22 resultados para Durability.

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Little is known about time trends, predictors, and consequences of changes made to antiretroviral therapy (ART) regimens early after patients initially start treatment. METHODS: We compared the incidence of, reasons for, and predictors of treatment change within 1 year after starting combination ART (cART), as well as virological and immunological outcomes at 1 year, among 1866 patients from the Swiss HIV Cohort Study who initiated cART during 2000--2001, 2002--2003, or 2004--2005. RESULTS: The durability of initial regimens did not improve over time (P = .15): 48.8% of 625 patients during 2000--2001, 43.8% of 607 during 2002--2003, and 44.3% of 634 during 2004--2005 changed cART within 1 year; reasons for change included intolerance (51.1% of all patients), patient wish (15.4%), physician decision (14.8%), and virological failure (7.1%). An increased probability of treatment change was associated with larger CD4+ cell counts, larger human immunodeficiency virus type 1 (HIV-1) RNA loads, and receipt of regimens that contained stavudine or indinavir/ritonavir, but a decreased probability was associated with receipt of regimens that contained tenofovir. Treatment discontinuation was associated with larger CD4+ cell counts, current use of injection drugs, and receipt of regimens that contained nevirapine. One-year outcomes improved between 2000--2001 and 2004--2005: 84.5% and 92.7% of patients, respectively, reached HIV-1 RNA loads of <50 copies/mL and achieved median increases in CD4+ cell counts of 157.5 and 197.5 cells/microL, respectively (P < .001 for all comparisons). CONCLUSIONS: Virological and immunological outcomes of initial treatments improved between 2000--2001 and 2004--2005, irrespective of uniformly high rates of early changes in treatment across the 3 study intervals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objectives We report our institutional experience and long-term results with the Sorin Freedom SOLO bovine pericardial stentless bioprosthesis. Methods Between January 2005 and November 2009, 149 patients (mean age 73.6±8.7 years, 68 [45.6%] female) underwent isolated (n=75) or combined (n=74) aortic valve replacement (AVR) using the SOLO in our institution. Follow-up was 100% complete with an average follow-up time of 5.9±2.6 years (maximum 9.6 years) and a total of 885.3 patient years. Results Operative (30-day) mortality was 2.7% (1.3% for isolated AVR [n=1] and 4.0% for combined procedures [n=3]). All causes of death were not valve-related. Preoperative peak (mean) gradients of 74.2±23.0 mmHg (48.6 ± 16.3 mmHg) decreased to 15.6±5.4 (8.8±3.0) after AVR, and remained low for up to 9 years. The postoperative effective orifice area (EOA) was 1.6 ±0.57 cm2, 1.90±0.45 cm2, 2.12±0.48 cm2 and 2.20±0.66 cm2 for the valve sizes 21, 23, 25 and 27, respectively; with absence of severe prosthesis-patient-mismatch (PPM) and 0.7% (n=1) moderate PPM. During follow-up, Twenty-six patients experienced structural valve deterioration (SVD) and 14 patients underwent explantation. Kaplan-Meier estimates for freedom from death, explantation and SVD at 9 years averaged 0.57 [0.47‒0.66], 0.82 [0.69‒0.90] and 0.70 [0.57‒0.79], respectively. Conclusions The Freedom SOLO stentless aortic valve is safe to implant and shows excellent early and mid-term hemodynamic performance. However, SVD was observed in a substantial number of patients after only 5 ̶ 6 years and the need for explantation increased markedly, suggesting low durability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For preventing erosive wear in dentine, coating with adhesives has been suggested as an alternative to fluoridation. However, clinical studies have revealed limited efficacy. As there is first evidence that Sn(2+) increases bond strength of the adhesive Clearfil SE (Kuraray), the aim of the present study was to investigate whether pre-treatment with different Sn(2+)/F(-) solutions improves the durability of Clearfil SE coatings. Dentine samples (eight groups, n=16/group) were freed of smear layer (0.5% citric acid, 10 s), treated (15 s) either with no solution (control), aminefluoride (AmF, 500 ppm F(-), pH 4.5), SnCl2 (800/1600 ppm Sn(2+); pH 1.5), SnCl2/AmF (500 ppm F(-), 800 ppm Sn(2+), pH 1.5/3.0/4.5), or Elmex Erosion Protection Rinse (EP, 500 ppm F-, 800 ppm Sn(2+), pH 4.5; GABA International), then rinsed with water (15 s) and individually covered with Clearfil SE. Subsequently the specimens were subjected to an erosion/abrasion protocol