80 resultados para Detection sensitivity

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Any image processing object detection algorithm somehow tries to integrate the object light (Recognition Step) and applies statistical criteria to distinguish objects of interest from other objects or from pure background (Decision Step). There are various possibilities how these two basic steps can be realized, as can be seen in the different proposed detection methods in the literature. An ideal detection algorithm should provide high recognition sensitiv ity with high decision accuracy and require a reasonable computation effort . In reality, a gain in sensitivity is usually only possible with a loss in decision accuracy and with a higher computational effort. So, automatic detection of faint streaks is still a challenge. This paper presents a detection algorithm using spatial filters simulating the geometrical form of possible streaks on a CCD image. This is realized by image convolution. The goal of this method is to generate a more or less perfect match between a streak and a filter by varying the length and orientation of the filters. The convolution answers are accepted or rejected according to an overall threshold given by the ackground statistics. This approach yields as a first result a huge amount of accepted answers due to filters partially covering streaks or remaining stars. To avoid this, a set of additional acceptance criteria has been included in the detection method. All criteria parameters are justified by background and streak statistics and they affect the detection sensitivity only marginally. Tests on images containing simulated streaks and on real images containing satellite streaks show a very promising sensitivity, reliability and running speed for this detection method. Since all method parameters are based on statistics, the true alarm, as well as the false alarm probability, are well controllable. Moreover, the proposed method does not pose any extraordinary demands on the computer hardware and on the image acquisition process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cationic and anionic electrophoretic mobilization for focusing of hemoglobins (Hb's) in the presence of 100 carrier ampholytes covering a pI range of 6.00-7.98 was studied by computer simulation at a constant current density of 300 A/m(2). Electropherograms that would be produced by whole column imaging and by single detectors placed at different locations along the focusing column are presented. Upon mobilization, peak heights of the Hb zones decrease, but the zones retain a relatively sharp constant profile and are migrating at a constant velocity. A further peak decrease occurs during readjustment at the locations of the original buffer/column interfaces, indicating that detection sensitivity is the lowest at these locations. An anionic carrier ampholyte mobility smaller than that of its cationic species produces a cathodic drift which is smaller than the transport rate used for electrophoretic mobilization. Compared to the case with equal mobilities of carrier ampholyte species, a small increase (decrease) is predicted for the cationic (anionic) mobilization rate within the focusing column. Simulation data suggest that electrophoretic mobilization after focusing and focusing with concurrent electrophoretic mobilization are comparable isotachophoretic processes that occur when there is an uninterrupted flux of an ion through the focusing column. Cathodic drift caused by unequal mobilities of the species of carrier ampholytes, electrophoretic mobilization, and decomposition occurring at the pH gradient edges are related electrophoretic processes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CE with multiple isomer sulfated-CD as selector was used for the simultaneous analysis of the stereoisomers of ketamine, norketamine, 5,6-dehydronorketamine and hydroxylated metabolites of norketamine in liquid/liquid extracts of (i) in vitro incubations with ketamine or norketamine and equine liver microsomes and (ii) plasma and urine of ponies receiving a target-controlled infusion of ketamine under isoflurane anesthesia. Hydroxynorketamine metabolites with the hydroxy group at the cyclohexanone ring could be shown to be formed stereoselectively both in vitro and in vivo. Due to the lack of standard compounds, urinary extracts were fractionated by HPLC followed by characterization of the collected fractions with CE and LC-MS(n) with 0.7 mmu mass discrimination. Comparison of LC-MS(n) data obtained with the fractions, an in vitro microsomal sample, and both pony urine and hydrolyzed pony urine led to the identification of four hydroxylated norketamine metabolites with hydroxylation at the cyclohexanone ring, two with hydroxylation at the aromatic ring and four hydroxylated metabolites of ketamine. Due to the lower detection sensitivity, only the four hydroxynorketamine metabolites with hydroxylation at the cyclohexanone ring were observed by CE. The data suggest that demethylation of ketamine followed by hydroxylation of norketamine at the cyclohexanone ring is the major metabolic pathway in equine species and that the ketamine metabolism is highly stereoselective.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

