17 resultados para EASE.

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two major difficulties arise when taking blood samples in children: the challenge of venous access and the comparatively large amount of blood required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this article is to demonstrate the feasibility of on-demand creation of cloud-based elastic mobile core networks, along with their lifecycle management. For this purpose the article describes the key elements to realize the architectural vision of EPC as a Service, an implementation option of the Evolved Packet Core, as specified by 3GPP, which can be deployed in cloud environments. To meet several challenging requirements associated with the implementation of EPC over a cloud infrastructure and providing it “as a Service,” this article presents a number of different options, each with different characteristics, advantages, and disadvantages. A thorough analysis comparing the different implementation options is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study investigated how ease of imagery influences source monitoring accuracy. Two experiments were conducted in order to examine how ease of imagery influences the probability of source confusions of perceived and imagined completions of natural symmetric shapes. The stimuli consisted of binary pictures of natural objects, namely symmetric pictures of birds, butterflies, insects, and leaves. The ease of imagery (indicating the similarity of the sources) and the discriminability (indicating the similarity of the items) of each stimulus were estimated in a pretest and included as predictors of the memory performance for these stimuli. It was found that confusion of the sources becomes more likely when the imagery process was relatively easy. However, if the different processes of source monitoring-item memory, source memory and guessing biases-are disentangled, both experiments support the assumption that the effect of decreased source memory for easily imagined stimuli is due to decision processes and misinformation at retrieval rather than encoding processes and memory retention. The data were modeled with a Bayesian hierarchical implementation of the one high threshold source monitoring model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prosthesis-patient mismatch (PPM) remains a controversial issue with the most recent stented biological valves. We analyzed the incidence of PPM after implantation of the Carpentier-Edwards Perimount Magna Ease aortic valve (PMEAV) bioprosthesis and assessed the early clinical outcome. Two hundred and seventy consecutive patients who received a PMEAV bioprosthesis between January 2007 and July 2008 were analyzed. Pre-, peri- and postoperative data were assessed and echocardiographic as well as clinical follow-up was performed. Mean age was 72+/-9 years, 168 (62.2%) were males. Fifty-seven patients (21.1%) were below 65 years of age. Absence of PPM, corresponding to an indexed effective orifice area >0.85 cm(2)/m(2), was 99.5%. Observed in-hospital mortality was 2.2% (six patients), with a predicted mortality according to the additive EuroSCORE of 7.6+/-3.1%. At echocardiographic assessment after a mean follow-up period of 150+/-91 days, mean transvalvular gradient was 11.8+/-4.8 mmHg (all valve sizes). No paravalvular leakage was seen. Nine patients died during follow-up. The Carpentier-Edwards PMEAV bioprosthesis shows excellent hemodynamic performance. This valve can be implanted in all sizes with an incidence of severe PPM below 0.5%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because the recommendation to use flowables for posterior restorations is still a matter of debate, the objective of this study was to determine in a nationwide survey in Germany how frequently, for what indications, and for what reasons, German dentists use flowable composites in posterior teeth. In addition, the acceptance of a simplified filling technique for posterior restorations using a low stress flowable composite was evaluated. Completed questionnaires from all over Germany were returned by 1,449 dentists resulting in a response rate of 48.5%; 78.6% of whom regularly used flowable composites for posterior restorations. The most frequent indications were cavity lining (80.1%) and small Class I fillings (74.2%). Flowables were less frequently used for small Class II fillings (22.7%) or other indications (13.6%). Most frequent reasons given for the use of flowables in posterior teeth were the prevention of voids (71.7%) and superior adaptation to cavity walls (72.9%), whereas saving time was considered less important (13.8%). Based on the subjective opinion of the dentists the simplified filling technique seemed to deliver advantages compared to the methods used to date particularly with regard to good cavity adaptation and ease of use. In conclusion, resin composites are the standard material type used for posterior restorations by general dental practitioners in Germany and most dentists use flowable composites as liners.