11 resultados para ETHYL CARBAMATE

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In abstinence maintenance programs, for reissuing the driving licence and in workplace monitoring programs abstinence from ethanol and its proof are demanded. Various monitoring programs that mainly use ethyl glucuronide (EtG) as alcohol consumption marker have been established. To abstain from ethanol, but not from the taste of alcoholic beverages, in particular non-alcoholic beer has become more and more popular. In Germany, these "alcohol-free" beverages may still have an ethanol content of up to 0.5vol.% without the duty of declaration. Due to severe negative consequences resulting from positive EtG tests, a drinking experiment with 2.5L of non-alcoholic beer per person was performed to address the question of measurable concentrations of the direct metabolites EtG and EtS (ethyl sulphate) in urine and blood. Both alcohol consumption markers - determined by LC-MS/MS - were found in high concentrations: maximum concentrations in urine found in three volunteers were EtG 0.30-0.87mg/L and EtS 0.04-0.07mg/L, i.e., above the often applied cut-off value for the proof of abstinence of 0.1mg EtG/L. In the urine samples of one further volunteer, EtG and EtS concentrations cumulated over-night and reached up to 14.1mg/L EtG and 16.1mg/L EtS in the next morning's urine. Ethanol concentrations in blood and urine samples were negative (determined by HS-GC-FID and by an ADH-based method).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to show that sensitive detection of ethyl glucuronide in dried blood spotted onto various surfaces after a period of 24h is feasible. At present, there is insufficient information how tightly ethyl glucuronide (EtG) binds to various materials and how easily it can be eluted. 4ml aliquots of blood samples obtained from seven volunteers after consumption of alcoholic beverages were applied to six different surfaces. After drying and a 24h-storage at 20±2°C the samples were re-dissolved in water, and EtG was subsequently analyzed by a LC-MS Paul-type ion trap. A comparison was made between dried and corresponding fluid samples. EtG was detectable in all subjects' samples following consumption of alcohol. EtG was also detectable after a storage time of four weeks at 4°C in whole blood that had been preserved with EDTA. EtG was detectable in all samples dried on different surfaces and its concentration remained relatively constant irrespective of the particular condition of the material. Detection of EtG in blood spots from the scene may indicate recent alcohol consumption in cases where collection of blood remained undone or could not be performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To clarify the circumstances of death, the degree of inebriation is of importance in many cases, but for several reasons the determination of the ethanol concentration in post-mortem samples can be challenging and the synopsis of ethanol and the direct consumption markers ethyl glucuronide (EtG) and ethyl sulphate (EtS) has proved to be useful. The use of a rather stable matrix like vitreous humor offers further advantages. The aim of this study was to determine the concentrations of ethanol and the biomarkers in the robust matrix of vitreous humor and to compare them with the respective levels in peripheral venous blood and urine. Samples of urine, blood from the femoral vein and vitreous humor were taken from 26 deceased with suspected ethanol consumption prior to death and analyzed for ethanol, EtS and EtG. In the urine samples creatinine was also determined. The personal data, the circumstances of death, the post-mortem interval and the information about ethanol consumption prior to death were recorded. EtG and EtS analysis in urine was performed by LC-ESI-MS/MS, creatinine concentration was determined using the Jaffé reaction and ethanol was detected by HS-GC-FID and by an ADH-based method. In general, the highest concentrations of the analytes were found in urine and showed statistical significance. The mean concentrations of EtG were 62.8mg/L (EtG100 206.5mg/L) in urine, 4.3mg/L in blood and 2.1mg/L in vitreous humor. EtS was found in the following mean concentrations: 54.6mg/L in urine (EtS100 123.1mg/L), 1.8mg/L in blood and 0.9mg/L in vitreous humor. Ethanol was detected in more vitreous humor samples (mean concentration 2.0g/kg) than in blood and urine (mean concentration 1.6g/kg and 2.1g/kg respectively). There was no correlation between the ethanol and the marker concentrations and no statistical conclusions could be drawn between the markers and matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CZE coupled to sheath liquid-based electrospray ionization (ESI) and multiple-stage ion trap mass spectrometry (MS(n) ) was used for the confirmation analysis of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in human serum and urine collected after intake of alcoholic beverages. Electrophoretic separations were performed in uncoated fused-silica capillaries using a pH 9.5 ammonium acetate background electrolyte and normal polarity. MS detection of EtG and EtS occurred after negative ionization using a spray liquid containing 0.5% v/v ammonia in isopropanol/water (60:40%, v/v). CZE-MS and CZE-MS² results obtained after injection of solid-phase extracts for EtG and EtS and of diluted urine confirmed the presence of EtG and EtS in samples whose levels were previously determined by CZE with indirect UV detection. Detection limits of each compound were estimated to be around 2.0 (injection of diluted urine) and 0.2 μg/mL (extracts).