-T. To this end, 25 patients with chronic pain participated in three identical sessions, separated by 1 week in average, in which the NWR-T and the EP-T to single and repeated stimulation were measured. Test-retest reliability was assessed using intra-class correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analysis. The association between the thresholds was assessed using the coefficient of determination (r (2)). The results showed good-to-excellent reliability for both NWR-T and EP-T in all cases, with average ICC values ranging 0.76-0.90 and average CV values ranging 12.0-17.7%. The association between thresholds was better after repeated stimulation than after single stimulation, with average r (2) values of 0.83 and 0.56, respectively. In conclusion, the NWR-T and the EP-T are reliable assessment tools for assessing the sensitivity of spinal nociceptive pathways in patients with chronic pain.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although manual and electrical stimulation are frequently used in acupuncture analgesia, studies comparing both stimulation modalities are contradictory. This blinded, placebo-controlled cross-over study investigates effects of brief manual and electrical acupuncture stimulation on pressure pain detection thresholds (PPDT) compared with nonpenetrating sham acupuncture (NPSA).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

During the last decade, a multi-modal approach has been established in human experimental pain research for assessing pain thresholds and responses to various experimental pain modalities. Studies have concluded that differences in responses to pain stimuli are mainly related to variation between individuals rather than variation in response to different stimulus modalities. In a factor analysis of 272 consecutive volunteers (137 men and 135 women) who underwent tests with different experimental pain modalities, it was determined whether responses to different pain modalities represent distinct individual uncorrelated dimensions of pain perception. Volunteers underwent single painful electrical stimulation, repeated painful electrical stimulation (temporal summation), test for reflex receptive field, pressure pain stimulation, heat pain stimulation, cold pain stimulation, and a cold pressor test (ice water test). Five distinct factors were found representing responses to 5 distinct experimental pain modalities: pressure, heat, cold, electrical stimulation, and reflex-receptive fields. Each of the factors explained approximately 8% to 35% of the observed variance, and the 5 factors cumulatively explained 94% of the variance. The correlation between the 5 factors was near null (median ρ=0.00, range -0.03 to 0.05), with 95% confidence intervals for pairwise correlations between 2 factors excluding any relevant correlation. Results were almost similar for analyses stratified according to gender and age. Responses to different experimental pain modalities represent different specific dimensions and should be assessed in combination in future pharmacological and clinical studies to represent the complexity of nociception and pain experience.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Carotid sinus baroreceptors are involved in controlling blood pressure (BP) by providing input to the cardiovascular regulatory centers of the medulla. The acute effect of temporarily placing an electrode on the carotid sinus wall to electrically activate the baroreflex was investigated. We studied 11 patients undergoing elective carotid surgery. Baseline BP was 146+30/66+/-17 mm Hg and heart rate (HR) 72+/-7 bpm (mean +/- standard deviation). An electrode was placed upon the carotid sinus and after obtaining a steady state baseline of BP and HR, an electric current was applied and increased in 1-volt increments. A voltage dependent and highly significant reduction in BP was observed which averaged 18+/-26* and 8.0+/-12 mm Hg for systolic BP and diastolic BP, respectively. Maximal reductions occurred at 4.4+/-1.2 V: 23+/-24 mm Hg*, 16+/-10 mm Hg* and 7+/-12 bpm* for systolic BP, diastolic BP and HR, respectively ( = p <.05). Thus, electrical stimulation of the carotid sinus activates the carotid baroreflex resulting in a reduction in BP and HR. This presents a proof of concept for device based baroreflex modulation in acute BP regulation and adds to the available data which provide a rationale for evaluating this system in the context of chronic BP reduction in hypertensive patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effects of a single intravenous dose of butorphanol (0.1 mg kg(-1)) on the nociceptive withdrawal reflex (NWR) using threshold, suprathreshold and repeated subthreshold electrical stimuli in conscious horses. STUDY DESIGN: 'Unblinded', prospective experimental study. ANIMALS: Ten adult horses, five geldings and five mares, mean body mass 517 kg (range 487-569 kg). METHODS: The NWR was elicited using single transcutaneous electrical stimulation of the palmar digital nerve. Repeated stimulations were applied to evoke temporal summation. Surface electromyography was performed to record and quantify the responses of the common digital extensor muscle to stimulation and behavioural reactions were scored. Before butorphanol administration and at fixed time points up to 2 hours after injection, baseline threshold intensities for NWR and temporal summation were defined and single suprathreshold stimulations applied. Friedman repeated-measures analysis of variance on ranks and Wilcoxon signed-rank test were used with the Student-Newman-Keul's method applied post-hoc. The level of significance (alpha) was set at 0.05. RESULTS: Butorphanol did not modify either the thresholds for NWR and temporal summation or the reaction scores, but the difference between suprathreshold and threshold reflex amplitudes was reduced when single stimulation was applied. Upon repeated stimulation after butorphanol administration, a significant decrease in the relative amplitude was calculated for both the 30-80 and the 80-200 millisecond intervals after each stimulus, and for the whole post-stimulation interval in the right thoracic limb. In the left thoracic limb a decrease in the relative amplitude was found only in the 30-80 millisecond epoch. CONCLUSION: Butorphanol at 0.1 mg kg(-1) has no direct action on spinal Adelta nociceptive activity but may have some supraspinal effects that reduce the gain of the nociceptive system. CLINICAL RELEVANCE: Butorphanol has minimal effect on sharp immediate Adelta-mediated pain but may alter spinal processing and decrease the delayed sensations of pain.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A number of different neurorehabilitation strategies include manipulation of the somatosensory system, e.g. in the form of training by passive movement. Recently, peripheral electrical nerve stimulation has been proposed as a simple, painless method of enhancing rehabilitation of motor deficits. Several physiological studies both in animals and in humans indicate that a prolonged period of patterned peripheral electrical stimulation induces short-term plasticity at multiple levels of the motor system. Small-scale studies in humans indicate that these plastic changes are linked with improvement in motor function, particularly in patients with chronic motor deficits after stroke. Somatosensory-mediated disinhibition of motor pathways is a possible underlying mechanism and might explain why peripheral electrical stimulation is more effective when combined with active training. Further large-scale studies are needed to identify the optimal stimulation protocol and the patient groups that stand to benefit the most from this technique.