High-resolution chemical depth profiling measurements of copper films are presented. The 10 μm thick copper test samples were electrodeposited on a Si-supported Cu seed under galvanostatic conditions in the presence of particular plating additives (SPS, Imep, PEI, and PAG) used in the semiconductor industry for the on-chip metallization of interconnects. To probe the trend of these plating additives toward inclusion into the deposit upon growth, quantitative elemental mass spectrometric measurements at trace level concentration were conducted by using a sensitive miniature laser ablation ionization mass spectrometer (LIMS), originally designed and developed for in situ space exploration. An ultrashort pulsed laser system (τ ∼ 190 fs, λ = 775 nm) was used for ablation and ionization of sample material. We show that with our LIMS system, quantitative chemical mass spectrometric analysis with an ablation rate at the subnanometer level per single laser shot can be conducted. The measurement capabilities of our instrument, including the high vertical depth resolution coupled with high detection sensitivity of ∼10 ppb, high dynamic range ≥10(8), measurement accuracy and precision, is of considerable interest in various fields of application, where investigations with high lateral and vertical resolution of the chemical composition of solid materials are required, these include, e.g., wafers from semiconductor industry or studies on space weathered samples in space research.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Space debris in geostationary orbits may be detected with optical telescopes when the objects are illuminated by the Sun. The advantage compared to Radar can be found in the illumination: radar illuminates the objects and thus the detection sensitivity depletest proportional to the fourth power of the d istance. The German Space Operation Center, GSOC, together with the Astronomical Institute of the University of Bern, AIUB, are setting up a telescope system called SMARTnet to demonstrate the capability of performing geostationary surveillance. Such a telescope system will consist of two telescopes on one mount: a smaller telescope with an aperture of 20cm will serve for fast survey while the larger one, a telescope with an aperture of 50cm, will be used for follow-up observations. The telescopes will be operated by GSOC from Oberpfaffenhofen by the internal monitoring and control system called SMARTnetMAC. The observation plan will be generated by MARTnetPlanning seven days in advance by applying an optimized planning scheduler, taking into account fault time like cloudy nights, priority of objects etc. From each picture taken, stars will be identified and everything not being a star is treated as a possible object. If the same object can be identified on multiple pictures within a short time span, the trace is called a tracklet. In the next step, several tracklets will be correlated to identify individual objects, ephemeris data for these objects are generated and catalogued . This will allow for services like collision avoidance to ensure safe operations for GSOC’s satellites. The complete data processing chain is handled by BACARDI, the backbone catalogue of relational debris information and is presented as a poster.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the performance of the DIAGNOdent pen laser fluorescence device (LFpen) in comparison with visual examination (VE), bitewing radiographs (BW) and visual examination combined with bitewing radiographs (VEBW) in detecting secondary approximal caries associated with composite restorations. In total, 60 approximal surfaces from 43 permanent molars with composite restorations were assessed twice by two examiners using the LFpen, VE, BW and VEBW. After histological preparation and hardness measurements, the sample was assigned to either a crown or root caries group, depending on the location of the lesions as the gold standard. For crown caries at D1, the highest values of specificity and sensitivity were observed for the LFpen at a cutoff value of 18 (1.00) and for the VEBW (0.89). At D3 (cutoff of 30), the LFpen showed the highest values of sensitivity and specificity. For root caries, the LFpen and VEBW showed the highest values of specificity (0.54), sensitivity (0.81) and accuracy (0.69). The Spearman rank correlation coefficients for crown/root caries with histology were 0.54/0.37 (LFpen), 0.29/0.10 (BW), 0.29/0.18 (VE) and 0.23/0.37 (VEBW). For the LFpen, the ICC varied from 0.80 (interexaminer) to 0.97 (intraexaminer B); the kappa value was 0.19 for BW and 0.35 for VE (interexaminer). Intraexaminer kappa values for BW were 0.25 (A) and 0.29 (B), and those for VE were 0.31 (A) and 0.32 (B). The LFpen device exhibited a performance comparable to that of conventional methods but with higher interexaminer reproducibility. Therefore, the LFpen should be considered an auxiliary method for the detection of secondary approximal caries associated with composite