32 resultados para Elbow tendionitis

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate topographic and age-dependent adaptation of subchondral bone density in the elbow joints of healthy dogs by means of computed tomographic osteoabsorptiometry (CTOAM). Animals-42 elbow joints of 29 clinically normal dogs of various breeds and ages. PROCEDURES: Subchondral bone densities of the humeral, radial, and ulnar joint surfaces of the elbow relative to a water-hydroxyapatite phantom were assessed by means of CTOAM. Distribution patterns in juvenile, adult, and geriatric dogs (age, < 1 year, 1 to 8 years, and > 8 years, respectively) were determined and compared within and among groups. RESULTS: An area of increased subchondral bone density was detected in the humerus distomedially and cranially on the trochlea and in the olecranon fossa. The ulna had maximum bone densities on the anconeal and medial coronoid processes. Increased bone density was detected in the craniomedial region of the joint surface of the radius. A significant age-dependent increase in subchondral bone density was revealed in elbow joint surfaces of the radius, ulna, and humerus. Mean subchondral bone density of the radius was significantly less than that of the ulna in paired comparisons for all dogs combined and in adult and geriatric, but not juvenile, dog groups. CONCLUSIONS AND CLINICAL RELEVANCE: An age-dependent increase in subchondral bone density at the elbow joint was revealed. Maximal relative subchondral bone densities were detected consistently at the medial coronoid process and central aspect of the humeral trochlea, regions that are commonly affected in dogs with elbow dysplasia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For young active dogs of large, fast-growing breeds, diseases of the elbow represent an increasing important disorder. Genetic predisposition, overweight and joint overload have been proposed as possible causes of elbow dysplasia. In this study, the influence of various biomechanical parameters on load transfer in healthy and pathological dog elbows has been analysed by means of a two-dimensional finite element model. Pathological changes in the elbow structure, such as altered material properties or asynchronous bone growth, have a distinct influence on the contact pressure in the joint articulation, internal bone deformation and stresses in the bones. The results obtained support empirical observations made during years of experience and offer explanations for clinical findings that are not yet well understood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine if the receptor activator of nuclear factor-kappaB-receptor activator of nuclear factor-kappaB ligand-osteoprotegerin (RANK-RANKL-OPG) system is active in bone remodeling in dogs and, if so, whether differences in expression of these mediators occur in healthy and arthritic joints. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Fragmented processus coronoidei (n=20) were surgically removed from dogs with elbow arthritis and 5 corresponding healthy samples from dogs euthanatized for reasons other than elbow joint disease. METHODS: Bright-field immunohistochemistry and high-resolution fluorescence microscopy were used to investigate the distribution of RANK, RANKL, and OPG in healthy and arthritic joints. RESULTS: All 3 molecules were identified by immunostaining of canine bone tissue. In elbow dysplasia, the number of RANK-positive osteoclasts was increased. In their vicinity, cells expressing RANKL, a mediator of osteoclast activation, were abundant whereas the number of osteoblasts having the potential to limit osteoclastogenesis and bone resorption via OPG was few. CONCLUSIONS: The RANK-RANKL-OPG system is active in bone remodeling in dogs. In elbow dysplasia, a surplus of molecules promoting osteoclastogenesis was evident and is indicative of an imbalance between the mediators regulating bone resorption and bone formation. Both OPG and neutralizing antibodies against RANKL have the potential to counterbalance bone resorption. CLINICAL RELEVANCE: Therapeutic use of neutralizing antibodies against RANKL to inhibit osteoclast activation warrants further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Ulnar nerve decompression at the elbow traditionally requires regional or general anesthesia. We wished to assess the feasibility of performing ulnar nerve decompression and transposition at the elbow under local anesthesia. METHODS We examined retrospectively the charts of 50 consecutive patients having undergone ulnar nerve entrapment surgery either under general or local anesthesia. Patients were asked to estimate pain on postoperative days 1 and 7 and satisfaction was assessed at 1 year. RESULTS On day 1, pain was