consisting of 1320 cycles of immersion in 0.5% citric acid (5 °C/55 °C; 2 min) and automated brushing (15 s, 200 g, NaF-toothpaste, RDA 80). As the coatings proved stable up to 1320 cycles, 60 modified cycles (brushing time 30 min/cycle) were added. Wear was measured profilometrically. After SnCl2/AmF, pH 4.5 or EP pre-treatment all except one coating survived. In the other groups, almost all coatings were lost and there was no significant difference to the control group. Pre-treatment with a Sn(2+)/F(-) solution at pH 4.5 seems able to improve the durability of adhesive coatings, rendering these an attractive option in preventing erosive wear in dentine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the use of covered stent-grafts in the endovascular treatment (ET) of popliteal artery aneurysms (PAAs). MATERIALS AND METHODS: A retrospective analysis was conducted over a period of 52 months in 18 consecutive patients (17 men; mean age +/- SD, 70 years +/- 11) undergoing ET of PAAs with the Viabahn endograft in a single center. Patient symptoms, aneurysm characteristics, technical outcomes, complications, and follow-up were assessed. RESULTS: Aneurysm diameters ranged from 12 to 51 mm with a mean of 30 mm (+/-11). Thirteen aneurysms (72.2%) were partially thrombosed and 12 patients (66.6%) had symptoms of lower limb ischemia at presentation (11 chronic and one acute). The technical success rate was 94%. Intraprocedural emboli and endoleak occurred in one and two patients, respectively. Fourteen patients were available for follow-up after successful treatment, with a mean follow-up time of 15 months (range, 7-37 months). All stent-grafts were patent after 1 month, with no mortality or limb loss. The primary patency rate with complete exclusion of the aneurysm at 6 months was 86%. Pre- and postprocedural noninvasive arterial studies were available in 10 patients, demonstrating improvement of the ankle-brachial index from 0.96 +/- 0.41 to 1.17 +/- 0.18, respectively (P = .06). CONCLUSIONS: Endovascular stent-graft repair of PAAs is a feasible treatment option. However, further follow-up studies regarding the durability of results are required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vitro study evaluated the performance of three ceramic and two commonly used polishing methods on two CAD/CAM ceramics. Surface roughness and quality were compared. A glazed group (GLGR) of each ceramic material served as reference. One-hundred and twenty specimens of VITABLOCS Mark II (VITA) and 120 specimens of IPS Empress CAD (IPS) were roughened in a standardized manner. Twenty VITA and 20 IPS specimens were glazed (VITA Akzent Glaze/Empress Universal Glaze). Five polishing methods were investigated (n=20/group): 1) EVE Diacera W11DC-Set (EVE), 2) JOTA 9812-Set (JOTA), 3) OptraFine-System (OFI), 4) Sof-Lex 2382 discs (SOF) and 5) Brownie/Greenie/Occlubrush (BGO). Polishing quality was measured with a surface roughness meter (Ra and Rz values). The significance level was set at alpha=0.05. Kruskal Wallis tests and pairwise Wilcoxon rank sum tests with Bonferroni-Holm adjustment were used. Qualitative surface evaluation of representative specimens was done with SEM. On VITA ceramics, SOF produced lower Ra (p<0.00001) but higher Rz values than GLGR (p=0.003); EVE, JOTA, OFI and BGO yielded significantly higher Ra and Rz values than GLGR. On IPS ceramics, SOF and JOTA exhibited lower Ra values than GLGR (p<0.0001). Equivalent Ra but significantly higher Rz values occurred between GLGR and EVE, OFI or BGO. VITA and IPS exhibited the smoothest surfaces when polished with SOF. Nevertheless, ceramic polishing systems are still of interest to clinicians using CAD/CAM, as these methods are universally applicable and showed an increased durability compared to the investigated silicon polishers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recent period, operative mortality of isolated aortic valve replacement for aortic stenosis varies between 1–3% in low-risk patients younger than 70 years and between 4 and 8% in selected older adults. Long-term survival following aortic valve replacement is close to that observed in a control population of similar age. Numerous observational studies have consistently demonstrated that corrective surgery in symptomatic patients is invariably followed by a subjective improvement in quality of life and a substantial increase in survival rates. More recently, transcatheter aortic valve implantation (TAVI) has been demonstrated to be feasible in patients with high surgical risk using either a