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of ethyl glucuronide (EtG), a marker of recent alcohol consumption, in serum with an optimized CZE assay is reported. The method uses a 0.1-mm id fused-silica capillary of 50 cm effective length that is coated with linear polyacrylamide, a pH 4.4 nicotinic acid/epsilon-aminocaproic acid (EACA) BGE, reversed polarity and indirect analyte detection. The assay is based on a 1:1 dilution of serum with deionized water and has LODs for EtG, lactate and acetate of 3.8 x 10(-7) M, 2.60 x 10(-6 )M and 2.18 x 10(-6 )M, respectively. Separation of EtG from endogenous macro- and microcomponents (anionic serum components of high and low concentration, respectively) and its quantification are shown to be possible for a wide range of lactate (stacker) and acetate (destacker) concentrations, macrocomponents that have an impact on the CZE behavior of EtG and that change after intake of ethanol. The assay has been successfully applied to the analysis of EtG, lactate and acetate in (i) sera of volunteers that ingested known amounts of alcohol and (ii) samples of patients that were classified (teetotalers and social drinkers vs. alcohol abusers) via analysis of carbohydrate-deficient transferrin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of capillary zone electrophoresis (CZE) with indirect absorbance detection for the analysis of ethyl sulfate (EtS) in serum and urine was investigated. EtS is a direct metabolite of ethanol employed as marker for recent alcohol consumption. Fused-silica capillaries of 60 cm total length were either coated with cetyltrimethylammonium bromide (CTAB, 50 microm I.D. capillary) or poly(diallyldimethylammonium chloride) (PDADMAC, 100 microm I.D. capillary) to allow CZE analyses to be performed with reversed polarity. At pH 2.2 with a maleic acid/phthalic acid background electrolyte, both approaches provided reliable EtS serum levels down to 0.2 mg L(-1) (1.6 microM) for the analysis of solid-phase extracts that were prepared after chloride precipitation. Analysis of urines diluted to a conductivity of 5 S m(-1) and analyzed in the two capillary formats resulted in limits of quantification (LOQs) of 2 and 1 mg L(-1), respectively. With urines adjusted to 10 S m(-1) via dilution or condensation, an LOQ of 0.6 mg L(-1) (4.8 microM) was obtained in the CTAB coated capillary whereas in the PDADMAC-coated capillary of equal length not all matrix components were resolved from EtS. The developed assays are robust and suitable to monitor EtS in samples of individuals who consumed as little as one standard drink of an alcoholic beverage containing about 14 g of ethanol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) is a marker of recent alcohol consumption. For the optimization of the analysis of EtG by CZE with indirect absorbance detection, the use of capillaries with permanent and dynamic wall coatings, the composition of the BGE, and various sample preparation procedures, including dilution with water, ultrafiltration, protein precipitation, and SPE, were investigated. Two validated screening assays for the determination of EtG in human serum, a CZE-based approach and an enzyme immunoassay (EIA), are described. The CZE assay uses a coated capillary, 2,4-dimethylglutaric acid as an internal standard, and a pH 4.65 BGE comprising 9 mM nicotinic acid, epsilon-aminocaproic acid and 10% v/v ACN. Proteins are removed via precipitation with ACN prior to analysis and the LOQ is 0.50 mg/L. The EIA is based upon commercial reagents which are promoted for the determination of urinary EtG. Krebs-Ringer solution containing 5% BSA is used as a calibration matrix. All samples are ultrafiltered prior to analysis of the ultrafiltrate on a Mira Plus analyzer. Assay calibration ranged between 0 and 2 mg/L and the upper reference limit was determined to be 0.05 mg/L. Both assays proved to be suitable for the analysis of samples from different individuals. For EtG levels above 0.50 mg/L, good agreement was observed for the comparison of the results of the two methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are non-oxidative minor metabolites of ethanol. They are detectable in various body fluids shortly after initial consumption of ethanol and have a longer detection time frame than the parent compound. They are regarded highly sensitive and specific markers of recent alcohol uptake. This study evaluates the determination of EtG and EtS from dried blood spots (DBS), a simple and cost-effective sampling method that would shorten the time gap between offense and blood sampling and lead to a better reflectance of the actual impairment. METHODS: For method validation, EtG and EtS standard and quality control samples were prepared in fresh human heparinized blood and spotted on DBS cards, then extracted and measured by an LC-ESI-MS/MS method. Additionally, 76 heparinized blood samples from traffic offense cases were analyzed for EtG and EtS as whole blood and as DBS specimens. The results from these measurements were then compared by calculating the respective mean values, by a matched-paired t test, by a Wilcoxon test, and by Bland-Altman and Mountain plots. RESULTS AND DISCUSSION: Calibrations for EtG and EtS in DBS were linear over the studied calibration range. The precision and accuracy of the method met the requirements of the validation guidelines that were employed in the study. The stability of the biomarkers stored as DBS was