10 resultados para Design procedures

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Percutaneous nephrolithotomy (PCNL) for the treatment of renal stones and other related renal diseases has proved its efficacy and has stood the test of time compared with open surgical methods and extracorporal shock wave lithotripsy. However, access to the collecting system of the kidney is not easy because the available intra-operative image modalities only provide a two dimensional view of the surgical scenario. With this lack of visual information, several punctures are often necessary which, increases the risk of renal bleeding, splanchnic, vascular or pulmonary injury, or damage to the collecting system which sometimes makes the continuation of the procedure impossible. In order to address this problem, this paper proposes a workflow for introduction of a stereotactic needle guidance system for PCNL procedures. An analysis of the imposed clinical requirements, and a instrument guidance approach to provide the physician with a more intuitive planning and visual guidance to access the collecting system of the kidney are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Randomization is a key step in reducing selection bias during the treatment allocation phase in randomized clinical trials. The process of randomization follows specific steps, which include generation of the randomization list, allocation concealment, and implementation of randomization. The phenomenon in the dental and orthodontic literature of characterizing treatment allocation as random is frequent; however, often the randomization procedures followed are not appropriate. Randomization methods assign, at random, treatment to the trial arms without foreknowledge of allocation by either the participants or the investigators thus reducing selection bias. Randomization entails generation of random allocation, allocation concealment, and the actual methodology of implementing treatment allocation randomly and unpredictably. Most popular randomization methods include some form of restricted and/or stratified randomization. This article introduces the reasons, which make randomization an integral part of solid clinical trial methodology, and presents the main randomization schemes applicable to clinical trials in orthodontics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Baxter Amicus Version 2.51 (A) and the Gambro BCT Trima Accel Version 5.0 (T) cell separators may produce multiple platelet (PLT) concentrates within a single donation. STUDY DESIGN AND METHODS: The single-needle multiple plateletpheresis procedures of the two devices were compared in a prospective, randomized, paired crossover study in 60 donors. The 120 donations were compared for donor comfort, collection efficiency, residual white blood cell (WBC) count, and (in selected patients) corrected count increment (CCI). RESULTS: The mean PLT yield and the resultant mean number of units per donation were significantly lower for A (6.06 x 10(11) vs. 7.48 x 10(11) and 2.57 vs. 3.19, respectively, both p < 0.001), in spite of a longer apheresis duration (89 min vs. 79 min; p < 0.001). This resulted in a higher collection rate of T (5.68 x 10(11) PLTs/hr vs. 4.10 x 10(11) PLTs/hr, p < 0.001). Residual WBC count of every unit was fewer than 5 x 10(6), but significantly fewer A-PLT donations contained more than 10(5) WBCs per unit (1 vs. 9, p = 0.008). Although the ACD-A consumption was slightly higher for A (489 mL vs. 469 mL, p = 0.04), a trend to a higher frequency of side effects was found for T (42.4% vs. 23.7%, p = 0.06). The 1-hour CCIs of 33 transfused A-PLT units were comparable with those of 43 T-PLT units (11.8 vs. 13.9, p = 0.480). CONCLUSIONS: Both cell separators showed safe collections of up to 4 PLT units per donation with adequate CCI. T produced a higher PLT yield despite shorter apheresis duration, but with slightly higher residual WBC counts and a trend to a higher side-effect frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To investigate the impact of filter design on blood flow impairment in the internal carotid artery (ICA) among patients undergoing carotid artery stenting (CAS) using filter-type emboli protection devices (EPD). METHODS: Between July 2003 and March 2007, 115 filter-protected CAS procedures were performed at an academic institution in 107 consecutive patients (78 men; mean age 68 years, range 38-87). The Angioguard, FilterWire EZ, and Spider filters were used in 68 (59%), 32 (28%), and 15 (13%) of cases, respectively. Patient characteristics, procedural and angiographic data, and outcomes were prospectively entered into an electronic database and reviewed retrospectively along with all angiograms. RESULTS: Flow impairment while the filter was in place was observed in 25 (22%) cases. The presumptive reason of flow impairment was filter obstruction in 21 (18%) instances and flow-limiting spasm at the level of the filter in 4 (4%). In all cases, flow was restored after retrieval of the filter. Flow obstruction in the ICA occurred more frequently with Angioguard (22/68; 32.3%) than with FilterWire EZ (2/32; 6.2%) or Spider (1/15; 6.7%; p = 0.004). No flow occurred in 13 (19%) procedures, all of them protected with Angioguard; no patient treated with other devices experienced this event (p = 0.007). Two (8.0%) strokes occurred in procedures associated with flow impairment, while 1 (1.1%) event was observed in the presence of preserved flow throughout the intervention (p = 0.11). CONCLUSION: Flow impairment in the ICA during filter-based CAS is common and related to the type of filter used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite widespread use of species-area relationships (SARs), dispute remains over the most representative SAR model. Using data of small-scale SARs of Estonian dry grassland communities, we address three questions: (1) Which model describes these SARs best when known artifacts are excluded? (2) How do deviating sampling procedures (marginal instead of central position of the smaller plots in relation to the largest plot; single values instead of average values; randomly located subplots instead of nested subplots) influence the properties of the SARs? (3) Are those effects likely to bias the selection of the best model? Our general dataset consisted of 16 series of nested-plots (1 cm(2)-100 m(2), any-part system), each of which comprised five series of subplots located in the four corners and the centre of the 100-m(2) plot. Data for the three pairs of compared sampling designs were generated from this dataset by subsampling. Five function types (power, quadratic power, logarithmic, Michaelis-Menten, Lomolino) were fitted with non-linear regression. In some of the communities, we found extremely high species densities (including bryophytes and lichens), namely up to eight species in 1 cm(2) and up to 140 species in 100 m(2), which appear to be the highest documented values on these scales. For SARs constructed from nested-plot average-value data, the regular power function generally was the best model, closely followed by the quadratic power function, while the logarithmic and Michaelis-Menten functions performed poorly throughout. However, the relative fit of the latter two models increased significantly relative to the respective best model when the single-value or random-sampling method was applied, however, the power function normally remained far superior. These results confirm the hypothesis that both single-value and random-sampling approaches cause artifacts by increasing stochasticity in the data, which can lead to the selection of inappropriate models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Multiple organ failure is a common complication of acute circulatory and respiratory failure. We hypothesized that therapeutic interventions used routinely in intensive care can interfere with the perfusion of the gut and the liver, and thereby increase the risk of mismatch between oxygen supply and demand. DESIGN: Prospective, observational study. SETTING: Interdisciplinary intensive care unit (ICU) of a university hospital. PATIENTS: Thirty-six patients on mechanical ventilation with acute respiratory or circulatory failure or severe infection were included. INTERVENTIONS: Insertion of a hepatic venous catheter. MEASUREMENTS AND MAIN RESULTS: Daily nursing procedures were recorded. A decrease of >or=5% in hepatic venous oxygen saturation (Sho2) was considered relevant. Observation time was 64 (29-104) hours (median [interquartile range]). The ICU stay was 11 (8-15) days, and hospital mortality was 35%. The number of periods with procedures/patient was 170 (98-268), the number of procedure-related decreases in Sho2 was 29 (13-41), and the number of decreases in Sho2 unrelated to procedures was 9 (4-19). Accordingly, procedure-related Sho2 decreases occurred 11 (7-17) times per day. Median Sho2 decrease during the procedures was 7 (5-10)%, and median increase in the gradient between mixed and hepatic venous oxygen saturation was 6 (4-9)%. Procedures that caused most Sho2 decreases were airway suctioning, assessment of level of sedation, and changing patients' position. Sho2 decreases were associated with small but significant increases in heart rate and intravascular pressures. Maximal Sequential Organ Failure Assessment scores in the ICU correlated with the number of Sho2 decreases (r: .56; p < 0.001) and with the number of procedure-related Sho2 decreases (r: .60; p < 0.001). CONCLUSIONS: Patients are exposed to repeated episodes of impaired splanchnic perfusion during routine nursing procedures. More research is needed to examine the correlation, if any, between nursing procedures and hepatic venous desaturation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cluster randomized trials (CRTs) use as the unit of randomization clusters, which are usually defined as a collection of individuals sharing some common characteristics. Common examples of clusters include entire dental practices, hospitals, schools, school classes, villages, and towns. Additionally, several measurements (repeated measurements) taken on the same individual at different time points are also considered to be clusters. In dentistry, CRTs are applicable as patients may be treated as clusters containing several individual teeth. CRTs require certain methodological procedures during sample calculation, randomization, data analysis, and reporting, which are often ignored in dental research publications. In general, due to similarity of the observations within clusters, each individual within a cluster provides less information compared with an individual in a non-clustered trial. Therefore, clustered designs require larger sample sizes compared with non-clustered randomized designs, and special statistical analyses that account for the fact that observations within clusters are correlated. It is the purpose of this article to highlight with relevant examples the important methodological characteristics of cluster randomized designs as they may be applied in orthodontics and to explain the problems that may arise if clustered observations are erroneously treated and analysed as independent (non-clustered).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Even though arthroplasty of the ankle joint is considered to be an established procedure, only about 1,300 endoprostheses are implanted in Germany annually. Arthrodeses of the ankle joint are performed almost three times more often. This may be due to the availability of the procedure - more than twice as many providers perform arthrodesis - as well as the postulated high frequency of revision procedures of arthroplasties in the literature. In those publications, however, there is often no clear differentiation between revision surgery with exchange of components, subsequent interventions due to complications and subsequent surgery not associated with complications. The German Orthopaedic Foot and Ankle Association's (D. A. F.) registry for total ankle replacement collects data pertaining to perioperative complications as well as cause, nature and extent of the subsequent interventions, and postoperative patient satisfaction. MATERIAL AND METHODS The D. A. F.'s total ankle replacement register is a nation-wide, voluntary registry. After giving written informed consent, the patients can be added to the database by participating providers. Data are collected during hospital stay for surgical treatment, during routine follow-up inspections and in the context of revision surgery. The information can be submitted in paper-based or online formats. The survey instruments are available as minimum data sets or scientific questionnaires which include patient-reported outcome measures (PROMs). The pseudonymous clinical data are collected and evaluated at the Institute for Evaluative Research in Medicine, University of Bern/Switzerland (IEFM). The patient-related data remain on the register's module server in North Rhine-Westphalia, Germany. The registry's methodology as well as the results of the revisions and patient satisfaction for 115 patients with a two year follow-up period are presented. Statistical analyses are performed with SAS™ (Version 9.4, SAS Institute, Inc., Cary, NC, USA). RESULTS About 2½ years after the register was launched there are 621 datasets on primary implantations, 1,427 on follow-ups and 121 records on re-operation available. 49 % of the patients received their implants due to post-traumatic osteoarthritis, 27 % because of a primary osteoarthritis and 15 % of patients suffered from a rheumatic disease. More than 90 % of the primary interventions proceeded without complications. Subsequent interventions were recorded for 84 patients, which corresponds to a rate of 13.5 % with respect to the primary implantations. It should be noted that these secondary procedures also include two-stage procedures not due to a complication. "True revisions" are interventions with exchange of components due to mechanical complications and/or infection and were present in 7.6 % of patients. 415 of the patients commented on their satisfaction with the operative result during the last follow-up: 89.9 % of patients evaluate their outcome as excellent or good, 9.4 % as moderate and only 0.7 % (3 patients) as poor. In these three cases a component loosening or symptomatic USG osteoarthritis was present. Two-year follow-up data using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Scale (AOFAS-AHS) are already available for 115 patients. The median AOFAS-AHS score increased from 33 points preoperatively to more than 80 points three to six months postoperatively. This increase remained nearly constant over the entire two-year follow-up period. CONCLUSION Covering less than 10 % of the approximately 240 providers in Germany and approximately 12 % of the annually implanted total ankle-replacements, the D. A. F.-register is still far from being seen as a national registry. Nevertheless, geographical coverage and inclusion of "high-" (more than 100 total ankle replacements a year) and "low-volume surgeons" (less than 5 total ankle replacements a year) make the register representative for Germany. The registry data show that the number of subsequent interventions and in particular the "true revision" procedures are markedly lower than the 20 % often postulated in the literature. In addition, a high level of patient satisfaction over the short and medium term is recorded. From the perspective of the authors, these results indicate that total ankle arthroplasty - given a correct indication and appropriate selection of patients - is not inferior to an ankle arthrodesis concerning patients' satisfaction and function. First valid survival rates can be expected about 10 years after the register's start.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Research ethics approvals, procedures and requirements for institutional research ethics committees vary considerably by country and by type of organisation. OBJECTIVE To evaluate the requirements and procedures of research ethics committees, details of patient information and informed consent based on a multicentre European trial. DESIGN Survey of European hospitals participating in the prospective observational study on chronic postsurgical pain (euCPSP) using electronic questionnaires. SETTING Twenty-four hospitals in 11 European countries. PARTICIPANTS From the 24 hospitals, 23 local investigators responded; 23 answers were analysed. OUTCOME MEASURES Comparison of research ethics procedures and committee requirements from the perspective of clinical researchers. Comparison of the institutions' procedures regarding patient information and consent. Description of further details such as costs and the duration of the approval process. RESULTS The approval process lasted from less than 2 weeks up to more than 2 months with financial fees varying between 0 and 575 &OV0556;. In 20 hospitals, a patient information sheet of variable length (half page up to two pages) was provided. Requirements for patients' informed consent differed. Written informed consent was mandatory at 12, oral at 10 and no form of consent at one hospital. Details such as enough time for consideration, possibility for withdrawal and risks/benefits of participation were provided in 25 to 30% of the institutions. CONCLUSION There is a considerable variation in the administrative requirements for approval procedures by research ethics committees in Europe. This results in variation of the extent of information and consent procedures for the patients involved. TRIAL REGISTRATION euCPSP in Clinicaltrials.gov identifier: NCT01467102; PAIN-OUT in Clinicaltrials.gov identifier: NCT02083835.