22 resultados para Dental Impression Technique
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Prediction of dental implant torque with a fast and automatic finite element analysis: a pilot study
Resumo:
Despite its importance, implant removal torque can be assessed at present only after implantation. This paper presents a new technique to help clinicians preoperatively evaluate implant stability.
Resumo:
Because the recommendation to use flowables for posterior restorations is still a matter of debate, the objective of this study was to determine in a nationwide survey in Germany how frequently, for what indications, and for what reasons, German dentists use flowable composites in posterior teeth. In addition, the acceptance of a simplified filling technique for posterior restorations using a low stress flowable composite was evaluated. Completed questionnaires from all over Germany were returned by 1,449 dentists resulting in a response rate of 48.5%; 78.6% of whom regularly used flowable composites for posterior restorations. The most frequent indications were cavity lining (80.1%) and small Class I fillings (74.2%). Flowables were less frequently used for small Class II fillings (22.7%) or other indications (13.6%). Most frequent reasons given for the use of flowables in posterior teeth were the prevention of voids (71.7%) and superior adaptation to cavity walls (72.9%), whereas saving time was considered less important (13.8%). Based on the subjective opinion of the dentists the simplified filling technique seemed to deliver advantages compared to the methods used to date particularly with regard to good cavity adaptation and ease of use. In conclusion, resin composites are the standard material type used for posterior restorations by general dental practitioners in Germany and most dentists use flowable composites as liners.
Resumo:
Palatal scarring is assumed to be a primary cause of facial growth derangement in cleft lip and palate. Evidence supporting this hypothesis is confounded by the clinical involvement of various surgeons, and therefore definitive conclusions are not possible. In this study, we investigated the dental arch relationship in two groups, Exposed (47 children; 11.2 yrs) and Unexposed (61 children; 11.2 yrs), with a unilateral cleft lip and palate operated on by the same surgeon. The technique of hard palate repair differed between the two groups. In the Exposed group, palatal bone of the non-cleft side only was left denuded, inducing scar formation. In the Unexposed group, a vomerplasty with tight closure of the soft tissues was applied. Three raters graded the dental arch relationship and palatal morphology using the EUROCRAN Index. The dental arch relationship in the Exposed group was less favorable than in the Unexposed group (p = 0.009). Palatal morphology in both groups was comparable (p = 0.323). This study demonstrates that reduction of denuded bony areas on the palate after palatal repair with a vomer flap had a favorable effect on the dental arch relationship. For palatal morphology, no effect of the type of palatal repair was found.
Resumo:
Preliminary data have suggested that taurolidine may bear promising disinfectant properties for the therapy of bacterial infections. However, at present, the potential antibacterial effect of taurolidine on the supragingival plaque biofilm is unknown. To evaluate the antibacterial effect of taurolidine on the supragingival plaque biofilm using the vital fluorescence technique and to compare it with the effect of NaCl and chlorhexidine (CHX), 18 subjects had to refrain from all mechanical and chemical hygiene measures for 24 h. A voluminous supragingival plaque sample was taken from the buccal surfaces of the lower molars and wiped on an objective slide. The sample was then divided into three equal parts and mounted with one of the three test or control preparations (a) NaCl, (b) taurolidine 2% and (c) CHX 0.2%. After a reaction time of 2 min, the test solutions were sucked of. Subsequently, the plaque biofilm was stained with fluorescence dye and vitality of the plaque flora was evaluated under the fluorescence microscope (VF%). Plaque samples treated with NaCl showed a mean VF of 82.42 ± 6.04%. Taurolidine affected mean VF with 47.57 ± 16.60% significantly (p < 0.001, paired t test). The positive control CHX showed the lowest mean VF values (34.41 ± 14.79%; p < 0.001 compared to NaCl, p = 0.017 compared to taurolidine). Taurolidine possesses a significant antibacterial effect on the supragingival plaque biofilm which was, however, not as pronounced as that of CHX.
Resumo:
The performance of three elastomeric materials for the open monophase implant impressions technique was tested under the following clinical conditions: polyether (IM) and vinylsiloxanether without (ID) and with additional simultaneous splinting of the implant impression copings with a higher shore hardness A-silicone (IDF).
Resumo:
The aim of this study was to compare data on design and fabrication methods of removable partial dentures (RPDs) in two major cities in Greece. A questionnaire was sent to 150 randomly selected dental technicians. The participation rate was 79.3%. The anterior palatal strap, the lingual bar, and the Roach-type clasp arm designs were preferred. Half of the RPDs fabricated were retained using precision attachments. Differences between the two cities were observed in types of major maxillary connectors used, types of attachments and impression materials used, as well as the design of distal-extension RPDs. Postdoctoral education was found to have an impact on RPD fabrication. Despite the differences observed, design and fabrication of RPDs followed commonly used principles.
Resumo:
PURPOSE: Two noninvasive methods to measure dental implant stability are damping capacity assessment (Periotest) and resonance frequency analysis (Osstell). The objective of the present study was to assess the correlation of these 2 techniques in clinical use. MATERIALS AND METHODS: Implant stability of 213 clinically stable loaded and unloaded 1-stage implants in 65 patients was measured in triplicate by means of resonance frequency analysis and Periotest. Descriptive statistics as well as Pearson's, Spearman's, and intraclass correlation coefficients were calculated with SPSS 11.0.2. RESULTS: The mean values were 57.66 +/- 8.19 implant stability quotient for the resonance frequency analysis and -5.08 +/- 2.02 for the Periotest. The correlation of both measuring techniques was -0.64 (Pearson) and -0.65 (Spearman). The single-measure intraclass correlation coefficients for the ISQ and Periotest values were 0.99 and 0.88, respectively (95% CI). No significant correlation of implant length with either resonance frequency analysis or Periotest could be found. However, a significant correlation of implant diameter with both techniques was found (P < .005). The correlation of both measuring systems is moderate to good. It seems that the Periotest is more susceptible to clinical measurement variables than the Osstell device. The intraclass correlation indicated lower measurement precision for the Periotest technique. Additionally, the Periotest values differed more from the normal (Gaussian) curve of distribution than the ISQs. Both measurement techniques show a significant correlation to the implant diameter. CONCLUSION: Resonance frequency analysis appeared to be the more precise technique.
Resumo:
OBJECTIVES: To analyze the survival and success rates of implants installed utilizing the (transalveolar) osteotome technique, to compare peri-implant soft tissue parameters and marginal bone levels of osteotome-installed implants with implants placed using standard surgical procedures, and to evaluate patient-centered outcomes. MATERIAL AND METHODS: During 2000 to 2005, 252 Straumann dental implants were inserted in 181 patients. The surgical technique was a modification of the original osteotome technique presented by Summers. In addition to the clinical examination, the patients were asked to give their perception of the surgical procedure, utilizing a visual analogue scale. RESULTS: The cumulative survival rate of the osteotome-installed implants after a mean follow-up time of 3.2 years, was 97.4% (95% confidence intervals: 94.4-98.8%). From the 252 implants inserted, three were lost before loading and another three were lost in the first and second year. According to residual bone height the survival was 91.3% for implant sites with < or =4 mm residual bone height, and 90% for sites with 4 mm and 5 mm, when compared with that of 100% in sites with bone height of above 5 mm. According to implant length the survival rates were 100% for 12 mm, 98.7% for 10 mm, 98.7% for 8 mm and only 47.6% for 6 mm implants. Soft tissue parameters (pocket probing depth, probing attachment level, bleeding on probing and marginal bone levels) did not yield any differences between the osteotome-installed and the conventionally placed implants. More than 90% of the patients were satisfied with the implant therapy and would undergo similar therapy again if necessary. The cost associated with implant therapy was considered to be justified. CONCLUSION: In conclusion, the osteotome technique was a reliable method for implant insertion in the posterior maxilla, especially at sites with 5 mm or more of preoperative residual bone height and a relatively flat sinus floor.
Resumo:
Grafting of the maxillary sinus in both one- and two-stage protocols has become a highly predictable surgical technique for site development and for the placement of implants to support dentures. However, despite the predictability and high success rates reported for dental implants placed either simultaneously with or after a sinus floor elevation (SFE) procedure, complications have been reported. The aim of the following case report is to present an uncommon complication in a staged SFE procedure: the displacement of a dental implant into the maxillary sinus during insertion. As implant dentistry is becoming more and more popular among practitioners, and ever more demanding procedures for initial site development in jaws with bony deficiencies are being introduced into daily practice, the displacement of dental implants into the maxillary sinus during implant placement may become a more frequent complication. Management of this complication is presented, discussed, and evaluated in light of the current literature.