demonstrated under different storage conditions. The t test showed no significant difference between whole blood and DBS in the determination of EtG and EtS. In addition, the Bland-Altman analysis and Mountain plot confirmed that the concentration differences that were measured in DBS specimens were not relevant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A drinking experiment with participants suffering from Gilbert's syndrome was performed to study the possible influence of this glucuronidation disorder on the formation of ethyl glucuronide (EtG). Gilbert's syndrome is a rather common and, in most cases, asymptomatic congenital metabolic aberration with a prevalence of about 5 %. It is characterized by a reduction of the enzyme activity of the uridine diphosphate glucuronosyltransferase (UGT) isoform 1A1 up to 80 %. One of the glucuronidation products is EtG, which is formed in the organism following exposure to ethanol. EtG is used as a short-term marker for ethyl alcohol consumption to prove abstinence in various settings. After 2 days of abstinence from ethanol and giving a void urine sample, 30 study participants drank 0.1 L of sparkling wine (9 g ethanol). 3, 6, 12, and 24 h after drinking, urine samples were collected. 3 hours after drinking, an additional blood sample was taken, in which liver enzyme activities, ethanol, hematological parameters, and bilirubin were measured. EtG and ethyl sulfate (EtS), another short-term marker of ethanol consumption, were determined in the urine samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS); creatinine was measured photometrically. In all participants, EtG and EtS were detected in concentrations showing a wide range (EtG: 3 h sample 0.5-18.43 mg/L and 6 h sample 0.67-13.8 mg/L; EtS: 3 h sample 0.87-6.87 mg/L and 6 h sample 0.29-4.48 mg/L). No evidence of impaired EtG formation was found. Thus, EtG seems to be a suitable marker for ethanol consumption even in individuals with Gilbert's syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The forensic utility of fatty acid ethyl esters (FAEEs) in dried blood spots (DBS) as short-term confirmatory markers for ethanol intake was examined. An LC-MS/MS method for the determination of FAEEs in DBS was developed and validated to investigate FAEE formation and elimination in a drinking study, whereby eight subjects ingested 0.66-0.84 g/kg alcohol to reach blood alcohol concentrations (BAC) of 0.8 g/kg. Blood was taken every 1.5-2 h, BAC was determined, and dried blood spots were prepared, with 50 μL of blood, for the determination of FAEEs. Lower limits of quantitation (LLOQ) were between 15 and 37 ng/mL for the four major FAEEs. Validation data are presented in detail. In the drinking study, ethyl palmitate and ethyl oleate proved to be the two most suitable markers for FAEE determination. Maximum FAEE concentrations were reached in samples taken 2 or 4 h after the start of drinking. The following mean peak concentrations (c̅ max) were reached: ethyl myristate 14 ± 4 ng/mL, ethyl palmitate 144 ± 35 ng/mL, ethyl oleate 125 ± 55 ng/mL, ethyl stearate 71 ± 21 ng/mL, total FAEEs 344 ± 91 ng/mL. Detectability of FAEEs was found to be on the same time scale as BAC. In liquid blood samples containing ethanol, FAEE concentrations increase post-sampling. This study shows that the use of DBS fixation prevents additional FAEE formation in blood samples containing ethanol. Positive FAEE results obtained by DBS analysis can be used as evidence for the presence of ethanol in the original blood sample. Graphical Abstract Time courses for fatty acid ethyl ester (FAEE) concentrations in DBS and ethanol concentrations for subject 1 over a period of 7 h. Ethanol ingestion occured during the first hour of the time course.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For driving aptitude assessment (DAA), the analysis of several alcohol biomarkers is essential for the detection of alcohol intake besides psycho-medical exploration. In Switzerland, EtG in hair (hEtG) is often the only direct marker for abstinence monitoring in DAA. Therefore, the suitability of phosphatidylethanol (PEth) was investigated as additional biomarker. PEth 16:0/18:1 and 16:0/18:2 were determined by online-SPE-LC-MS/MS in 136 blood samples of persons undergoing DAA and compared to hEtG, determined in hair segments taken at the same time. With a PEth 16:0/18:1 threshold of 210 ng/mL for excessive alcohol consumption, all (n = 30) but one tested person also had hEtG values ≥30 pg/mg. In 54 cases, results are not in contradiction to an abstinence as neither PEth (<20 ng/mL) nor hEtG (<7 pg/mg) was detected. In eight cases, both markers showed moderate consumption. Altogether, PEth and hEtG were in accordance in 68 % of the samples, although covering different time periods of alcohol consumption. With receiver operating characteristic analysis, PEth was evaluated to differentiate abstinence, moderate, and excessive alcohol consumption in accordance with hEtG limits. A PEth 16:0/18:1 threshold of 150 ng/mL resulted in the best sensitivity (70.6 %) and specificity (98.8 %) for excessive consumption. Values between 20 and 150 ng/mL passed for moderate consumption, values <20 ng/mL passed for abstinence. As PEth mostly has a shorter detection window (2-4 weeks) than hEtG (up to 6 months depending on hair length), changes in drinking behavior can be detected earlier by PEth than by hEtG analysis alone. Therefore, PEth helps to improve the diagnostic information and is a valuable additional alcohol marker for DAA.