4 resultados para Distance measuring equipment (DME)

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a multifactor approach for performance assessment of Water Users Associations (WUAs) in Uzbekistan in order to identify the drivers for improved and effi cient performance of WUAs. The study was carried out in the Fergana Valley where the WUAs were created along the South Fergana Main Canal during the last 10 years. The farmers and the employees of 20 WUAs were questioned about the WUAs’ activities and the quantitative and qualitative data were obtained. This became a base for the calculation of 36 indicators divided into 6 groups: Water supply, technical conditions, economic conditions, social and cultural conditions, organizational conditions and information conditions. All the indicators assessed with a differentiated point system adjusted for subjectivity of several of them give the total maximal result for the associations of 250 point. The WUAs of the Fergana Valley showed the score between 145 and 219 points, what refl ects a highly diverse level of the WUAs performance in the region. The analysis of the indicators revealed that the key points of the WUA’s success are the organizational and institutional conditions including the participatory factors and awareness of both the farmers and employees about the work of WUA. The research showed that the low performance of the WUAs is always explained by the low technical and economic conditions along with weak organization and information dissemination conditions. It is clear that it is complicated to improve technical and economic conditions immediately because they are cost-based and cost-induced. However, it is possible to improve the organizational conditions and to strengthen the institutional basis via formal and information institutions which will gradually lead to improvement of economic and technical conditions of WUAs. Farmers should be involved into the WUA Governance and into the process of making common decisions and solving common problems together via proper institutions. Their awareness can also be improved by leading additional trainings for increasing farmers’ agronomic and irrigation knowledge, teaching them water saving technologies and acquainting them with the use of water measuring equipment so it can bring reliable water supply, transparent budgeting and adequate as well as equitable water allocation to the water users.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The acquisition of accurate information on the size of traits in animals is fundamental for the study of animal ecology and evolution and their management. We demonstrate how morphological traits of free-ranging animals can reliably be estimated on very large observation distances of several hundred meters by the use of ordinary digital photographic equipment and simple photogrammetric software. In our study, we estimated the length of horn annuli in free-ranging male Alpine ibex (Capra ibex) by taking already measured horn annuli of conspecifics on the same photographs as scaling units. Comparisons with hand-measured horn annuli lengths and repeatability analyses revealed a high accuracy of the photogrammetric estimates. If length estimations of specific horn annuli are based on multiple photographs measurement errors of <5.5 mm can be expected. In the current study the application of the described photogrammetric procedure increased the sample size of animals with known horn annuli length by an additional 104%. The presented photogrammetric procedure is of broad applicability and represents an easy, robust and cost-efficient method for the measuring of individuals in populations where animals are hard to capture or to approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION The new ATS/ERS consensus report recommends in vitro validation of multiple-breath inert gas washout (MBW) equipment based on a lung model with simulated physiologic conditions. We aimed to assess accuracy of two MBW setups for infants and young children using this model, and to compare functional residual capacity (FRC) from helium MBW (FRCMBW ) with FRC from plethysmography (FRCpleth ) in vivo. METHODS The MBW setups were based on ultrasonic flow meter technology. Sulfur hexafluoride and helium were used as tracer gases. We measured FRC in vitro for specific model settings with and without carbon dioxide and calculated differences of measured to generated FRC. For in vivo evaluation, difference between FRCMBW and FRCpleth was calculated in 20 healthy children, median age 6.1 years. Coefficient of variation (CV) was calculated per FRC. RESULTS In the infant model (51 runs, FRC 80-300 ml), mean (SD) relative difference between generated and measured FRCs was 0.7 (4.7) %, median CV was 4.4% for measured FRCs. In the young child model, one setting (8 runs, FRC 400 ml) showed a relative difference of up to 13%. For the remaining FRCs (42 runs, FRC 600-1,400 ml), mean (SD) relative difference was -2.0 (3.4) %; median CV was 1.4% for measured FRCs. In vivo FRCpleth exceeded FRCMBW values by 37% on average. CONCLUSIONS Both setups measure lung volumes in the intended age group reliably and reproducibly. Characteristics of different techniques should be considered when measuring lung volumes in vivo. Pediatr Pulmonol. © 2014 Wiley Periodicals, Inc.