58 resultados para Dual energy Xray Absorptiometry

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the first part of this methodological study eleven metacarpi of 9 skeletally normal horses were examined from 4 directions by dual energy x-ray absorptiometry (DXA). The differences between the dorsopalmar-palmarodorsal and lateromedial-mediolateral (opposite sites) bone mineral density (BMD) values were found to be nonsignificant. In the second part of the study the precision of the Norland XR-26 densitometer was tested by measuring 34 metacarpal bones and 34 proximal phalanges, each of them three times, from a single direction. The difference between the individual measurements of the first phalanges and of the metacarpal bones originating from the right or the left side of the same horse were not significant, nor did the age or breed have a significant effect on BMD or bone mineral content (BMC). However, both BMD and BMC are greater in the metacarpal bones than in the proximal phalanges and are higher in geldings than in mares or to stallions, while the BMD or BMC values of mares and stallions did not differ from each other significantly. These data point to the necessity of further BMD studies in a higher number of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the effect of age and disease on mineral distribution at the distal third of the tibia, bone mineral content (BMC) and bone mineral density (BMD) were measured at lumbar spine (spine), femoral neck (neck), and diaphysis (Dia) and distal epiphysis (Epi) of the tibia in 89 healthy control women of different age groups (20-29, n = 12; 30-39, n = 11; 40-44, n = 12; 45-49, n = 12; 50-54, n = 12; 55-59, n = 10; 60-69, n = 11; 70-79, n = 9), in 25 women with untreated vertebral osteoporosis (VOP), and in 19 women with primary hyperparathyroidism (PHPT) using dual-energy x-ray absorptiometry (DXA; Hologic QDR 1000 and standard spine software). A soft tissue simulator was used to compensate for heterogeneity of soft tissue thickness around the leg. Tibia was scanned over a length of 130 mm from the ankle joint, fibula being excluded from analysis. For BMC and BMD, 10 sections 13 mm each were analyzed separately and then pooled to define the epiphysis (Epi 13-52 mm) and diaphysis area (Dia 91-130 mm). Precision after repositioning was 1.9 and 2.1% for Epi and Dia, respectively. In the control group, at any site there was no significant difference between age groups 20-29 and 30-39, which thus were pooled to define the peak bone mass (PBM).(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sequential studies of osteopenic bone disease in small animals require the availability of non-invasive, accurate and precise methods to assess bone mineral content (BMC) and bone mineral density (BMD). Dual-energy X-ray absorptiometry (DXA), which is currently used in humans for this purpose, can also be applied to small animals by means of adapted software. Precision and accuracy of DXA was evaluated in 10 rats weighing 50-265 g. The rats were anesthetized with a mixture of ketamine-xylazine administrated intraperitoneally. Each rat was scanned six times consecutively in the antero-posterior incidence after repositioning using the rat whole-body software for determination of whole-body BMC and BMD (Hologic QDR 1000, software version 5.52). Scan duration was 10-20 min depending on rat size. After the last measurement, rats were sacrificed and soft tissues were removed by dermestid beetles. Skeletons were then scanned in vitro (ultra high resolution software, version 4.47). Bones were subsequently ashed and dissolved in hydrochloric acid and total body calcium directly assayed by atomic absorption spectrophotometry (TBCa[chem]). Total body calcium was also calculated from the DXA whole-body in vivo measurement (TBCa[DXA]) and from the ultra high resolution measurement (TBCa[UH]) under the assumption that calcium accounts for 40.5% of the BMC expressed as hydroxyapatite. Precision error for whole-body BMC and BMD (mean +/- S.D.) was 1.3% and 1.5%, respectively. Simple regression analysis between TBCa[DXA] or TBCa[UH] and TBCa[chem] revealed tight correlations (n = 0.991 and 0.996, respectively), with slopes and intercepts which were significantly different from 1 and 0, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To report our initial experience with dual-energy computed-tomography (CT) cholangiography in potential donors for living-related liver transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate whether virtual non-enhanced imaging (VNI) is effective to replace true non-enhanced imaging (TNI) applying iodine removal in intravenous dual-energy CT-cholangiography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dual-energy CT provides information about how substances behave at different energies, the ability to generate virtual unenhanced datasets, and improved detection of iodine-containing substances on low-energy images. Knowing how a substance behaves at two different energies can provide information about tissue composition beyond that obtainable with single-energy techniques. The term K edge refers to the spike in attenuation that occurs at energy levels just greater than that of the K-shell binding because of the increased photoelectric absorption at these energy levels. K-edge values vary for each element, and they increase as the atomic number increases. The energy dependence of the photoelectric effect and the variability of K edges form the basis of dual-energy techniques, which may be used to detect substances such as iodine, calcium, and uric acid crystals. The closer the energy level used in imaging is to the K edge of a substance such as iodine, the more the substance attenuates. In the abdomen and pelvis, dual-energy CT may be used in the liver to increase conspicuity of hypervascular lesions; in the kidneys, to distinguish hyperattenuating cysts from enhancing renal masses and to characterize renal stone composition; in the adrenal glands, to characterize adrenal nodules; and in the pancreas, to differentiate between normal and abnormal parenchyma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0-not visualized; 3-excellent visualization). RESULTS: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3mm versus 4.9±1.3mm [P<0.05] and 3.7±1.3mm versus 2.6±0.5mm [P<0.01], respectively). CONCLUSION: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of our study was to compare the effect of dual-energy subtraction and bone suppression software alone and in combination with computer-aided detection (CAD) on the performance of human observers in lung nodule detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this retrospective study was to evaluate the impact of energy subtraction (ES) chest radiography on the detection of pulmonary nodules and masses in daily routine. Seventy-seven patients and 25 healthy subjects were examined with a single exposure digital radiography system. Five blinded readers evaluated first the non-subtracted PA and lateral chest radiographs alone and then together with the subtracted PA soft tissue images. The size, location and number of lung nodules or masses were registered with the confidence level. CT was used as standard of reference. For the 200 total lesions, a sensitivity of 33.5-52.5% was found at non-subtracted and a sensitivity of 43.5-58.5% at energy-subtracted radiography, corresponding to a significant improvement in four of five readers (p < 0.05). However, in three of five readers the rate of false positives was higher with ES. With ES, sensitivity, but not the area under the alternative free-response receiver operating characteristics (AFROC) curve, showed a good correlation with reader experience (R = 0.90, p = 0.026). In four of five readers, the diagnostic confidence improved with ES (p = 0.0036). We conclude that single-exposure digital ES chest radiography improves detection of most pulmonary nodules and masses, but identification of nodules <1 cm and false-positive findings remain a problem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper focuses on the use of multi-detector row dual-energy computed tomography (DECT) in the evaluation of postmortal examinations. The use of dual energy moves postmortem CT to an entirely new dimension of diagnostic sensitivity where contrast in the image is not merely limited to X-ray attenuation differences, but may include elements of functional and tissue characterization. This additional information may be used to improve the benefit postmortem imaging can provide to supplement and simplify the conventional autopsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two technical solutions using single or dual shot offer different advantages and disadvantages for dual energy subtraction. The principles of these are explained and the main clinical applications with results are demonstrated. Elimination of overlaying bone and proof or exclusion of calcification are the primary aims of energy subtraction chest radiography, offering unique information in different clinical situations.