retrograde transfemoral or transsubclavian approach or an antegrade, transapical access. Reported 30-day mortality ranges between 5 and 15%) and is acceptable when compared to the risk predicted by the logistic EuroSCORE (varying between 20 and 35%) and the STS Score, although the EuroScore has been shown to markedly overestimate the effective operative risk. One major concern remains the high rate of paravalvular regurgitation which is observed in up to 85% of the patients and which requires further follow-up and critical evaluation. In addition, long-term durability of these valves with a focus on the effects of crimping remains to be addressed, although 3-5 year results are promising. Sutureless biological valves were designed to simplify and significantly accelerate the surgical replacement of a diseased valve and allow complete excision of the calcified native valve. Until now, there are 3 different sutureless prostheses that have been approved. The 3f Enable valve from ATS-Medtronic received CE market approval in 2010, the Perceval S from Sorin during Q1 of 2011 and the intuity sutureless prosthesis from Edwards in 2012. All these devices aim to facilitate valve surgery and therefore have the potential to decrease the invasivness and to shorten the conventional procedure without compromise in term of excision of the diseased valve. This review summarizes the history and the current knowledge of sutureless valve technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die chronisch-kritische Beinischämie (CLI) ist die schwerste Form der peripher-arteriellen Verschlusskrankheit und geht mit einem erhöhten Risiko für letale kardiovaskuläre Ereignisse einher. Die meisten Patienten überleben aber die ersten Jahre nach Diagnosestellung und sind für den Erhalt ihrer Selbständigkeit auf eine nachhaltige Verbesserung der Beindurchblutung angewiesen. Dieser CME-Artikel fasst die chirurgischen und endovaskulären Optionen zur Revaskularisierung zusammen und geht auf deren Nachhaltigkeit bei CLI ein. Grenzen der verfügbaren Evidenz werden aufgezeigt. Sie beruhen vor allem auf dem Fehlen einer einheitlichen Definition des Behandlungserfolges. Ein klinisch orientierter Lösungsvorschlag wird diskutiert, der helfen könnte, die verschiedenen Behandlungsindikationen zu schärfen. Da sich aber nur die wenigsten Patienten gleich gut für verschiedene Verfahren eignen, werden CLI-Patienten auch in Zukunft am besten in einem interdisziplinär arbeitenden Team betreut sein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Durability of protection and long-term quality of life (QoL) are critical outcome parameters of abdominal aortic aneurysm (AAA) repair. The aim of the present study was to compare results of endovascular and open aneurysm repair (EVAR and OR) with adjusted standard populations, including stratification for urgency of presentation. METHODS: Retrospective analysis of prospectively collected data of 401 consecutive patients presenting with AAA between January 1998 and December 2002. Cross-sectional follow up was 58 +/- 29 months. Patients were grouped into three cohorts: elective EVAR (n = 68), elective OR (n = 244), and emergency OR (including symptomatic and ruptured AAA, n = 89). Endpoints were perioperative (i.e., 30 days or in-hospital) and late mortality rates, as well as long-term QoL as assessed by the Short Form health survey questionnaire (SF-36). RESULTS: Mean age was lower in the elective OR cohort (66 +/- 10 years) than in the EVAR cohort (72 +/- 7 years; p < .05). Perioperative mortality rates were 4.4%, 0.4%, and 10.1%, for the EVAR, elective OR, and emergency OR cohorts, respectively (p < .05). Corresponding cumulative survival rates after 4 years were 67%, 89%, and 69%, respectively. Long-term QoL SF-36 scores were in all cohorts similar to age- and gender-adjusted standard populations, which score between 85 and 115: 99.6 +/- 35.8 (EVAR), 101.3 +/- 32.4 (elective OR), and 100.4 +/- 36.5 (emergency OR). CONCLUSIONS: Long-term QoL is not permanently impaired after AAA repair, but returns in long-term survivors to what would be expected in a standard population. In this respect, differences were found neither between EVAR and OR, nor between elective and emergency repair. Perioperative mortality rates were highest in patients undergoing emergency OR. The outlook for such patients after the perioperative period, however, was similar to that for patients undergoing elective repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND: The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS: The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronary artery disease who underwent AMS implantation. Angiography and intravascular ultrasound (IVUS) were conducted immediately after AMS deployment and at 4 months. Eight patients who did not require repeat revascularization at 4 months underwent late angiographic and IVUS follow-up from 12 to 28 months. RESULTS: The AMS was well-expanded upon deployment without immediate recoil. The major contributors for restenosis as detected by IVUS at 4 months were: decrease of external elastic membrane volume (42%), extra-stent neointima (13%), and intra-stent neointima (45%). From 4 months to late follow-up, paired IVUS analysis demonstrated complete stent degradation with durability of the 4-month IVUS indexes. The neointima was reduced by 3.6 +/- 5.2 mm(3), with an increase in the stent cross sectional area of 0.5 +/- 1.0 mm(2) (p = NS). The median in-stent minimal lumen diameter was increased from 1.87 to 2.17 mm at long-term follow-up. The median angiographic late loss was reduced from 0.62 to 0.40 mm by quantitative coronary angiography from 4 months to late follow-up. CONCLUSIONS: Intravascular ultrasound imaging supports the safety profile of AMS with degradation at 4 months and maintains durability of the results without any early or late adverse findings. Slower degradation is warranted to provide sufficient radial force to improve long-term patency rates of the AMS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endovascular aneurysm repair has matured significantly over the last 20 years and is becoming increasingly popular as a minimally invasive treatment option for patients with abdominal aortic aneurysms (AAA). Long-term durability of this fascinating treatment, however, is in doubt as continuing aneurysmal degeneration of the aortoiliac graft attachment zones is clearly associated with late adverse sequelae. In recent years, our growing understanding of the physiopathology of AAA formation has facilitated scrutiny of various potential drug treatment concepts. In this article we review the mechanical and biological challenges associated with endovascular treatment of infrarenal AAAs and discuss potential approaches to ongoing aneurysmal degeneration, which hampers long-term outcomes of this minimally invasive therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Antiretroviral drugs have been shown to reduce risk of mother-to-child transmission of human immunodeficiency virus (HIV) and are also widely used for post-exposure prophylaxis for parenteral and sexual exposures. Sexual transmission may be lower in couples in which one partner is infected with HIV and the other is not and the infected partner is on antiretroviral therapy (ART). OBJECTIVES To determine if ART use in an HIV-infected member of an HIV-discordant couple is associated with lower risk of HIV transmission to the uninfected partner compared to untreated discordant couples. SEARCH METHODS We used standard Cochrane methods to search electronic databases and conference proceedings with relevant search terms without limits to language. SELECTION CRITERIA Randomised controlled trials (RCT), cohort studies and case-control studies of HIV-discordant couples in which the HIV-infected member of the couple was being treated or not treated with ART DATA COLLECTION AND ANALYSIS: Abstracts of all trials identified by electronic or bibliographic scanning were examined independently by two authors. We initially identified 3,833 references and examined 87 in detail for study eligibility. Data were abstracted independently using a standardised abstraction form. MAIN RESULTS One RCT and nine observational studies were included in the review. These ten studies identified 2,112 episodes of HIV transmission, 1,016 among treated couples and 1,096 among untreated couples. The rate ratio for the single randomised controlled trial was 0.04 [95% CI 0.00, 0.27]. All index partners in this study had CD4 cell counts at baseline of 350-550 cells/µL. Similarly, the summary rate ratio for the nine observational studies was 0.58 [95% CI 0.35, 0.96], with substantial heterogeneity (I(2)=64%). After excluding two studies with inadequate person-time data, we estimated a summary rate ratio of 0.36 [95% CI 0.17, 0.75] with substantial heterogeneity (I(2)=62%). We also performed subgroup analyses among the observational studies to see if the effect of ART on prevention of HIV differed by the index partner's CD4 cell count. Among couples in which the infected partner had ≥350 CD4 cells/µL, we estimated a rate ratio of 0.12 [95% CI 0.01, 