comparable among all groups. On day 7, pain scores were twice as high when transposition was performed under general anesthesia when compared with local anesthesia. Patient satisfaction was slightly increased in the local anesthesia group. These patients were significantly more willing to repeat the surgery. CONCLUSION Ulnar nerve decompression and transposition at the elbow can be performed under local anesthesia without added morbidity when compared with general anesthesia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In patients with a rotator cuff-deficient shoulder, a combined loss of active elevation and external rotation (CLEER) can occur when both the infraspinatus and teres minor muscles are absent. A reverse shoulder arthroplasty (RSA) can restore active elevation in these patients but cannot restore active external rotation because there are no other external rotator cuff muscles. We hypothesized that a modified L'Episcopo procedure (latissimus dorsi [LD] and teres major [TM] transfer) with a simultaneous RSA would restore shoulder function and activities of daily living (ADLs).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The most widely accepted treatment for comminuted fractures of the radial head is either the excision or open reduction and internal fixation. The purpose of the present study is to evaluate the value of an 'on-table' reconstruction technique in severely comminuted fractures of the radial head. In this study, two patients with a Mason type-III and four patients with a Mason type-IV radial-head fracture were treated with 'on-table' reconstruction and fixation using low-profile mini-plates. After a mean follow-up of 112 months (47-154 months), the mean elbow motion was 0-6-141 degrees extension flexion with 79 degrees of pronation and 70 degrees of supination. The mean Broberg and Morrey functional rating score was 97.0 points, the Mayo Elbow Performance Index was 99.2 points and the mean Disabilities of the Arm, Shoulder, and Hand (DASH) Outcome Measure score was 1.94 points. One patient had symptoms of degenerative changes, with a slight joint-space narrowing. There were no radiographic signs of devitalisation at final examination. Comminuted fractures of the radial head, which would otherwise require excision, can be successfully treated with an 'on-table' reconstruction technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 55-year-old woman was referred because of diffuse pruritic erythematous lesions and an ischemic process of the third finger of her right hand. She was known to have anaemia secondary to hypermenorrhea. She presented six months before admission with a cutaneous infiltration on the left cubital cavity after a paravenous leakage of intravenous iron substitution. She then reported a progressive pruritic erythematous swelling of her left arm and lower extremities and trunk. Skin biopsy of a lesion on the right leg revealed a fibrillar, small-vessel vasculitis containing many eosinophils.Two months later she reported Raynaud symptoms in both hands, with a persistent violaceous coloration of the skin and cold sensation of her third digit of the right hand. A round 1.5 cm well-delimited swelling on the medial site of the left elbow was noted. The third digit of her right hand was cold and of violet colour. Eosinophilia (19 % of total leucocytes) was present. Doppler-duplex arterial examination of the upper extremities showed an occlusion of the cubital artery down to the palmar arcade on the right arm. Selective angiography of the right subclavian and brachial arteries showed diffuse alteration of the blood flow in the cubital artery and hand, with fine collateral circulation in the carpal region. Neither secondary causes of hypereosinophilia nor a myeloproliferative process was found. Considering the skin biopsy results and having excluded other causes of eosinophilia, we assumed the diagnosis of an eosinophilic vasculitis. Treatment with tacrolimus and high dose steroids was started, the latter tapered within 12 months and then stopped, but a dramatic flare-up of the vasculitis with Raynaud phenomenon occurred. A new immunosuppressive approach with steroids and methotrexate was then introduced. This case of aggressive eosinophilic vasculitis is difficult to classify into the usual forms of vasculitis and constitutes a therapeutic challenge given the resistance to current immunosuppressive regimens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the technical feasibility of harvesting a vascularized bone graft from the acromion pedicled on the acromial branch.