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The promise of search-driven development is that developers will save time and resources by reusing external code in their local projects. To efficiently integrate this code, users must be able to trust it, thus trustability of code search results is just as important as their relevance. In this paper, we introduce a trustability metric to help users assess the quality of code search results and therefore ease the cost-benefit analysis they undertake trying to find suitable integration candidates. The proposed trustability metric incorporates both user votes and cross-project activity of developers to calculate a "karma" value for each developer. Through the karma value of all its developers a project is ranked on a trustability scale. We present JBENDER, a proof-of-concept code search engine which implements our trustability metric and we discuss preliminary results from an evaluation of the prototype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Keyboards, mice, and touch screens are a potential source of infection or contamination in operating rooms, intensive care units, and autopsy suites. The authors present a low-cost prototype of a system, which allows for touch-free control of a medical image viewer. This touch-free navigation system consists of a computer system (IMac, OS X 10.6 Apple, USA) with a medical image viewer (OsiriX, OsiriX foundation, Switzerland) and a depth camera (Kinect, Microsoft, USA). They implemented software that translates the data delivered by the camera and a voice recognition software into keyboard and mouse commands, which are then passed to OsiriX. In this feasibility study, the authors introduced 10 medical professionals to the system and asked them to re-create 12 images from a CT data set. They evaluated response times and usability of the system compared with standard mouse/keyboard control. Users felt comfortable with the system after approximately 10 minutes. Response time was 120 ms. Users required 1.4 times more time to re-create an image with gesture control. Users with OsiriX experience were significantly faster using the mouse/keyboard and faster than users without prior experience. They rated the system 3.4 out of 5 for ease of use in comparison to the mouse/keyboard. The touch-free, gesture-controlled system performs favorably and removes a potential vector for infection, protecting both patients and staff. Because the camera can be quickly and easily integrated into existing systems, requires no calibration, and is low cost, the barriers to using this technology are low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our society uses a large diversity of co-existing wired and wireless networks in order to satisfy its communication needs. A cooper- ation between these networks can benefit performance, service availabil- ity and deployment ease, and leads to the emergence of hybrid networks. This position paper focuses on a hybrid mobile-sensor network identify- ing potential advantages and challenges of its use and defining feasible applications. The main value of the paper, however, is in the proposed analysis approach to evaluate the performance at the mobile network side given the mixed mobile-sensor traffic. The approach combines packet- level analysis with modelling of flow-level behaviour and can be applied for the study of various application scenarios. In this paper we consider two applications with distinct traffic models namely multimedia traffic and best-effort traffic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zeki and co-workers recently proposed that perception can best be described as locally distributed, asynchronous processes that each create a kind of microconsciousness, which condense into an experienced percept. The present article is aimed at extending this theory to metacognitive feelings. We present evidence that perceptual fluency-the subjective feeling of ease during perceptual processing-is based on speed of processing at different stages of the perceptual process. Specifically, detection of briefly presented stimuli was influenced by figure-ground contrast, but not by symmetry (Experiment 1) or the font (Experiment 2) of the stimuli. Conversely, discrimination of these stimuli was influenced by whether they were symmetric (Experiment 1) and by the font they were presented in (Experiment 2), but not by figure-ground contrast. Both tasks however were related with the subjective experience of fluency (Experiments 1 and 2). We conclude that subjective fluency is the conscious phenomenal correlate of different processing stages in visual perception.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Translocation of nanoparticles (NP) from the pulmonary airways into other pulmonary compartments or the systemic circulation is controversially discussed in the literature. In a previous study it was shown that titanium dioxide (TiO2) NP were "distributed in four lung compartments (air-filled spaces, epithelium/endothelium, connective tissue, capillary lumen) in correlation with compartment size". It was concluded that particles can move freely between these tissue compartments. To analyze whether the distribution of TiO2 NP in the lungs is really random or shows a preferential targeting we applied a newly developed method for comparing NP distributions. METHODS: Rat lungs exposed to an aerosol containing TiO2 NP were prepared for light and electron microscopy at 1 h and at 24 h after exposure. Numbers of TiO2 NP associated with each compartment were counted using energy filtering transmission electron microscopy. Compartment size was estimated by unbiased stereology from systematically