3 resultados para Dental infection

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In the past few years indications for the use of the air polishing technology have been expanded from supragingival use (airflow) to subgingival air polishing (perioflow) by the development of new low-abrasive glycine-based powders and devices with a subgingival nozzle. Several studies on the subgingival use of air polishing have been completed. On 7 June 2012, during the Europerio 7 Congress in Vienna, a consensus conference on mechanical biofilm management took place aiming to review the current evidence from the literature on the clinical relevance of the subgingival use of air polishing and to make practical recommendations for the clinician. Bernita Bush (Bern), Prof Johannes Einwag (Stuttgart), Prof Thomas Flemmig (Seattle), Carmen Lanoway (Munich), Prof Ursula Platzer (Hamburg), Prof Petra Schmage (Hamburg), Brigitte Schoeneich (Zurich), Prof Anton Sculean (Bern), Dr Clemens Walter (Basel), and Prof Jan Wennström (Gothenburg) discussed under the moderation of Klaus-Dieter Bastendorf and Christian Becker (both ADIC Association for Dental Infection Control) the available clinical studies to reach a consensus on available clinical evidence. This paper summarizes the main conclusions of the consensus conference and points to the clinical relevance of the findings for the dental practitioner.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To report meningoencephalitis as a complication after paranasal sinus surgery in 5 horses. STUDY DESIGN Case series. ANIMALS Adult horses (n = 5). METHODS Medical records (2005-2010) of 5 horses that developed neurologic signs after sinus surgery were reviewed to identify potential risk factors, cause(s), or common pathways for infection. RESULTS Underlying diseases were primary (n = 1) and secondary sinusitis (4) because of apical dental infection (1), sinus cyst (2), or masses in the ethmoturbinate region (2). Horses were treated by conventional surgical approaches and aftercare including repeated sinus lavage. Four horses had undulating pyrexia postoperatively despite antimicrobial therapy. All horses developed neurologic signs, eventually unresponsive to treatment. Suppurative meningoencephalitis was diagnosed macro- and/or microscopically on necropsy in all horses. CONCLUSION Meningitis is a rare but fatal complication after sinus surgery in horses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this prospective study was to evaluate the 5-year performance and success rate of titanium screw-type implants with the titanium plasma spray (TPS) or the sand-blasted, large grit, acid-etched (SLA) surface inserted in a two-stage sinus floor elevation (SFE) procedure in the posterior maxilla. MATERIAL AND METHODS: A total of 59 delayed SFEs were performed in 56 patients between January 1997 and December 2001, using a composite graft with autogenous bone chips combined with deproteinized bovine bone mineral (DBBM) or synthetic porous beta-tricalcium phosphate (beta-TCP). After a healing period averaging 7.75 months, 111 dental implants were inserted. After an additional 8-14-week healing period, all implants were functionally loaded with cemented crowns or fixed partial dentures. The patients were recalled at 12 and 60 months for clinical and radiographic examination. RESULTS: One patient developed an acute infection in the right maxillary sinus after SFE and did not undergo implant therapy. Two of the 111 inserted implants had to be removed because of a developing atypical facial pain, and 11 implants were lost to follow-up and were considered drop-outs. The remaining 98 implants showed favorable clinical and radiographic findings at the 5-year examination. The peri-implant soft tissues were stable over time; the mean probing depths and mean attachment levels did not change during the follow-up period. The measurement of the bone crest levels (DIB values) indicated stability as well. Based on strict success criteria, all 98 implants were considered successfully integrated, resulting in a 5-year success rate of 98% (for TPS implants 89%, for SLA implants 100%). CONCLUSION: This prospective study assessing the performance of dental implants inserted after SFE demonstrated that titanium implants can achieve and maintain successful tissue integration with high predictability for at least 5 years of follow-up in carefully selected patients.