Resumo:
AIM: The aim of this study was to assess the marginal fit of crowns on the Straumann (ITI) Dental Implant System with special consideration of different casting dental materials. MATERIAL AND METHODS: Sixty porcelain-fused-to-metal crowns were fabricated: 18 crowns on standard cone abutments with an impression cylinder, partially prefabricated analogs, no coping and screw-retained (A); 18 crowns on solid abutments without an impression device, no analogs, no coping and cemented (B); and 18 crowns on solid abutments using an impression transfer cap, an analog with a shoulder, no coping and cemented (C). In each group, six crowns were made on epoxy mastercasts (Bluestar), six on synthetic plaster (Moldasynt) and six on super hard stone (Fujirock). Six additional crowns were fabricated with the transversal screw retention system onto the Octa system with impression transfer caps, metal analogs, gold copings and screw-retained (D). Impregum was used as impression material. Crowns of B and C were cemented with KetacCem. Crowns of A and D were fixed with an occlusal screw torqued at 15 N cm. Crowns were embedded, cut and polished. Under a light microscope using a magnification of x 100, the distance between the crown margin (CM) and the shoulder (marginal gap, MG) and the distance between the CM and the end of the shoulder (crown length, CL) was measured. RESULTS: MGs were 15.4+/-13.2 microm (A), 21.2+/-23.1 microm (B), 11+/-12.1 microm (C) and 10.4+/-9.3 microm (D). No statistically significantly differences using either of the casting materials were observed. CLs were -21.3+/-24.8 microm (A), 3+/-28.9 microm (B), 0.5+/-22 microm (C) and 0.1+/-15.8 microm (D). Crowns were shorter on synthetic casting materials compared with stone casts (P<0.005). CONCLUSIONS: CMs fit precisely with both cemented and screw-retained versions as well as when using no, partial or full analogs.
Optical pen-size reflectometer for monitoring of early dental erosion in native and polished enamels
Resumo:
Application of the specular reflection intensity was previously reported for the quantification of early dental erosion. Further development of the technique and assembly of the miniaturized pen-size instrument are described. The optical system was adjusted to fit into a handy device which could potentially access different positions in the oral cavity. The assembled instrument could successfully detect early erosion progression in both polished (n=70) and native (n=20) human enamels. Different severities of enamel erosion were induced by varying incubation time of polished enamel in 1% citric acid (pH=3.60, 0.5 to 10 min), while the native incisors were treated in the commercial orange juice (Tropicana Pure Premium®, pH=3.85, 10 to 60 min). The instrument provided a good differentiation between various severities of the erosion in vitro. The size of the measurement spot affected the erosion monitoring in native enamel (human incisors). The erosion measurement in the 0.7-mm (diameter) cervical spots showed systematically lower reflection intensities compared with the analysis of central and incisal small spots. The application of larger spot areas (2.3 mm) for the erosion monitoring revealed no effect (p>0.05) of the spot position on the reflection signal. High variation of the teeth susceptibility toward in vitro erosion was detected in native enamel.
Resumo:
The indications for direct resin composite restorations are nowadays extended due to the development of modern resin materials with improved material properties. However, there are still some difficulties regarding handling of resin composite material, especially in large restorations. The reconstruction of a functional and individual occlusion is difficult to achieve with direct application techniques. The aim of the present publication was to introduce a new "stamp"-technique for placing large composite restorations. The procedure of this "stamp"-technique is presented by three typical indications: large single-tooth restoration, occlusal rehabilitation of a compromised occlusal surface due to erosions and direct fibre-reinforced fixed partial denture. A step-by-step description of the technique and clinical figures illustrates the method. Large single-tooth restorations can be built-up with individual, two- piece silicone stamps. Large occlusal abrasive and/or erosive defects can be restored by copying the wax-up from the dental technician using the "stamp"-technique. Even fiber-reinforced resin-bonded fixed partial dentures can be formed with this intraoral technique with more precision and within a shorter treatment time. The presented "stamp"-technique facilitates the placement of large restoration with composite and can be recommended for the clinical use.
