51 resultados para Electric mobility

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commonality of activation of spontaneously forming and stimulus-induced mental representations is an often made but rarely tested assumption in neuroscience. In a conjunction analysis of two earlier studies, brain electric activity during visual-concrete and abstract thoughts was studied. The conditions were: in study 1, spontaneous stimulus-independent thinking (post-hoc, visual imagery or abstract thought were identified); in study 2, reading of single nouns ranking high or low on a visual imagery scale. In both studies, subjects' tasks were similar: when prompted, they had to recall the last thought (study 1) or the last word (study 2). In both studies, subjects had no instruction to classify or to visually imagine their thoughts, and accordingly were not aware of the studies' aim. Brain electric data were analyzed into functional topographic brain images (using LORETA) of the last microstate before the prompt (study 1) and of the word-type discriminating event-related microstate after word onset (study 2). Conjunction analysis across the two studies yielded commonality of activation of core networks for abstract thought content in left anterior superior regions, and for visual-concrete thought content in right temporal-posterior inferior regions. The results suggest that two different core networks are automatedly activated when abstract or visual-concrete information, respectively, enters working memory, without a subject task or instruction about the two classes of information, and regardless of internal or external origin, and of input modality. These core machineries of working memory thus are invariant to source or modality of input when treating the two types of information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mobility of naturally occurring U-238 and U-234 radionuclides was studied in a low permeability, reducing claystone formation (Opalinus Clay) near its contact with an overlying oxidising aquifer (Dogger Limestones) at Mont Terri, Switzerland. Our data point to a limited redistribution of U in some of the studied samples. Observed centimetre-scale U mobility is explained by slow diffusive transport of U-234 in the pore waters of the Opalinus Clay driven by spatially variable in situ supply (by alpha-recoil) of U-234 from the rock matrix. Metre-scale mobility is interpreted as a result of infiltration of meteoric water into the overlying aquifer which developed gradients of U concentration across the two rock formations. This triggered a slow in-diffusion of U with (U-234/U-238) > 1 into the Opalinus Clay as attested by a clear-cut pattern of decreasing bulk rock (U-234/U-238) inwards the Opalinus Clay, away from the Dogger Limestones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gene therapy of the heart has been attempted in a number of clinical trials with the injection of naked DNA, although quantitative information on myocellular transfection rates is not available. The present study aimed to quantify the efficacy of electropulsing protocols that differ in pulse duration and number to stimulate transfection of cardiomyocytes and to determine the impact on myocardial integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The progress of wet age-related macular degeneration can now be controlled by intravitreal drug injection. This approach requires repeated injections, which could be avoided by delivering the drug to the retina. Intraocular implants are a promising solution for drug delivery near the retina. Currently, their accurate placement is challenging, and they can only be removed after a vitrectomy. In this paper, we introduce an approach for minimally invasive retinal drug delivery using magnetic intraocular inserts. We briefly discuss the electromagnetic-control system for magnetic implants and then focus on evaluating their ability to move in the vitreous humor. The mobility of magnetic intraocular implants is estimated in vitro with synthesized vitreous humors, and ex vivo with experiments on cadaver porcine eyes. Preliminary results show that with such magnetic implants a vitrectomy can be avoided.