24 resultados para Difficult Dialogues

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the use of the SensaScope, an S-shaped rigid fibreoptic scope with a flexible distal end, in a series of 13 patients at high risk of, or known to have, a difficult intubation. Patients received conscious sedation with midazolam or fentanyl combined with a remifentanil infusion and topical lidocaine to the oral mucosa and to the trachea via a trans-cricoid injection. Spontaneous ventilation was maintained until confirmation of tracheal intubation. In all cases, tracheal intubation was achieved using the SensaScope. The median (IQR [range]) insertion time (measured from the time the facemask was taken away from the face until an end-expiratory CO(2) reading was visible on the monitor) was 58 s (38-111 [28-300]s). In nine of the 13 cases, advancement of the SensaScope into the trachea was easy. Difficulties included a poor view associated with a bleeding diathesis and saliva, transient loss of spontaneous breathing, and difficulty in advancing the tracheal tube in a patient with unforeseen tracheal narrowing. A poor view in two patients was partially improved by a high continuous flow of oxygen. The SensaScope may be a valuable alternative to other rigid or flexible fibreoptic scopes for awake intubation of spontaneously breathing patients with a predicted difficult airway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The i-gel™ is a single-use supraglottic airway device (SAD) that allows fibreoptic-guided tracheal intubation through the device. Until now, no prospective data for this procedure are available. Therefore, in a prospective randomized controlled trial, we evaluated fibreoptic-guided tracheal intubation with a standard Rüsch™ PVC tracheal tube (TT) through the i-gel™ compared with the single-use ILMA™ (sILMA™) TT through the sILMA™ in patients with a predicted difficult airway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The single-use supraglottic airway device i-gel™ has been described in several case reports as a conduit for intubation, but no prospective data about success rates of blind intubation are available. Therefore, we performed this prospective randomized controlled trial to compare the success rate of blind tracheal intubation with a Magill PVC tube through the i-gel™ with intubation using an sILMA™ PVC tube through the single-use intubating laryngeal mask airway (sILMA™).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Video-laryngoscopes are marketed for intubation in difficult airway management. They provide a better view of the larynx and may facilitate tracheal intubation, but there is no adequately powered study comparing different types of video-laryngoscopes in a difficult airway scenario or in a simulated difficult airway situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gastrointestinal bleeding with its point of origin outside the reach of conventional gastro- and colonoscopy represents an extraordinary diagnostic and therapeutic challenge. Bleeding may originate from the small bowel distal to the duodenojejunal junction (middle gastrointestinal bleeding) or from the biliary tree (haemobilia) or from the pancreatic ductal system (haemosuccus pancreaticus). This particular type of gastrointestinal bleeding is often intermittend and caused by a variety of different pathologies. Angiography is the diagnostic method of choice for further investigation. It allows precise localization of the bleeding site and simultaneous interventional therapy (embolization/coiling). The importance of further diagnostic modalities such as scintigraphy, capsule endoscopy, push-enteroscopy and double-balloon-enteroscopy is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The single-use supraglottic airway devices LMA-Supreme (LMA-S; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) and i-gel (Intersurgical Ltd, Wokingham, Berkshire, United Kingdom) have a second tube for gastric tube insertion. Only the LMA-S has an inflatable cuff. They have the same clinical indications and might be useful for difficult airway management. This prospective, crossover, randomized controlled trial was performed in a simulated difficult airway scenario using an extrication collar limiting mouth opening and neck movement. METHODS: Sixty patients were included. Both devices were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, and adverse events. RESULTS: Success rate for the LMA-S was 95% versus 93% for the i-gel (P = 1.000). LMA-S needed shorter insertion time (34 +/- 12 s vs. 42 +/- 23 s, P = 0.024). Tidal volumes and airway leak pressure were similar (LMA-S 26 +/- 8 cm H20; i-gel 27 +/- 9 cm H20; P = 0.441). Fiberoptic view through the i-gel showed less epiglottic downfolding. Overall agreement in insertion outcome was 54 (successes) and 1 (failure) or 55 (92%) of 60 patients. The difference in success rate was 1.7% (95% CI -11.3% to 7.6%). CONCLUSIONS: Both airway devices had similar insertion success and clinical performance in the simulated difficult airway situation. The authors found less epiglottic downfolding and better fiberoptic view but longer insertion time with the i-gel. Our study shows that both devices are feasible for emergency airway management in patients with reduced neck movement and limited mouth opening.

Relevância:

20.00% 20.00%

Publicador: