7 resultados para Designer-médiateur
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Since the late 1990s the illicit drug market has undergone considerable change: along with the traditional drugs of abuse that still dominate, more than 100 psychotropic substances designed to bypass controlled substances legislation have appeared and led to intoxications and fatalities. Starting from the huge class of phenylalkylamines, containing many subgroups, the spectrum of structures has grown from tryptamines, piperazines, phenylcyclohexyl derivates and pyrrolidinophenones to synthetic cannabinoids and the first synthetic cocaine. Due to the small prevalence and high number of unknown substances, the detection of new designer drugs is a challenge for clinical and forensic toxicologists. Standard screening procedures might fail because a recently discovered or yet unknown substance has not been incorporated in the library used. Nevertheless, many metabolism studies, case reports, screening methods and substance-profiling papers concentrating on single compounds have been published. This review provides an overview of the developed bioanalytical and analytical methods, the matrices used, sample-preparation procedures, concentration of analytes in case of intoxication and also gives a résumé of immunoassay experiences. Additionally, six screening methods for biological matrices with a larger spectrum of analytes are described in more detail.
Resumo:
Since the late 1990s and early 2000s, derivatives of well-known designer drugs as well as new psychoactive compounds have been sold on the illicit drug market and have led to intoxications and fatalities. The LC-MS/MS screening method presented covers 31 new designer drugs as well as cathinone, methcathinone, phencyclidine, and ketamine which were included to complete the screening spectrum. All but the last two are modified molecular structures of amphetamine, tryptamine, or piperazine. Among the amphetamine derivatives are cathinone, methcathinone, 3,4-DMA, 2,5-DMA, DOB, DOET, DOM, ethylamphetamine, MDDMA, 4-MTA, PMA, PMMA, 3,4,5-TMA, TMA-6 and members of the 2C group: 2C-B, 2C-D, 2C-H, 2C-I, 2C-P, 2C-T-2, 2C-T-4, and 2C-T-7. AMT, DPT, DiPT, MiPT, DMT, and 5MeO-DMT are contained in the tryptamine group, BZP, MDBP, TFMPP, mCPP, and MeOPP in the piperazine group. Using an Applied Biosystems LC-MS/MS API 365 TurboIonSpray it is possible to identify all 35 substances. After addition of internal standards and mixed-mode solid-phase extraction the analytes are separated using a Synergi Polar RP column and gradient elution with 1 mM ammonium formate and methanol/0.1% formic acid as mobile phases A and B. Data acquisition is performed in MRM mode with positive electro spray ionization. The assay is selective for all tested substances. Limits of detection were determined by analyzing S/N-ratios and are between 1.0 and 5.0 ng/mL. Matrix effects lie between 65% and 118%, extraction efficiencies range from 72% to 90%.
Resumo:
Bacterial infections represent a rapidly growing challenge to human health. Aminoglycosides are widely used broad-spectrum antibiotics, but they inflict permanent hearing loss in up to ~50% of patients by causing selective sensory hair cell loss. Here, we hypothesized that reducing aminoglycoside entry into hair cells via mechanotransducer channels would reduce ototoxicity, and therefore we synthesized 9 aminoglycosides with modifications based on biophysical properties of the hair cell mechanotransducer channel and interactions between aminoglycosides and the bacterial ribosome. Compared with the parent aminoglycoside sisomicin, all 9 derivatives displayed no or reduced ototoxicity, with the lead compound N1MS 17 times less ototoxic and with reduced penetration of hair cell mechanotransducer channels in rat cochlear cultures. Both N1MS and sisomicin suppressed growth of E. coli and K. pneumoniae, with N1MS exhibiting superior activity against extended spectrum β lactamase producers, despite diminished activity against P. aeruginosa and S. aureus. Moreover, systemic sisomicin treatment of mice resulted in 75% to 85% hair cell loss and profound hearing loss, whereas N1MS treatment preserved both hair cells and hearing. Finally, in mice with E. coli-infected bladders, systemic N1MS treatment eliminated bacteria from urinary tract tissues and serially collected urine samples, without compromising auditory and kidney functions. Together, our findings establish N1MS as a nonototoxic aminoglycoside and support targeted modification as a promising approach to generating nonototoxic antibiotics.