Resumo:
BACKGROUND Tooth root problems and periodontal diseases are common in South American camelids (SAC). The objective was to evaluate and optimize the imaging technique for dental radiography in SAC and to describe the radiographic and computed tomographic (CT) anatomy of normal teeth at different ages. In this study, the heads of 20 healthy SAC slaughtered for meat production or euthanized for reasons not related to dental problems included 7 female and 10 male llamas and 3 male alpacas. Using a standardized protocol, radiographs and CT scans of the 20 specimen were performed. RESULTS The most useful radiographic projections for mandibular and maxillary cheek teeth evaluation turned out to be lateral30°ventral-laterodorsal and lateral30°dorsal-lateroventral with slight separation of the dental arcades respectively. Digital radiographic and CT appearance of the mandibular and maxillary teeth were described from the beginning of mineralization till maturity. In addition the normal range of the CT radio density of different cheek teeth and different dental tissues were measured. Hounsfield units of different dental tissues of SAC turned out to be similar to equids. Deviation, shortening and partial destruction of the distal tooth root of mandibular 09's and 10's and of maxillary 09's was observed and the existence of a common pulp chamber in younger teeth was revealed. CONCLUSIONS The present study provides information about the dental imaging morphology in clinically healthy SAC. This basic information provides fundamental knowledge for evaluating images and planning treatments in clinically affected animals.
Resumo:
OBJECTIVES This study analyses the changes in smoking habits over the course of 1 year in a group of patients referred to an oral medicine unit. MATERIALS AND METHODS Smoking history and behaviour were analysed at baseline and after 1 year based on a self-reported questionnaire and on exhaled carbon monoxide levels [in parts per million (ppm)]. During the initial examination, all smokers underwent tobacco use prevention and cessation counselling. RESULTS Of the initial group of 121 patients, 98 were examined at the follow-up visit. At the baseline examination, 33 patients (33.67 %) indicated that they were current smokers. One year later, 14 patients (42.24 % out of the 33 smokers of the initial examination) indicated that they had attempted to stop smoking at least once over the follow-up period and 15.15 % (5 patients) had quit smoking. The mean number of cigarettes smoked per day by current smokers decreased from 13.10 to 12.18 (p = 0.04). The exhaled CO level measurements showed very good correlation with a Spearman's coefficient 0.9880 for the initial visit, and 0.9909 for the follow-up examination. For current smokers, the consumption of one additional cigarette per day elevated the CO measurements by 0.77 ppm (p < 0.0001) at the baseline examination and by 0.84 ppm (p < 0.0001) at the 1-year follow-up. CONCLUSIONS In oral health care, where smoking cessation is an important aspect of the treatment strategy, the measurement of exhaled carbon monoxide shows a very good correlation with a self-reported smoking habit. CLINICAL RELEVANCE Measurement of exhaled carbon monoxide is a non-invasive, simple and objective measurement technique for documenting and monitoring smoking cessation and reduction.
Resumo:
OBJECTIVE The Short Communication presents a clinical case in which a novel procedure--the "Individualized Scanbody Technique" (IST)--was applied, starting with an intraoral digital impression and using CAD/CAM process for fabrication of ceramic reconstructions in bone level implants. MATERIAL AND METHODS A standardized scanbody was individually modified in accordance with the created emergence profile of the provisional implant-supported restoration. Due to the specific adaptation of the scanbody, the conditioned supra-implant soft tissue complex was stabilized for the intraoral optical scan process. Then, the implant platform position and the supra-implant mucosa outline were transferred into the three-dimensional data set with a digital impression system. Within the technical workflow, the ZrO2 -implant-abutment substructure could be designed virtually with predictable margins of the supra-implant mucosa. RESULTS After finalization of the 1-piece screw-retained full ceramic implant crown, the restoration demonstrated an appealing treatment outcome with harmonious soft tissue architecture. CONCLUSIONS The IST facilitates a simple and fast approach for a supra-implant mucosal outline transfer in the digital workflow. Moreover, the IST closes the interfaces in the full digital pathway.