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The etiology of shoulder pain in the overhead athlete is often difficult to determine. This study hypothesized that (1) instability can present in a purely painful form, without any apparent history of instability, but with anatomic lesions indicative of instability, termed unstable painful shoulder (UPS), and that (2) arthroscopic shoulder stabilization is effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background: Aerosol therapy in preterm infants is challenging, as a very small proportion of the drug deposits in the lungs. Aim: Our aim was to compare efficiency of standard devices with newer, more efficient aerosol delivery devices. Methods: Using salbutamol as a drug marker, we studied two prototypes of the investigational eFlow(®) nebulizer for babies (PARI Pharma GmbH), a jet nebulizer (Intersurgical(®) Cirrus(®)), and a pressurized metered dose inhaler (pMDI; GSK) with a detergent-coated holding chamber (AeroChamber(®) MV) in the premature infant nose throat-model (PrINT-model) of a 32-week preterm infant (1,750 g). A filter or an impactor was placed below the infant model's "trachea" to capture the drug dose or particle size, respectively, that would have been deposited in the lung. Results: Lung dose (percentage of nominal dose) was 1.5%, 6.8%, and 18.0-20.6% for the jet nebulizer, pMDI-holding chamber, and investigational eFlow nebulizers, respectively (p<0.001). Jet nebulizer residue was 69.4% and 10.7-13.9% for the investigational eFlow nebulizers (p<0.001). Adding an elbow extension between the eFlow and the model significantly lowered lung dose (p<0.001). A breathing pattern with lower tidal volume decreased deposition in the PrINT-model and device residue (p<0.05), but did not decrease lung dose. Conclusions: In a model for infant aerosol inhalation, we confirmed low lung dose using jet nebulizers and pMDI-holding chambers, whereas newer, more specialized vibrating membrane devices, designed specifically for use in preterm infants, deliver up to 20 times more drug to the infant's lung.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although loosening of cemented glenoid components is one of the major complications of total shoulder arthroplasty, there is little information about factors affecting initial fixation of these components in the scapular neck. This study was performed to assess the characteristics of structural fixation of pegged glenoid components, if inserted with two different recommended cementing techniques. Six fresh-frozen shoulder specimens and two types of glenoid components were used. The glenoids were prepared according to the instructions and with the instrumentation of the manufacturer. In 3 specimens, the bone cement was inserted into the peg receiving holes (n = 12) and applied to the back surface of the glenoid component with a syringe. In the other 3 specimens, the cement was inserted into the holes (n = 15) by use of pure finger pressure: no cement was applied on the backside of the component. Micro-computed tomography scans with a resolution of 36 microm showed an intact cement mantle around all 12 pegs (100%) when a syringe was used. An incomplete cement plug was found in 7 of 15 pegs (47%) when the finger-pressure technique was used. Cement penetration into the cancellous bone was deeper in osteopenic bone. Application of bone cement on the backside of the glenoid prosthesis improved seating by filling out small spaces between bone and polyethylene resulting from irregularities after reaming or local cement extrusion from a drill hole. The fixation of a pegged glenoid component is better if the holes are filled with cement under pressure by use of a syringe and if cement is applied to the back of the glenoid component than if cement is inserted with pure finger pressure and no cement is applied to the back surface of the component.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to determine whether changes in glenoid version are associated with humeral head displacement and changes in the joint reaction forces, as these might contribute to instability or loosening in total shoulder replacement. A total shoulder prosthesis was implanted in neutral version in 6 cadaveric shoulders. Glenoid version was then changed in steps of 4 degrees toward more anteversion and retroversion. An increase in anteversion resulted in anterior translation of the humeral head and in eccentric loading of the anterior part of the glenoid. Retroversion was associated with posterior displacement and posterior loading of the glenoid. A change in rotation of the humeral component did not compensate for altered version of the glenoid component. These results suggest that both instability and glenoid component loosening may be related to the version of the glenoid component. Therefore, assessment of loosening and instability justifies precise assessment of glenoid component version.