5 resultados para Digital Library System
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVE The Short Communication presents a clinical case in which a novel procedure--the "Individualized Scanbody Technique" (IST)--was applied, starting with an intraoral digital impression and using CAD/CAM process for fabrication of ceramic reconstructions in bone level implants. MATERIAL AND METHODS A standardized scanbody was individually modified in accordance with the created emergence profile of the provisional implant-supported restoration. Due to the specific adaptation of the scanbody, the conditioned supra-implant soft tissue complex was stabilized for the intraoral optical scan process. Then, the implant platform position and the supra-implant mucosa outline were transferred into the three-dimensional data set with a digital impression system. Within the technical workflow, the ZrO2 -implant-abutment substructure could be designed virtually with predictable margins of the supra-implant mucosa. RESULTS After finalization of the 1-piece screw-retained full ceramic implant crown, the restoration demonstrated an appealing treatment outcome with harmonious soft tissue architecture. CONCLUSIONS The IST facilitates a simple and fast approach for a supra-implant mucosal outline transfer in the digital workflow. Moreover, the IST closes the interfaces in the full digital pathway.
Resumo:
The purpose of this retrospective study was to evaluate the impact of energy subtraction (ES) chest radiography on the detection of pulmonary nodules and masses in daily routine. Seventy-seven patients and 25 healthy subjects were examined with a single exposure digital radiography system. Five blinded readers evaluated first the non-subtracted PA and lateral chest radiographs alone and then together with the subtracted PA soft tissue images. The size, location and number of lung nodules or masses were registered with the confidence level. CT was used as standard of reference. For the 200 total lesions, a sensitivity of 33.5-52.5% was found at non-subtracted and a sensitivity of 43.5-58.5% at energy-subtracted radiography, corresponding to a significant improvement in four of five readers (p < 0.05). However, in three of five readers the rate of false positives was higher with ES. With ES, sensitivity, but not the area under the alternative free-response receiver operating characteristics (AFROC) curve, showed a good correlation with reader experience (R = 0.90, p = 0.026). In four of five readers, the diagnostic confidence improved with ES (p = 0.0036). We conclude that single-exposure digital ES chest radiography improves detection of most pulmonary nodules and masses, but identification of nodules <1 cm and false-positive findings remain a problem.
Resumo:
The Personal Health Assistant Project (PHA) is a pilot system implementation sponsored by the Kozani Region Governors’ Association (KRGA) and installed in one of the two major public hospitals of the city of Kozani. PHA is intended to demonstrate how a secure, networked, multipurpose electronic health and food benefits digital signage system can transform common TV sets inside patient homes or hospital rooms into health care media players and facilitate information sharing and improve administrative efficiency among private doctors, public health care providers, informal caregivers, and nutrition program private companies, while placing individual patients firmly in control of the information at hand. This case evaluation of the PHA demonstration is intended to provide critical information to other decision makers considering implementing PHA or related digital signage technology at other institutions and public hospitals around the globe.
Resumo:
INTRODUCTION About 10,000 escalator-related injuries per year result in emergency department treatment in the United States. Since the 1990s, a steady increase has been reported, but few statistics on escalator-related injuries have been published worldwide. We have therefore analyzed escalator accident statistics in admissions to our hospital in Switzerland since 2000. METHODS Using retrospective electronic patient chart analysis, we included in our study patients >16 years treated over an 11-year period. We categorized patients in terms of gender, age and associated risk factors, and classified accidents according to day, time, location and cause. Resulting trauma was categorized according to type and location. We divided post-admission treatment into surgical and conservative, and into treatment as an outpatient, in a short-stay unit, or as a hospital admission. Women and men were compared using Fisher's exact test. RESULTS We identified 173 patients with 285 discrete injuries. Of these, 87 patients (50%) were women. Fifty-three (61%) of the women and 38 (44%) of the men were >60 years old (P = 0.033). Fifty percent of the men (43/86) of the men, but only 7% (6/87) of the women showed signs of alcohol intoxication (P < 0.0001). Accidents in women occurred predominantly on Tuesdays (19/87; 22%) between 12pm and 6pm (35/87; 40%), and in men on Saturdays (16/86; 19%) between 6pm and 12am (29/86; 34%; P = 0.0097). Sixty-two percent (44/71) of the accidents were in public transport facilities and 30% (21/71) in shopping centers. The majority of injuries in women were to the lower extremities (49/87; 56%), while most accidents in men were to the head and neck (51/86; 59%; P = 0.0052). About half (90; 52%) of the patients were treated conservatively. Almost half of all patients (76, 44%) required hospital admission. Of those, 45% left the hospital within 24 hours of admission (short stay unit) and 55% stayed longer than 24 hours. CONCLUSION Escalator accidents can result in severe trauma. Significant gender differences in escalator accidents have been observed. Alcohol intoxication and age are significant risk factors in escalator-related accidents and might be possible targets for preventive measures.