restorations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this randomised clinical trial was to investigate if a laser fluorescence device is able to discriminate between sound and carious approximal sites and between enamel and dentinal lesions, as well as to find appropriate cut-off values. METHODS: One hundred and seventeen sound or uncavitated carious sites in permanent molars were visually and radiographically examined, then either opened or not, after which their laser fluorescence was measured. Forty-three lesions were opened, the caries removed and the clinically identified caries depths were registered in addition to the radiographical scoring. Seventy-four sites were radiographically deemed sound or had enamel caries and were not opened. Here, the radiographical scorings were registered. RESULTS: Taking the radiographic scoring as gold standard for all investigated approximal sites, sound sites (D(0), n=40) showed significantly lower laser fluorescence measurements than carious sites (D(1-4), n=77) (Mann-Whitney test, P<0.025) suggesting a cut-off at 7 (sensitivity=0.68, specificity=0.7). Comparing measurements of D(0-2) (n=74) and D(3,4) (n=43), the results were also different by a statistically significant amount (P<0.025) and the cut-off calculated to be 16 (sensitivity=0.6, specificity=0.84). A fair positive correlation between laser fluorescence values and radiographical scoring was found (rho=+0.47, P<0.01). Analysing the 43 opened lesions with their clinically found lesion depths as gold standard, there was a fair positive correlation to the laser fluorescence values (rho=+0.34, P=0.03) and a moderately strong correlation to the radiographic scoring (rho=+0.67, P<0.01). CONCLUSION: The device may be an adjunct tool in the approximal detection of caries along with established procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this in vitro study was to compare the performance of two laser fluorescence devices (LF, LFpen), conventional visual criteria (VE), ICDAS and radiographic examination on occlusal surfaces of primary teeth. Thirty-seven primary human molars were selected from a pool of extracted teeth, which were stored frozen at -20°C until use. Teeth were assessed twice by two experienced examiners using laser fluorescence devices (LF and LFpen), conventional visual criteria, ICDAS and bitewing radiographs, with a 2-week interval between measurements. After measurement, the teeth were histologically prepared and assessed for caries extension. The highest sensitivity was observed for ICDAS at D(1) and D(3) thresholds, with no statistically significant difference when compared to the LF devices, except at the D(3) threshold. Bitewing radiographs presented the lowest values of sensitivity. Specificity at D(1) was higher for LFpen (0.90) and for VE at D(3) (0.94). When VE was combined with LFpen the post-test probabilities were the highest (94.0% and 89.2% at D(1) and D(3) thresholds, respectively). High values were observed for the combination of ICDAS and LFpen (92.0% and 80.0%, respectively). LF and LFpen showed the highest values of ICC for interexaminer reproducibility. However, regarding ICDAS, BW and VE, intraexaminer reproducibility was not the same for the two examiners. After primary visual inspection using ICDAS or not, the use of LFpen may aid in the detection of occlusal caries in primary teeth. Bitewing radiographs may be indicated only for approximal caries detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to evaluate the influence of professional prophylactic methods on the DIAGNOdent 2095, DIAGNOdent 2190 and VistaProof performance in detecting occlusal caries. Assessments were performed in 110 permanent teeth at baseline and after bicarbonate jet or prophylactic paste and rinsing. Performance in terms of sensitivity improved after rinsing of the occlusal surfaces when the prophylactic paste was used. However, the sodium bicarbonate jet did not significantly influence the performance of the fluorescence-based methods. It can be concluded that different professional prophylactic methods can significantly influence the performance of fluorescence-based methods for occlusal caries detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An indirect enzyme-linked immunosorbent assay (ELISA) was modified and validated to detect antibodies against Salmonella Abortusovis in naturally infected sheep. The ELISA was validated with 44 positive and 45 negative control serum samples. Compared with the immunoblot, the sensitivity and specificity of the assay were 98% and 100%, respectively. To follow antibody levels over time, samples from 12 infected ewes were collected at 1, 3, and 10 months after abortion. All animals showed antibody levels above the cutoff value throughout the observation period. One and 3 months after abortion, high antibody levels could be detected in all but one animal, whereas after 10 months, 9 animals had markedly lower but still positive antibody levels. The test characteristics and evidence for the persistence of detectable antibody levels in all infected animals for up to 10 months indicates that the ELISA can be used for herd surveillance testing.