sampled light micrographs. Numbers of particles were related to compartment size using a relative deposition index and chi-squared analysis. RESULTS: Nanoparticle distribution within the four compartments was not random at 1 h or at 24 h after exposure. At 1 h the connective tissue was the preferential target of the particles. At 24 h the NP were preferentially located in the capillary lumen. CONCLUSION: We conclude that TiO2 NP do not move freely between pulmonary tissue compartments, although they can pass from one compartment to another with relative ease. The residence time of NP in each tissue compartment of the respiratory system depends on the compartment and the time after exposure. It is suggested that a small fraction of TiO2 NP are rapidly transported from the airway lumen to the connective tissue and subsequently released into the systemic circulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The molecular engineering of cell-instructive artificial extracellular matrices is a powerful means to control cell behavior and enable complex processes of tissue formation and regeneration. This work reports on a novel method to produce such smart biomaterials by recapitulating the crosslinking chemistry and the biomolecular characteristics of the biopolymer fibrin in a synthetic analog. We use activated coagulation transglutaminase factor XIIIa for site-specific coupling of cell adhesion ligands and engineered growth factor proteins to multiarm poly(ethylene glycol) macromers that simultaneously form proteolytically sensitive hydrogel networks in the same enzyme-catalyzed reaction. Growth factor proteins are quantitatively incorporated and released upon cell-derived proteolytic degradation of the gels. Primary stromal cells can invade and proteolytically remodel these networks both in an in vitro and in vivo setting. The synthetic ease and potential to engineer their physicochemical and bioactive characteristics makes these hybrid networks true alternatives for fibrin as provisional drug delivery platforms in tissue engineering.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A major barrier to widespread clinical implementation of Monte Carlo dose calculation is the difficulty in characterizing the radiation source within a generalized source model. This work aims to develop a generalized three-component source model (target, primary collimator, flattening filter) for 6- and 18-MV photon beams that match full phase-space data (PSD). Subsource by subsource comparison of dose distributions, using either source PSD or the source model as input, allows accurate source characterization and has the potential to ease the commissioning procedure, since it is possible to obtain information about which subsource needs to be tuned. This source model is unique in that, compared to previous source models, it retains additional correlations among PS variables, which improves accuracy at nonstandard source-to-surface distances (SSDs). In our study, three-dimensional (3D) dose calculations were performed for SSDs ranging from 50 to 200 cm and for field sizes from 1 x 1 to 30 x 30 cm2 as well as a 10 x 10 cm2 field 5 cm off axis in each direction. The 3D dose distributions, using either full PSD or the source model as input, were compared in terms of dose-difference and distance-to-agreement. With this model, over 99% of the voxels agreed within +/-1% or 1 mm for the target, within 2% or 2 mm for the primary collimator, and within +/-2.5% or 2 mm for the flattening filter in all cases studied. For the dose distributions, 99% of the dose voxels agreed within 1% or 1 mm when the combined source model-including a charged particle source and the full PSD as input-was used. The accurate and general characterization of each photon source and knowledge of the subsource dose distributions should facilitate source model commissioning procedures by allowing scaling the histogram distributions representing the subsources to be tuned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECT: Fat suppressed 3D steady-state free precession (SSFP) sequences are of special interest in cartilage imaging due to their short repetition time in combination with high signal-to-noise ratio. At low-to-high fields (1.5-3.0 T), spectral spatial (spsp) radio frequency (RF) pulses perform superiorly over conventional saturation of the fat signal (FATSAT pulses). However, ultra-high fields (7.0 T and more) may offer alternative fat suppression techniques as a result of the increased chemical shift. MATERIALS AND METHODS: Application of a single, frequency selective, RF pulse is compared to spsp excitation for water (or fat) selective imaging at 7.0 T. RESULTS: For SSFP, application of a single frequency selective RF pulse for selective water or fat excitation performs beneficially over the commonly applied spsp RF pulses. In addition to the overall improved fat suppression, the application of single RF pulses leads to decreased power depositions, still representing one of the major restrictions in the design and application of many pulse sequences at ultra-high fields. CONCLUSION: The ease of applicability and implementation of single frequency selective RF pulses at ultra-high-fields might be of great benefit for a vast number of applications where fat suppression is desirable or fat-water separation is needed for quantification purposes.