Resumo:
Erosive tooth wear in children is a common condition. The overlapping of erosion with mechanical forces like attrition or abrasion is probably in deciduous teeth more pronounced than in permanent teeth. Early erosive damage to the permanent teeth may compromise the dentition for the entire lifetime and require extensive restorative procedures. Therefore, early diagnosis of the condition and adequate preventive measures are of importance. Knowledge of the etiological factors for erosive tooth wear is a prerequisite for such measures. In children and adolescents (like in adults) extrinsic and intrinsic factors or a combination of them are possible reasons for the condition. Such factors are frequent and extensive consumption of erosive foodstuffs and drinks, the intake of medicaments (asthma), gastro-esophageal reflux (a case history is discussed) or vomiting. But also behavioral factors like unusual eating and drinking habits, the consumption of designer drugs and socio-economic aspects are of importance.
Resumo:
During and after an erosive challenge, behavioral factors play a role in modifying the extent of erosive tooth wear. The manner that dietary acids are introduced into the mouth (gulping, sipping, use of a straw) will affect how long the teeth are in contact with the erosive challenge. The frequency and duration of exposure to an erosive agent is of paramount importance. Night-time exposure (e.g. baby bottle-feeding) to erosive agents may be particularly destructive because of the absence of salivary flow. Health-conscious individuals tend to ingest acidic drinks and juices more frequently and tend to have higher than average oral hygiene. While good oral hygiene is of proven value in the prevention of periodontal disease and dental caries, frequent toothbrushing with abrasive oral hygiene products may enhance erosive tooth wear. Unhealthy lifestyles such as consumption of designer drugs, alcopops and alcohol abuse are other important behavioral factors.
Resumo:
Screening tests for drugs of abuse are regularly used in the clinical routine. These tests identify the targeted substances very differently if tests from different manufacturers are used and sometimes also react positive after the intake of drugs which are not intended to be detected. Therefore, implausible results have to be questioned. A test result can be falsely negative, if a patient has taken a compound which is not detected by the antibody used in the test system. Chromatographic confirmation and screening assays are more laborious to perform and more demanding for the interpretation and are therefore only offered by several specialized clinical laboratories. However, their specificity is excellent and many different compounds can be detected depending on the number of compounds which are part of the mass spectra library used. If the clinical evaluation results in the differential diagnosis of an acute intoxication, screening tests for drugs of abuse can help to identify a single compound or a group of substances. The clinical picture, however, can usually not been explained by a qualitative test result. In addition, there are no published data demonstrating that these tests meaningfully influence triage, treatment, diagnosis or further therapy of a poisoned patient. The quantitative determination of specific compounds in the blood allows for example an appraisal of the prognosis and helps to indicate a specific therapy after intake of acetaminophen or methanol. New designer drugs can not at all be detected by the classic screening tests for drugs of abuse. The have to be identified by chromatographic methods.
Resumo:
Stray light contamination reduces considerably the precision of photometric of faint stars for low altitude spaceborne observatories. When measuring faint objects, the necessity of coping with stray light contamination arises in order to avoid systematic impacts on low signal-to-noise images. Stray light contamination can be represented by a flat offset in CCD data. Mitigation techniques begin by a comprehensive study during the design phase, followed by the use of target pointing optimisation and post-processing methods. We present a code that aims at simulating the stray-light contamination in low-Earth orbit coming from reflexion of solar light by the Earth. StrAy Light SimulAtor (SALSA) is a tool intended to be used at an early stage as a tool to evaluate the effective visible region in the sky and, therefore to optimise the observation sequence. SALSA can compute Earth stray light contamination for significant periods of time allowing missionwide parameters to be optimised (e.g. impose constraints on the point source transmission function (PST) and/or on the altitude of the satellite). It can also be used to study the behaviour of the stray light at different seasons or latitudes. Given the position of the satellite with respect to the Earth and the Sun, SALSA computes the stray light at the entrance of the telescope following a geometrical technique. After characterising the illuminated region of the Earth, the portion of illuminated Earth that affects the satellite is calculated. Then, the flux of reflected solar photons is evaluated at the entrance of the telescope. Using the PST of the instrument, the final stray light contamination at the detector is calculated. The analysis tools include time series analysis of the contamination, evaluation of the sky coverage and an objects visibility predictor. Effects of the South Atlantic Anomaly and of any shutdown periods of the instrument can be added. Several designs or mission concepts can be easily tested and compared. The code is not thought as a stand-alone mission designer. Its mandatory inputs are a time series describing the trajectory of the satellite and the characteristics of the instrument. This software suite has been applied to the design and analysis of CHEOPS (CHaracterizing ExOPlanet Satellite). This mission requires very high precision photometry to detect very shallow transits of exoplanets. Different altitudes and characteristics of the detector have been studied in order to find the best parameters, that reduce the effect of contamination. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.