1.99]. In this subgroup, there were 247 transmissions in untreated couples and 30 in treated couples. AUTHORS' CONCLUSIONS ART is a potent intervention for prevention of HIV in discordant couples in which the index partner has ≤550 CD4 cells/µL. A recent multicentre RCT confirms the suspected benefit seen in earlier observational studies and reported in more recent ones. Questions remain about durability of protection, the balance of benefits and adverse events associated with earlier therapy, long-term adherence and transmission of ART-resistant strains to partners. Resource limitations and implementation challenges must also be addressed.Counselling, support, and follow up, as well as mutual disclosure, may have a role in supporting adherence, so programmes should be designed with these components. In addition to ART provision, the operational aspects of delivering such programmes must be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) constitutes a relatively new treatment option for the patients with severe symptomatic aortic stenosis. Evidence from registries and randomized control trials has underscored the value of this treatment in inoperable and high risk populations, while new developments in valve technology and TAVR enabling devices have reduced the risk of complications, simplified the procedure, and broadened the applications of this therapy. The initial promising clinical results and the potential of an effective less invasive treatment of aortic stenosis has not only created high expectations but also the need to address the pitfalls of TAVR technology. The evolving knowledge concerning the groups of patients who would benefit from this treatment, the limited long term follow-up data, the concerns about devices' long term durability, and the severity of complications remain important caveats which restrict the widespread clinical adoption of TAVR. The aim of this review article is to present the recent advances, highlight the limitations of TAVR technology, and discuss the future perspectives in this rapidly evolving field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The effectiveness and durability of endovascular revascularization therapies for chronic critical limb ischemia (CLI) are challenged by the extensive burden of infrapopliteal arterial disease and lesion-related characteristics (e.g., severe calcification, chronic total occlusions), which frequently result in poor clinical outcomes. While infrapopliteal vessel patency directly affects pain relief and wound healing, sustained patency and extravascular care both contribute to the ultimate "patient-centric" outcomes of functional limb preservation, mobility and quality of life (QoL). METHODS/DESIGN IN.PACT DEEP is a 2:1 randomized controlled trial designed to assess the efficacy and safety of infrapopliteal arterial revascularization between the IN.PACT Amphirion™ paclitaxel drug-eluting balloon (IA-DEB) and standard balloon angioplasty (PTA) in patients with Rutherford Class 4-5-6 CLI. DISCUSSION This multicenter trial has enrolled 358 patients at 13 European centers with independent angiographic core lab adjudication of the primary efficacy endpoint of target lesion late luminal loss (LLL) and clinically driven target lesion revascularization (TLR) in major amputation-free surviving patients through 12-months. An independent wound core lab will evaluate all ischemic wounds to assess the extent of healing and time to healing at 1, 6, and 12 months. A QoL questionnaire including a pain scale will assess changes from baseline scores through 12 months. A Clinical Events Committee and Data Safety Monitoring Board will adjudicate the composite primary safety endpoints of all-cause death, major amputation, and clinically driven TLR at 6 months and other trial endpoints and supervise patient safety throughout the study. All patients will be followed for 5 years. A literature review is presented of the current status of endovascular treatment of CLI with drug-eluting balloon and standard PTA. The rationale and design of the IN.PACT DEEP Trial are discussed. IN.PACT DEEP is a milestone, prospective, randomized, robust, independent core lab-adjudicated CLI trial that will evaluate the role of a new infrapopliteal revascularization technology, the IA-DEB, compared to PTA. It will assess the overall impact on infrapopliteal artery patency, limb salvage, wound healing, pain control, QoL, and patient mobility. The 1-year results of the adjudicated co-primary and secondary endpoints will be available in 2014. TRIAL REGISTRATION NCT00941733